|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AC-DC 120-480 Watts DNR120-480 Series * * * * * * * Up to 90% Efficiency Wide Adjustment Range Three-phase 480 W Versions Parallel Function DC Standby Versions Full Power to +60 C Connector Options xppower.com Specification Input Input Voltage * DNR120LS: 93-132/186-264 VAC switch select, 210-370 VDC switch in 230 VAC position DNR120AS: 90-132/186-264 VAC auto select, 210-370 VDC DNR240PS: 93-132/186-264 VAC, auto select, 210-370 VDC DNR480PS: 90-264 VAC, 120-370 VDC DNR480TS: 340-575 VAC 3O, 480-820 VDC Input Frequency * 47-63 Hz Inrush Current * 120 W: 24/48 A at 115/230 VAC 240 W: 30/60 A at 115/230 VAC 480PS: 25/50 A at 115/230 VAC 480TS: 33 A at 575 VAC Power Factor * Meets EN61000-3-2 for class A equipment Earth Leakage Current * 0.8 mA max General Efficiency Isolation * See tables * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * 100 KHz typical * DC ON indicator LED Green, DC LOW indicator LED Red DC OK: 24 V models * 200 kHrs typical per MIL-HDBK-217F GF, +40 C Switching Frequency Signals MTBF Environmental Operating Temperature * DNR120-240: -10 C to +70 C, derate linearly from +60 C at 2.5%/C DNR480 PS: -25 C to +70 C, derate linearly from +55 C at 2.5%/C DNR480 TS: -25 C to +70 C, derate linearly from +60 C at 2.5%/C. (see derating curves) Cooling * Convection-cooled Operating Humidity * 20-95% RH, non-condensing Storage Temperature * -25 C to +85 C Shock * 4 g, 22 ms, X, Y & Z axis Vibration * 1 g, 10 Hz to 500 kHz, along X, Y & Z axis Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time * * * * * * * See tables See tables 1% No minimum load required <1000 ms <150 ms 120 & 240 W: 25/30 ms at 115/230 VAC 480PS: 30 ms at 115/230 VAC 480TS: 20 ms at 340 VAC 0.5% max (1% max for 480TS) 1% (5% for units in parallel), 120LS models - see note 1 300 s for a 50% load change 120 W models: 50 mV pk-pk 240-480 W models: 100 mV pk-pk. 20 MHz BW Output clamps at 125-145% Vnom 105-145% constant current. 480TS model: 115-135% continuous power limit, Imax = 2 x Inom at short circuit condition or switchable trip and restart mode, output is turned on for 3 s every 30 s. 0.02%/C EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions EN55022, class B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, level 3 Perf Criteria A EN61000-4-3, level 3 Perf Criteria A EN61000-4-4, level 3 Perf Criteria A EN61000-4-5, level 3 Perf Criteria A EN61000-4-6, level 3 Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B * EN60950-1:2001, UL508, UL60950-1, cUL60950-1, CE Mark * * * * * * * * * Line Regulation Load Regulation Transient Response Ripple & Noise * * * * Overvoltage Protection * Overload Protection * Safety Approvals Temperature Coefficient * AC-DC Models and Ratings Output Voltage 12 V 24 V 48 V 12 V 24 V 48 V 24 V 48 V 24 V 48 V 24 V 48 V Notes Output Voltage Trim 11.4-14.5 V 22.5-30.0 V 45.0-55.0 V 11.4-14.5 V 22.5-30.0 V 45.0-55.0 V 22.5-28.5 V 47.0-56.0 V 22.5-28.5 V 47.0-56.0 V 22.5-28.5 V 47.0-56.0 V Output Current 10.0 A 5.0 A 2.5 A 10.0 A 5.0 A 2.5 A 10.0 A 5.0 A 20.0 A 10.0 A 20.0 A 10.0 A DNR120-480 Typical Efficiency 84% 86% 87% 84% 86% 87% 89% 90% 89% 90% 88% 89% Model Number DNR120LS12(1,2,3) DNR120LS24(1,2,3) DNR120LS48(1,2,3) DNR120AS12-I(3,4) DNR120AS24-I(3,4) DNR120AS48-I(3,4) DNR240PS24-I(3,4) DNR240PS48-I(3,4) DNR480PS24-I(3,4) DNR480PS48-I(3,4) DNR480TS24-I DNR480TS48-I 1. Add suffix `-I' to DNR120LS model number for parallel function, (120AS, 240 & 480 W models have parallel function as standard). A maximum of 3 units can be paralleled. Total power available is 90% of the rated current of each unit. 2. For PFC version of DNR120LS, replace `L' in the model number with `P' e.g. DNR120LS24 becomes DNR120PS24 (Typical power factor 0.7). 3. Add suffix `-D' for detachable connector option. 4. For DC standby, remove `-I' and add # to the end of the model number. Available from Farnell. See pages 204-206. Derating Curves DNR120-240 DNR120 & 240 DNR120 & 240 100 80 Load (%) DNR480PS DNR480PS DNR480PS 100 80 Load (%) DNR480TS DNR480PS 100 80 Load (%) Load (%) DNR120 & 240 100 80 DNR480TS DNR480TS 100 80 Load (%) DNR480TS 100 80 100 80 Load (%) 100 80 60 40 20 0 -10 10 40 20 40 20 0 30 10-10 Load (%) 60 Load (%) 60 60 40 20 0 60 40 20 0 -25 -10 -200 60 40 20 0 60 40 20 60 40 20 0 -25 -10 -200 0 0 -10 10 0 20 20 40 0 30 10 50 40 20 60 50 30 70 60 40 70 50 60 70 -25 -20 -10 10 40 020 -20 30 -1020 -25 10 40 50 60 030 10 60 20 70 30 50 40 70 50 60 0 70 -25 -20 20 020 -20 30 -10 40 -25 10 40 50 60 50 030 10 60 20 70 30 40 70 50 60 Ambient Temp (C) Ambient Temp (C) Ambient Temp (C) Ambient Temp (C) Ambient Temp (C) Ambient Temp (C) Ambient Temp (C) Ambient Temp (C) Ambient Temp (C) Standby Versions + + DC OK DC OK DC LO ON K1 6 1 Output Set Voltages For Standby Versions Model DNR120AS12# D1 K1 Fuse LOAD Voltage 13.6 V 27.2 V 54.5 V 27.2 V 54.5 V 27.2 V 54.5 V Current 8.8 A 4.4 A 2.2 A 8.8 A 4.4 A 17.6 A 8.8 A DC OK Shutoff 10.8 V 5% 21.6 V 5% 43.2 V 5% 21.6 V 5% 43.2 V 5% 21.6 V 5% 43.2 V 5% DNR120AS24# DNR120AS48# DNR240PS24# RL > 700ohm DCOK - Battery 22K DCOK 0.5W DNR240PS48# DNR480PS24# DNR480PS48# 1 3 -Vout 5.1K 0.3W Maximum current drain from battery by PSU when inactive 22 mA. -Vout a) Relay Example b) 5 V Signal Example - DC OK Volt free contact closed when good voltage from PSU or battery available to the load in standby system Available on 24 V models only. DCOK Open = Output fail Closed = Output good DCOK Contact Rating: 0.3 A at 60 VDC 500 VDC isolation AC-DC Mechanical Details DNR120-480 DC Output 4.57 (116.0) 1 DNR120LS Models DC Output 6 1 6 0.39 (10.0) DC LO ON DC LO ON 4.92 (125.0) 5.59 (142.0) `-D' option 115 VAC 230 VAC 115 VAC 230 VAC 1 3 1 AC Input 3 AC Input 2.50 (63.5) DNR120 Connections Pin Designation 1 Ground AC 2 Line Input 3 Neutral 1 DC OK * 2 DC OK * DC 3 Positive 4 Positive Output 5 Negative 6 Negative Conn Notes 1. All dimensions in inches (mm). 2. Weight 1.4 lb (630 g) approx. 3. Screw terminal: 10-24AWG cable size. Detachable connector version: 14-24AWG cable size. * 24 V & standby models only. DNR120AS Models 240 W Models DC Output DC Output 6 Single Parallel 4.57 (116.0) 1 0.39 (10.0) 6 1 Single Parallel DC LO ON DC LO ON 4.92 (125.0) 5.59 (142.0) `-D' option 1 3 1 AC Input 3 AC Input 2.50 (63.5) DNR120 Connections Pin Designation 1 Ground AC 2 Line Input 3 Neutral 1 DC OK * 2 DC OK * DC 3 Positive 4 Positive Output 5 Negative 6 Negative Conn Notes 1. All dimensions in inches (mm). 2. Weight 1.4 lb (630 g) approx. 3. Screw terminal: 10-24AWG cable size. Detachable connector version: 14-24AWG cable size. * 24 V & standby models only. AC-DC Mechanical Details DNR120-480 4.57 (116.0) 6 1 240 W Models DC Output 6 Single Parallel 0.39 (10.0) 1 DC Output Single Parallel DC LO ON DC LO ON 4.92 (125.0) 5.59 (142.0) `-D' option 1 3 1 AC Input 3 AC Input 3.27 (83.0) Notes 1. All dimensions in inches (mm). 2. Weight 3.0 lb (1360 g) approx. The 14-24AWG cable size. 3. Screw terminal: 10-24AWG cable size. Detachable connector version:red LED is lit if the output voltage is 70-90% of VNOM DNR240 Connections Pin Designation 1 Ground AC 2 Line Input 3 Neutral 1 DC OK* 2 DC OK* DC 3 Positive 4 Positive Output 5 Negative 6 Negative Conn * 24 V & standby models only. 480 240 W Models The green LED is lit if the output voltage is >75% of VNOM A C 0.3 (7.0) B D DC ON DC LO AC Input 1 3 Optional detachable connector (`-D' option) DC Output 1 6 `PS' version AC Input 1 4 DC OK DC LO DC ON DC Output 1 4 `TS' version Notes 1. All dimensions in inches (mm). 2. Weight 4.2 lb (1920 g) approx. 3. Screw terminal: 10-24AWG cable size. Detachable connector version: 14-24AWG cable size. Single/parallel & current limit selector switches on underside A B C D DNR480 Dimensions 480PS 480TS 6.89 (175.0) 5.91 (150.0) 4.92 (125.0) 4.87 (123.6) 4.57 (116.0) 4.38 (111.3) 5.59 (142.0) DNR480PS Connections Conn Pin Designation 1 Ground AC 2 Neutral Input 3 Line 1 DC OK* 2 DC OK* DC 3 Positive 4 Positive Output 5 Negative 6 Negative * 24 V and standby models only. DNR480TS Connections Conn Pin Designation 1 Ground AC 2 L1 3 L2 Input 4 L3 1 Positive DC 2 Positive 3 Negative Output 4 Negative 1 DC OK* DC OK 2 DC OK* 09-Oct-07 |
Price & Availability of DNR240PS24 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |