![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AC-DC 125 Watts IFC125 Series * * * * * * * Small Size - 3.0" x 5.0" x 1.25" xppower.com Single, Triple and Quad Outputs Active PFC - Meets EN61000-3-2, -3 Current Share up to 4 Units Overvoltage & Overcurrent Protection Power Good Signal -25 C to +50 C Full Power Specification Input Input Voltage Input Frequency Input Current * 90-264 VAC * 47-63 Hz * 0.8 A max at 240 VAC 1.8 A max at 100 VAC Inrush Current * 33 A max at 115 VAC 66 A max at 230 VAC Power Factor * 0.98 typical Earth Leakage Current * 0.5 mA max at 132 VAC/60Hz 0.825 mA max at 264 VAC/50Hz Input Protection * Internal 2.6 A fuse General Efficiency Isolation * 83% typical * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * 6.66 W/In3 * Power Good - On = Logic High * >220 kHrs per Bellcore Power Density Signals MTBF Environmental Operating Temperature * -25 C to +70 C, derate linearly from 100% at +50 C to 50% at +70 C Cooling * 5 CFM airflow required for 125 W Operating Humidity * 5-95% RH, non-condensing Storage Temperature * -40 C to +85 C Operating Altitude * 3000 m Shock * 15 G pk operating Vibration * 2.4 G, 5 Hz to 500 Hz, 3 axis Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Over/Undershoot Transient Response Ripple & Noise Overvoltage Protection Overtemperature Protection Overload Protection Short Circuit Protection Temperature Coefficient Remote Sense Current Share * * * * * * * * * * * * * * See table Not user-adjustable 5% maximum 5 W minimum load on V1 or V2 required to maintain regulation 1.5 s at 90 VAC 0.2-20 ms >28 ms min at full load See table See table 10% maximum 5% max. deviation, recovery to within 1% in 500 s for a 25% load change 1% pk-pk maximum or 5 Vout 50 mV maximum V1 & V2: 113-148%, auto recovery Unit shuts down, recycle input to reset EMC & Safety Emissions Harmonic Currents Voltage Flicker Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals * EN55022/CISPR22 and FCC, Class B conducted * EN61000-3-2 * EN61000-3-3 * EN61000-4-3, level 3 Perf Criteria B * EN61000-4-4, level 3 Perf Criteria B * EN61000-4-5, level 3 Perf Criteria B * EN61000-4-6 * EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Criteria A, B, B * EN60950, UL 60950, CSA950 per cUL, CE Mark LVD * All outputs: 115-135%, auto recovery * Trip and restart (Hiccup mode) * 0.04% / C maximum * V1 only compensates for 0.5 V drop (not available on IFC125-31) * Up to 4 supplies to share within 10% 1 AC-DC Models and Ratings Vnom 24.0 V 5.0 V 2.5 V 3.3 V Notes 1. 2. 3. 4. IFC125 Output 2 Imax 0.5 A 5.0 A 15.0 A 15.0 A Reg(1) 5% 5% 4% 4% Vnom -12.0 V 12.0 V 12.0 V Output 3 Imax 0.5 A 5.0 A 5.0 A Reg(1) 5% 5% 5% Vnom Output 4 Imax Reg(1) Model Number IFC125-14 IFC125-31 IFC125-40-1 IFC125-42-3 Output 1 Imax 5.2 A 16.5 A 12.5 A 10.0 A Reg(1) 3% 4% 2% 2% Vnom 12.0 V 12.0 V 5.0 V 5.0 V -12.0 V -12.0 V 0.5 A 0.5 A 5% 5% Total regulation includes tolerance, line regulation and load regulation. Maximum output power not to exceed 125W with 5 CFM forced air or 70W with convection cooling. For IFC125-40-1 and -42-3, a maximum of 80W combined +2.5V or +3.3V and +5V outputs with 5CFM of forced air cooling or 40W with convection cooling. 5W minimum load required to maintain regulation. Mechanical Details Connector Pin-outs Conn Pin IFC125-31 IFC125-40-1 IFC125-42-3 1 Neutral Neutral Neutral J1 2 3 Line Line Line 1 -12 VDC -12 VDC -12 VDC 2 +12 VDC +12 VDC +12 VDC 3 Not Used +2.5 VDC +3.3 VDC 4 Not Used +2.5 VDC +3.3 VDC 5 Not Used +2.5 VDC +3.3 VDC 6 DC GND DC GND DC GND 7 DC GND DC GND DC GND J2 8 DC GND DC GND DC GND 9 DC GND DC GND DC GND 10 DC GND DC GND DC GND 11 +5 VDC +5 VDC +5 VDC 12 +5 VDC +5 VDC +5 VDC 13 +5 VDC +5 VDC +5 VDC 14 +5 VDC +5 VDC +5 VDC 1 0 V Sense 0 V Sense 0 V Sense J3 2 Not Used +2.5 V Sense +3.3 V Sense 3 Power Good Power Good Power Good 5.00 (127.0) 0.23 (5.7) 4.55 (115.6) O 0.16 (4.1) (4 places) 3.00 (76.2) 2.55 (64.8) Pin #1 J1 - Input connector Safety ground connection point Pin #1 J2 - DC output connector for IFC125-31, -40-1, 42-3. (see pin-out table) Pin #1 J3 - Remote Sense/ PG connector Fastener clearance area (4 places) Lock washer Screws shown for reference only 1.00 1.25 (25.4) (31.8) 0.06 (1.5) 0.19 (4.8) PCB Molex Mating Connectors IFC125-31 & -40-1 J1 Housing Pins Housing Pins Housing Pins 09-50-8031 08-52-0113 09-50-8141 08-52-0113 22-01-3037 08-50-0114 IFC125-42-3 90-50-8033 08-52-0113 09-50-8143 08-52-0113 22-01-3037 08-50-0114 Notes 1. All dimensions in inches (mm). 2. Weight 0.68 lb (310 g) approx (-14 models 0.6 lb, 270g). J2 J3 16-Aug-05 |
Price & Availability of IFC125-14
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |