![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
300W Single Output with PFC Function Features : HRP-300 series Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% (typ.) Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Built-in constant current limiting circuit 1U low profile 41mm Built-in cooling fan ON-OFF control With DC OK signal output Built-in remote sense function 5 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE HRP-300-3.3 3.3V 60A 0 ~ 60A 198W HRP-300-5 5V 60A 0 ~ 60A 300W 90mVp-p 4.3 ~ 5.8V 2.0% 0.5% 1.0% HRP-300-7.5 7.5V 40A 0 ~ 40A 300W 100mVp-p 6.8 ~ 9V 2.0% 0.5% 1.0% HRP-300-12 12V 27A 0 ~ 27A 324W 120mVp-p 10.2 ~ 13.8V 1.0% 0.3% 0.5% HRP-300-15 15V 22A 0 ~ 22A 330W 150mVp-p 13.5 ~ 18V 1.0% 0.3% 0.5% HRP-300-24 24V 14A 0 ~ 14A 336W 150mVp-p 21.6 ~ 28.8V 1.0% 0.2% 0.5% HRP-300-36 36V 9A 0 ~ 9A 324W 250mVp-p 28.8 ~ 39.6V 1.0% 0.2% 0.5% HRP-300-48 48V 7A 0 ~ 7A 336W 250mVp-p 40.8 ~ 55.2V 1.0% 0.2% 0.5% RIPPLE & NOISE (max.) Note.2 80mVp-p 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.5% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) 0.5% 1.0% 16ms/230VAC 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load 16ms/115VAC at full load 120 ~ 370VDC PF>0.99/115VAC at full load 86% 88% 88% 87% 88% 89% VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVER VOLTAGE PF>0.95/230VAC 80% 5A/115VAC 35A/115VAC 82% 2.5A/230VAC 70A/230VAC <1.2mA / 240VAC 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover 90 5 5 (TSW1: detect on heatsink of power transistor) for 3.3V,5V,7.5V ; 95 5 for others (TSW2: detect on heatsink of power diod e) 100 41.4 ~ 48.6V 57.6 ~ 67.2V PROTECTION OVER TEMPERATURE DC OK SIGNAL FAN CONTROL (Typ.) WORKING TEMP. FUNCTION Protection type : Shut down o/p voltage, recovers automatically after temperature goes down PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V Load 35 15% or RTH2 -30 ~ +70 50 Fan on (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY MTBF I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A 176K hrs min. MIL-HDBK-217F (25 ) 199*105*41mm (L*W*H) 0.95Kg;15pcs/15.3Kg/0.69CUFT OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:HRP-300-SPEC 2009-11-09 300W Single Output with PFC Function Mechanical Specification HRP-300 Case No.980A 18 12.5 series Unit:mm 4-M4 L=6 168.5 168.5 R2 .25 12.25 199 168.5 12.25 42.5 120 1.5 HOLE IN CHASSIS 4.5 18 1 11 2 3 4 5 6 7 LED CN100 SVR 4-M4 L=5 Terminal Pin No. Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Assignment Pin No. DC OUTPUT -V 4,5 6,7 DC OUTPUT +V Connector Pin No. Assignment (CN100) : HRS DF11-08DP-2DS or equivalent Pin No. Assignment 1,2,4,6 NC DC-OK 3 5 GND +S 7 -S 8 Mating Housing Terminal 17max. 167.5 167.5 12.25 12.25 4-M4 L=6 Block Diagram I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC O.T.P. POWER SWITCHING O.L.P. PWM CONTROL RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. FG PFC CONTROL Derating Curve Output Derating VS Input Voltage Ta = 25 100 100 90 80 80 70 60 LOAD (%) 50 40 LOAD(%) 60 50 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:HRP-300-SPEC 2009-11-09 12.5 18 41 HRS DF11-8DS or equivalent HRS DF11-**SC or equivalent 15 75 105 125 9.2 FAN Air flow direction 17 28 fosc : 70KHz +S +V -V -S DC OK 264 |
Price & Availability of HRP-300-12
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |