 DC-DC Converter UNIT
MAU Series ( 1 W UNREGULATED DC-DC CONVERTER )
FEATURES
1000VDC ISOLATION EFFICIENCY UP TO 82% INTERNAL SMD TECHNOLOGY LOW COST NO HEATSINK REQUIRED UP TO 1W UNREGULATED OUTPUT POWER DUAL IN LINE PACKAGE 100% BURNED IN MTBF > 2,000,000 HOURS
OUTPUT SPECIFICATIONS
Voltage Setpoint Accuracy Temperature Coefficient Ripple & Noise (20MHz BW) Line Regulation
1
INPUT SPECIFICATIONS
+/-2% max +/-0.03%/ C
O
Input Voltage Range Input Filter
+/-10% max Capacitor Type
100mVp-p max +/-1.2% max +/-8% max Momentary
Load Regulation2 Short Circuit Protection
GENERAL SPECIFICATIONS
Efficiency Isolation Voltage
3
70%-82% 1000 VDC min 9 10 ohms min 100 KHz min 80pF max 2,000,000 Hours 1.7g Typ Non-Conductive Plastic 12.7mm*10.16mm*6.87mm
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Storage Temperature Cooling -25 OC to +71 OC -55 C to +125 C
O O
Isolation Resistance Switching Frequency Isolation Capacitance MTBF Weight
Free-Air Convection
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 OC UNLESS OTHERWISE NOTED.
Case Material Case Size
1 2 3
Line Regulation is for a 1.0% change in input Voltage. Load Regulation is for output load current change from 20% to 100%. For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MAU Series ( 1 W UNREGULATED DC-DC CONVERTER )
SELECTION GUIDE 1W OUTPUT
MODEL NUMBER INPUT (VDC)
5 5 5 5 12 12 12 12 24 24 24 24 48 48 48 48
OUTPUT (VDC)
5 9 12 15 5 9 12 15 5 9 12 15 5 9 12 15
OUTPUT (mA)
200 110 84 67 200 110 84 67 200 110 84 67 200 110 84 67
INPUT CURRENT(mA)
FULL LOAD NO LOAD 26 27 26 28 11 11 11 12 8 8 8 7 4 4 4 4 77 77 79 79 78 79 82 82 77 77 77 80 76 77 77 79 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
VOLTAGE VOLTAGE CURRENT
EFF (%)
ISOLATION (VDC)
MAUS-0505 MAUS-0509 MAUS-0512 MAUS-0515 MAUS-1205 MAUS-1209 MAUS-1212 MAUS-1215 MAUS-2405 MAUS-2409 MAUS-2412 MAUS-2415 MAUS-4805 MAUS-4809 MAUS-4812 MAUS-4815
260 260 253 253 107 105 102 102 54 54 54 52 27 27 27 26
Note: Other input to output voltages may be available. Please contact factory.
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MAU Series ( 1 W UNREGULATED DC-DC CONVERTER )
MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS
PIN 1 4 5 7
SINGLE -Vin +Vin +Vout -Vout
SIMPLIFIED SCHEMATIC
TYPICAL APPLICATIONS
INPUT OUTPUT
+Vin +Vout
+Vin
OSCILLATOR DRIVER
+Vout
-Vin
-Vout
DC-DC CONVERTER
-Vin -Vout
LOAD
www.Power-Systems.de
Page: 3 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MAU Series ( 1 W UNREGULATED DC-DC CONVERTER )
TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC , nominal input voltage , rated output current unless otherwise specified.
VOUT VS LOAD(5Vout Models)
6.4 6.0 5.6 5.2 4.8 0 50 100 150 200
VOUT VS LOAD(9Vout Models)
10.4 10.0 9.6 9.2 8.8 0 28 56 84 111
Vout(V)
Vout(V)
Output Current(mA)
Output Current(mA)
VOUT VS LOAD(12Vout Models)
13.5 13.0
VOUT VS LOAD(15Vout Models)
16.5 16.0
Vout(V)
12.5 12.0 11.5 0 20 40 60 80
Vout(V)
15.5 15.0 14.5 0 15 30 45 60
Output Current(mA)
Output Current(mA)
EFFICIENCY VS LOAD
OUTPUT POWER(W) EFFICIENCY(%)
80.0 60.0 40.0 20.0 0.0 0 20 40 60 80 100 1.2 0.9 0.6 0.3 0.0
DERATING CURVE
SAFE OPERATING AREA
-25 0 25 50 70 100
% OF RATED LOAD(%)
TA(degree C)
www.Power-Systems.de
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
MAU Series ( 1 W UNREGULATED DC-DC CONVERTER )
MAU SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS: Output filtering is required for operation. A minimum of 10uF is needed. Output capacitance may be increased for additional filtering, not to exceed 220uF. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 250KHz is required. Negative Outputs: A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting -OUT as the negative output.
FOR MORE INFORMATION CALL: Power Systems - The Power Solution
Ilsfeld-Auenstein ( Germany ) Dornet 8 E-mail: Info@Power-Systems.de Tel: + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 -80 Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Version: 4-Oct-02


▲Up To Search▲   

 
Price & Availability of MAUS-0505

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X