![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
(R) assuredcommunications (R) RF-5051-PS001 RF-5054-PS001 AC POWER SUPPLIES fully compatible and functional members of the FALCON(R) Series RF-5000 and FALCON(R) II RF-5800H tactical Communications families The RF 5051 PS001and RF 5054 PS001 Series of high performance AC power supplies allows operation of Fallon(R) II/Falcon(R)III and RF 5000 Series systems from a VAC input range of 85 to 265 volts in base station, shipboard, or transportable applications. The RF 5051 PS001 Power Supply provides 28 volts DC at 30 Amps to power up to 840 watts. The power supply uses the same mounting as the RF 5022R/T(E) Receiver/Exciter and is compatible with RF 5000 and RF 5800H family shock mounts and transport packages. RF 5051 PS001 environment specifications match those (R) of the FALCON family components, providing a system which is reliable even under the harshest of conditions. The RF 5054 PS001 Power Supply consists of two RF 5051 PS001 units connected in parallel. The RF 5054 PS001 provides power for 400 watt Falcon Series systems. The RF 5051 PS001has backward compatible functionality to the RF 5051PS 125, and both RF 5051 PS001 and RF 5051PS 125 may be combined to create an RF 5054 PS001. Specifications for the RF-5051-PS001 and RF-5054-PS001 General/Electrical Input Voltage 85 265 VAC, 47 400 Hz Input Power Factor Correction >95% (85 265 VAC) Input Protection Circuit Breaker Output Voltage +28 VDC + 0.5 _ Regulation, Line Load 0.2% from low line to high line Ripple and Noise 200 MV @ 30A Voltage Stability 200 MV drift maximum Efficiency >80% Over Voltage Protection Set to 28 + 0.5 VAC _ Output Current RF 5051 PS001: 30 Amps maximum RF 5054 PS001: 60 Amps maximum Inrush Current RF 5051 PS001: 4 Amps for 10 ms RF 5054 PS001: 8 Amps for 10 ms Hold Time RF 5051 PS001: 500 ms with 0.5 Amp load RF 5054 PS001: 1 sec. with 0.5 Amp load Overload Protection RF 5051 PS001: Out. current limit 33 Amps RF 5054 PS001: Out. current limit 66 Amps Output Protection Output is automatically protected from short and misfirting Mechanical/Environmental Cooling Conduction to outside heat sink, forced convection Temperature Operating: - 40Cto +70C; Storage: - 60C to +90C Altitude MIL STD 810F Humidity MIL STD 810F, 95% Shock/Vibration MIL STD 810F EMI MIL STD 461E Size RF 5051 PS001: 5.5H x 7.5W x 12.8D in (14H x 19.1W x 32.5D cm) RF 5054 PS001: 5.5H x 15.0W x 12.8D in (14H x 38.1W x 32.5D cm) Weight RF 5051 PS001: 17.3 lb (7.8 kg) RF 5054 PS001: 34.6 lb (15.7 kg) Features/Benefits High reliability Configurations for 50, 125 and 400 watt systems Conservative ratings Rugged package compatible with the FALCON(R) Series RF 5000 and FALCON(R) II RF 5800H Tactical Transceiver Systems Ground Fault Interrupters CISPR221EN55022 Level B Allows Generator Operation Supports Line/Line Operation Self Fault Recovery Fault Indicator Specifications are subject to change without notice. (R) RF Communications Division | 1680 University Avenue | Rochester, NY USA 14610 www.harris.com 585 244 5830 Copyright (c) 2007 Harris Corporation 05/07 DS-223C assuredcommunications (R) |
Price & Availability of RF-5054-PS001
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |