![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
CLL Series Photo-IC Sensors Digital Output 0.500(12.7) min. 0.500(12.7) min. 0.157 (3.99) 0.210 (5.33) 0.137 (3.48) 0.210 (5.33) 0.190 (4.83) 0.190 (4.83) 0.187 (4.75) 0.187 (4.75) 0.179 0.179 (4.55) (4.55) 1. OUTPUT 1. OUTPUT 2. VCC 2. VCC 4 (R) Clairex Technologies, Inc. March, 2003 3. GROUND 3. GROUND 4. ADJUST 4. ADJUST 0.048 (1.22) 0.048 (1.22) 0.028 (0.71) 0.028 (0.71) 0.046 (1.17) 0.046 (1.17) 0.036 (0.91) 0.036 (0.91) 4 3 TO-72 CLL130 CLL131 CLL133 3 22 11 0.030 (0.76) max. 0.030 (0.76) max. 0.060 (1.52) 0.060 (1.52) max max 0.230 (5.84) 0.230 (5.84) 0.209 (5.31) 0.209 (5.31) 45 45 Case 21 1. OUTPUT 0.500(12.7) min. 0.210 (5.33) 0.190 (4.83) 4 3 0.187 (4.75) 0.179 (4.55) 2 1 0.030 (0.76) max. 0.010 (0.25) max 0.046 (1.17) 0.036 (0.91) 0.230 (5.84) 0.209 (5.31) 0.048 (1.22) 0.028 (0.71) 2. VCC 3. GROUND 4. ADJUST TO-72 CLL130W CLL131W CLL133W 45 Case 22 1. OUTPUT 0.500(12.7) min. 3. GROUND 4. ADJUST features * Output stages: a. Buffer or inverter b. Open collector or internal 10K pull-up * Supply voltage 4.5V to 18V * 7:1 user sensitivity adjustment on CLL130-CLL133 and CLL130W-CLL133W series * Acceptance angle: a. 15 high dome lens can b. 35 flat window lens can * Operates to 125C * RoHS compliant description The CLL series are monolithic integrated circuits incorporating a photodiode, linear amplifier, Schmitt trigger for hysteresis and pulse shaping, and digital output with either 10K pull-up or open collector. The series includes TO-72 four leaded packages (with user adjustable gain) and TO-18 three leaded packages in both high dome and flat window configurations. Alternate pin-outs are available. Contact Clairex. 0.210 (5.33) 0.190 (4.83) 2. VCC 4 3 0.187 (4.75) 0.179 (4.55) 0.048 (1.22) 0.028 (0.71) TO-18 CLL134 CLL135 CLL136 CLL137 2 1 0.030 (0.76) max. 0.060 (1.52) max 0.046 (1.17) 0.036 (0.91) 0.230 (5.84) 0.209 (5.31) 45 Case 21 1. OUTPUT 0.500(12.7) min. 0.210 (5.33) 0.190 (4.83) 4 3 0.187 (4.75) 0.179 (4.55) 2 1 0.030 (0.76) max. 0.010 (0.25) max 0.046 (1.17) 0.036 (0.91) 0.230 (5.84) 0.209 (5.31) 0.048 (1.22) 0.028 (0.71) 2. VCC 3. GROUND 4. ADJUST TO-18 CLL134W CLL135W CLL136W CLL137W 45 Case 22 ALL DIMENSIONS ARE IN INCHES (MILLIMETERS) Revised 3/16/06 Page 1 of 4 Clairex reserves the right to make changes at any time to improve design and to provide the best possible product. Clairex Technologies, Inc. Phone: 972-265-4900 1301 East Plano Parkway Fax: 972-265-4949 Plano, Texas 75074-8524 www.clairex.com CLL Series Photo-IC Sensors Digital Output Schematics VREG ADJ VCC VOUT LA LA VREG (R) Clairex Technologies, Inc. VCC VOUT GND CLL133/CLL133W Open collector - inverter with Adjust CLL135/CLL135W Open collector - inverter GND VREG ADJ 10k VCC VOUT VREG VCC VOUT LA LA GND CLL131/CLL131W 10k pull-up - inverter with Adjust VREG VCC VOUT LA GND CLL134/CLL134W Open collector - buffer VREG 10k VCC VOUT LA ADJ 10k GND CLL130/CLL130W 10k pull-up - buffer with Adjust GND CLL137/CLL137W 10k pull-up - inverter VREG 10k VCC VOUT LA GND CLL136/CLL136W 10k pull-up - buffer Clairex reserves the right to make changes at any time to improve design and to provide the best possible product. Page 2 of 4 Clairex Technologies, Inc. Phone: 972-265-4900 1301 East Plano Parkway Fax: 972-265-4949 Plano, Texas 75074-8524 www.clairex.com CLL Series Photo-IC Sensors Digital Output Absolute maximum ratings (TA = 25C unless otherwise stated) (R) Clairex Technologies, Inc. storage temperature ........................................................................................................ -65C to +150C operating temperature ..................................................................................................... -65C to +125C lead soldering temperature(1) ............................................................................................................260C VCC supply voltage...................................................................................................................4.5V to 18V VADJ (CLL130-CLL133 and CLL130W-CLL133W only) ......................................................................... 3V VOUT (10k pull-up series)(2) ................................................................................................................ 18V VOUT (open collector series)(2) .............................................................................................................. 30V ISINK(3) ................................................................................................................................................ 25mA continuous power dissipation(4) ..................................................................................................... 250mW NOTES: 1. 1/16" from the case for 5 seconds maximum. 2. This rating applies when the output is in the OFF state only. 3. This rating applies when the output is in the ON state only. 4. Derate linearly 2.0mW/C from 25C free air to TA = 125C. 5. CLL130-CLL133 and CLL130W-CLL133W photo-IC sensors are tested with the ADJ lead open. 6. Light source is an AlGaAs IRED with peak wavelength at 850nm. DEFINITIONS: * Ee (+) is the minimum irradiance required to cause the output to change state. * Buffer: Output is HIGH when input irradiance is >Ee (+). * Inverter: Output is LOW when input irradiance is >Ee (+). electrical characteristics (TA = 25C unless otherwise noted) parameter Operating supply voltage Positive going threshold irradiance(6) Hysteresis ratio Supply current Total acceptance angle symbol VCC Ee (+) EeT (+) EeT (-) ICC P min 4.5 0.005 0.025 1.1 typ 30 70 max 18 0.05 0.25 1.8 12 mA deg. deg. units V mW/cm2 mW/cm2 test conditions 4.5V VCC 18V, ADJ open, All non-suffix W parts. All suffix W parts. operate point/release point 4.5V VCC 18V, Ee = 0 or 0.5mW, ADJ open All non-suffix W parts All suffix W parts Gain threshold can be adjusted on the CLL130-CLL133 and CLL130W-CLL133W series by placing a resistor between the ADJ and GND leads in accordance with the following table. Decreasing the resistance causes the output to switch at a higher threshold level. ADJ Resistor open 10k 4.7k 2.2k 1k Connected to GND Normalized Threshold 1.00 2.00 2.75 3.75 5.00 7.25 Page 3 of 4 Clairex reserves the right to make changes at any time to improve design and to provide the best possible product. Clairex Technologies, Inc. Phone: 972-265-4900 1301 East Plano Parkway Fax: 972-265-4949 Plano, Texas 75074-8524 www.clairex.com CLL Series Photo-IC Sensors Digital Output electrical characteristics (TA = 25C unless otherwise noted) parameter symbol min typ CLL130/CLL130W and CLL136/CLL136W (buffer, 10k pull-up) High state output voltage Low state output voltage Output rise and fall time Propagation delay VOH VOL tr, tf tPHL, tPLH 4.5 75 5 max 0.4 0.4 100 0.4 units V V ns s V V ns s A V ns s (R) Clairex Technologies, Inc. test conditions VCC = 5.0V, Ee (+) 0.5mW/cm2 VCC = 5.0V, Ee (+) = 0 VCC = 5.0V, Ee = 0 or 0.5mW/cm2, f = 10kHz, D.C. = 50%, RL = 330 VCC = 5.0V, Ee (+) = 0 VCC = 5.0V, Ee (+) 0.5mW/cm2 VCC = 5.0V, Ee = 0 or 0.5mW/cm2, f = 10kHz, D.C. = 50%, RL = 330 VCC = 5.0V, VOH = 30V Ee (+) 0.5mW/cm2 VCC = 5.0V, Ee (+) = 0 RL = 330 VCC = 5.0V, Ee = 0 or 0.5mW/cm2, f = 10kHz, D.C. = 50%, RL = 330 VCC = 5.0V, VOH = 30V Ee (+) = 0 VCC = 5.0V, RL = 330 Ee (+) 0.5mW/cm2 VCC = 5.0V, Ee = 0 or 0.5mW/cm2, f = 10kHz, D.C. = 50%, RL = 330 CLL131/CLL131W and CLL137/CLL137W (inverter, 10k pull-up) High state output voltage VOH 4.5 Low state output voltage Output rise and fall time Propagation delay High state output current Low state output voltage Output rise and fall time Propagation delay VOL tr, tf tPHL, tPLH IOH VOL tr, tf tPHL, tPLH 75 5 75 5 CLL134/CLL134W (buffer, open collector) CLL133/CLL133W and CLL135/CLL135W (inverter, open collector) High state output current Low state output voltage Output rise and fall time Propagation delay IOH VOL tr, tf tPHL, tPLH 75 5 100 0.4 A V ns s NOTE: Due to the high sensitivity of the CLL series, when used in high speed switching applications, Clairex recommends installing a 0.1F capacitor between VCC and GND. Clairex reserves the right to make changes at any time to improve design and to provide the best possible product. Page 4 of 4 Clairex Technologies, Inc. Phone: 972-265-4900 1301 East Plano Parkway Fax: 972-265-4949 Plano, Texas 75074-8524 www.clairex.com |
Price & Availability of CLL131W
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |