If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Rast 5 Power Relay 419 01 2 pole 16 A, DC- and AC-coil Features * * * * * * Safety mains insulation Contact gap > 3 mm 4 kV / 8 mm coil-contact Ambient temperature up to 90C Faston connectors (DIN 46244) Snap or screw mounting Applications Industrial and domestic appliances, absolute safe power supply disconnection F0255-A VZH Contact data Configuration Type of contact Rated current Rated voltage / max.breaking voltage AC Maximum breaking capacity AC Make current (max. 4 s at duty cycle 10%) Contact material Contact gap Contact ratings Type Load DC-version 16 A, DC-version 12 A, AC-version 16 A, AC-version 12 A, 2 N/O contact single contact 16 A 250 Vac / 400 Vac 4000 VA 25 A AgCdO, AgNi >3 mm Operations 2.5x105 2.5x105 1x105 1x105 Technical data of approved types on request 250 Vac, 250 Vac, 250 Vac, 250 Vac, resistive resistive resistive resistive Coil data Nominal voltage Nominal coil power Operate category DC coil AC coil DC coil AC coil 6...24 Vdc 120...400 Vac 1.3 W 2.0...2.5 VA 2/c Coil versions, DC coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vdc Vdc Vdc Vdc c mA 31 12 7.7 0.9 19.5 118+10% 102.0 29 24 15.5 1.8 39.0 470+10% 51.0 Coil versions, AC coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vac, 50 Hz Vac Vac Vac c mA 14 110...120 93.0 18.0 132.0 1650+10% 20.0 10 220...240 187.0 36.0 264.0 6600+10% 10.0 09 380...400 323.0 60.0 440.0 20000+10% 6.0 All figures are given for coil without preenergization, at ambient temperature +20C Other coil voltages on request Edition: 11/2003 Rights to change data / design reserved Rast 5 Power Relay 419 01 2 pole 16 A, DC- and AC-coil Insulation Dielectric strength coil-contacts open contact circuit Clearance / creepage Insulation to IEC 60664 Voltage rating Pollution degree Overvoltage category Insulation to VDE 0110b (2/79) Insulation category / reference voltage Tracking resistance of relay base 4000 Vrms 2000 Vrms 8 / 8 mm 250 V 3 III C / 380 CTI 600M Other data Ambient temperature Mechanical life Max. switching rate at rated- / minimum load Operate- / release time Bounce time Vibration resistance Shock resistance (destruction) Category of protection (IEC 61810) Relay weight Packaging unit -20...+90 C >2x106 operations 15 min-1 / 600 min-1 typ. 15 / 15 ms typ. 4 ms 2 g, 5...500 Hz 80 g RT I - dust protected 90 g 42 pcs. Snap-on mount / Dimensions Dimensions in mm Terminal assignment S0447-AA Edition: 11/2003 Rights to change data / design reserved Rast 5 Power Relay 419 01 2 pole 16 A, DC- and AC-coil Screw mount / Dimensions Dimensions in mm Terminal assignment S0447-AB Edition: 11/2003 Rights to change data / design reserved |
Price & Availability of 041901100100
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |