 3000W Single Output Power Supply
Features :
RSP-3000
series
AC input active surge current limiting High efficiency up to 90% Built-in active PFC function,PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature / Fan Alarm Forced air cooling by built-in DC with fan speed control function Output voltage can be trimmed between 20~110% of the rated output voltage High power density 15.6W/inch3 Current sharing up to 2 units Alarm signal output Built-in 12V/0.1A auxiliary output for remote control Built-in remote ON-OFF control Built-in remote sense function 3 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE RSP-3000-12 12V 200A 0 ~ 200A 2400W RSP-3000-24 24V 125A 0 ~ 125A 3000W 150mVp-p 22 ~ 28V 1.0% 0.5% 0.5% RSP-3000-48 48V 62.5A 0 ~ 62.5A 3000W 200mVp-p 43 ~ 56V 1.0% 0.5% 0.5%
RIPPLE & NOISE (max.) Note.2 150mVp-p 10.8 ~ 13.2V VOLTAGE TOLERANCE Note.3 1.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE
Note.5
0.5% 0.5% 1000ms, 80ms at full load 10ms at full load 180 ~ 264VAC 47 ~ 63Hz 0.95/230VAC at full load 86% 20A/180VAC 60A/230VAC <2.0mA / 240VAC 100 ~ 110% rated output power 16A/230VAC 254 ~ 370VDC
89%
90%
Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover 13.8 ~ 16.8V 90 90 5 5 (12V), 110 (12V), 85 28.8 ~ 33.6V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover 5 (24V), 105 5 (48V) (TSW1: detect on heatsink of power transistor) 5 (24V), 75 5 (48V) (TSW2 : detect on heatsink of o/p diode)
OVER TEMPERATURE AUXILIARY POWER(AUX) REMOTE ON/OFF CONTROL FUNCTION ALARM SIGNAL OUTPUT OUTPUT VOLTAGE TRIM CURRENT SHARING WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 12V@0.1A(Only for Remote ON/OFF control) Please see the Function Manual Please see the Function Manual 2.4 ~ 13.2V Please see the Function Manual -20 ~ +70 -40 ~ +85 (Refer to output load derating curve) , 10 ~ 95% RH 20~90% RH non-condensing 0.05%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH 4.8 ~ 28V 9.6 ~ 56V
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
(Note 4)
HARMONIC CURRENT EMS IMMUNITY MTBF
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 104.5K hrs min. MIL-HDBK-217F (25 278*177.8*63.5mm (L*W*H) 4Kg; 4pcs/16Kg/1.89CUFT )
OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The disposition of output load line each must out of bounds to PSU with ten CM.
File Name:RSP-3000-SPEC 2008-12-09
3000W Single Output Power Supply
Mechanical Specification
278 236.3
RSP-3000
Case No.982B
27
12.5
series
Unit:mm
40
38
8-M4(Both Sides) L=5mm 236.3
7.9
27
OUTPUT
4-M4 L=5mm
4
20
+V -V
CN1 CN2 CN3
63.5
LED
SVR
8 642 7 531
8 6 4 2 10 8 6 4 2 7 5 31 97 5 31
Air flow direction
INPUT
10
177.8
162
+
13
16max.
AC Input Terminal Pin No. Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG
Control Pin No. Assignment(CN1,CN2) : HRS DF11-8DP-2DS or equivalent
Pin No. 1 2 3 4 Assignment RCG RC PV PS Pin No. 5,7 6 8 Terminal Assignment Mating Housing -S CS(Current Share) HRS DF11-8DS HRS DF11-**SC or equivalent or equivalent +S -S : -Remote Sensing CS: Load Share +S: +Remote Sensing
RCG: Remote ON/OFF Ground RC : Remote ON/OFF PV :Output Voltage External Control PS : Reference Voltage Terminal
Control Pin No. Assignment(CN3) : HRS DF11-10DP-2DS or equivalent
Pin No. 1 2 3 Assignment P OK GND P OK P OK GND2 Pin No. 4 5 6 Assignment P OK2 RCG RC Pin No. 7 8 9 Assignment AUXG AUX OLP Pin No. 10 Assignment OL-SD Mating Housing Terminal HRS DF11-10DS HRS DF11-**SC or equivalent or equivalent
P OK GND: Power OK Ground P OK: Power OK Signal RCG: Remote ON/OFF Ground
AUXG: Auxiliary Ground RC: Remote ON/OFF AUX: Auxiliary Output
OLP: OLP Signal OL-SD: OLP Shutdown Signal
Block Diagram
I/P EMI FILTER
ACTIVE INRUSH CURRENT LIMITING
PFC fosc : 88KHz PWM fosc : 100KHz
+S
RECTIFIERS & PFC PFC CONTROL O.T.P.
POWER SWITCHING
RECTIFIERS & FILTER
+V -V -S
O.V.P.
O.L.P. PWM CONTROL
LOAD SHARING DETECTION CIRCUIT REMOTE CONTROL FAN P OK RC CS RECTIFIERS & FILTER AUX POWER (12V/0.1A)
AUX POWER
File Name:RSP-3000-SPEC 2008-12-09
TB1
1
2
3
3000W Single Output Power Supply
Derating Curve
RSP-3000
Static Characteristics
Ta=25
series
100
80
100 90
60
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 70 (HORIZONTAL)
50 40
80 70 60
20
-20
180
185
190
195
200
210
220
230
240
250
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
Function Manual
1.Remote ON/OFF (1)Remote ON/OFF control becomes available by applying voltage in CN1 & CN2 & CN3 (2)Table 1.1 shows the specification of Remote ON/OFF function (3)Fig.1.2 shows the example to connect Remote ON/OFF control function Table 1.1 Specification of Remote ON/OFF Connection Method Fig. 1.2(A) Output on SW Open SW Logic Output off SW Close Fig. 1.2(B) SW Open SW Close Fig. 1.2(C) SW Close SW Open
Fig.1.2 Examples of connecting remote ON/OFF
(A)Using external voltage source
(B)Using internal 12V auxiliary output
AUX
AUX 12V RC SW RCG 12V typ.
1K 12V typ.
1K
RC
RCG SW
AUXG AUXG
(C)Using internal 12V auxiliary output
AUX 1K 12V typ.
RC SW RCG AUXG
File Name:RSP-3000-SPEC 2008-12-09
3000W Single Output Power Supply
RSP-3000
series
2.Alarm Signal Output (1)Alarm signal is sent out through "P OK" & "P OK GND" pins (2)An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 10mA (3)Table 2.1 explain the alarm function built-in the power supply Function Description Output of alarm(P OK) The signal is "Low" when the power supply is above Low 80% of the rated output voltage-Power OK (0.5V max at 500mA) P OK High or open The signal turns to be "High" when the power supply (External applied voltage is under 80% of the rated output voltage-Power Fail 500mA max.)
Table 2.1 Explanation of alarm
Output of alarm(P OK2) Low (0.5V max at 10mA) High or open (External applied voltage 10mA max.)
P OK
P OK2
R V 0.1uF
R V
P OK GND
External voltage and R (The max. Sink is 500mA and 30V)
P OK GND2
External voltage and R (The max. Sink is 10mA and 30V)
Fig. 2.2 Internal circuit of P OK (Relay, total is 10W)
Fig. 2.3 Internal circuit of P OK2 (Open collector method)
3.Output Voltage TRIM (1)Adjustment of output voltage is possible between 20~110%(Typ.) of the rated output which is shown in Fig. 3.1 (2)Connecting a resistor externally between PV and-S on CN1 or CN2 that is shown in Fig. 3.2.
Vout
OVP >120%
120 100 100
OUTPUT VOLTAGE (%)
80 60 40 20
OUTPUT CURRENT (%)
V
Non-Linear
80 60 40 20 V
PV 1~6V -S
1
2
3
4
5
6
20
40
60
80
100
120
EXTERNAL VOLTAGE (DC)
OUTPUT VOLTAGE (%)
Fig. 3.1 External voltage (Typ.)
File Name:RSP-3000-SPEC 2008-12-09
3000W Single Output Power Supply
RSP-3000
series
4.Current Sharing (1)Parallel operation is available by connecting the units shown as below (+S,-S and CS are connected mutually in parallel): (2)The voltage difference among each output should be minimized that less than 2% is required (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9 (4) In parallel operation 2 units is the maximum, please consult the manufacture for other applications (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit
No.1(Master)
+V
CN1 +S -S CS
+S -S CS CN2
-V
AC/L AC/N
+S -S
+V -V Load
No.2(Slave)
+V
CN1 +S -S CS
+S -S CS CN2
-V
AC/L AC/N
File Name:RSP-3000-SPEC 2008-12-09


▲Up To Search▲   

 
Price & Availability of RSP-3000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X