![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AC-DC 960 Watts DNR960 Series * * * * * * * xppower.com Rugged Design for Industrial Applications Up to 93% Typical Efficiency Wide Adjustment Range Full Power to 60 C Three Phase Operation Single Phase Operation 70 C Convection Operation. Specification Input Input Voltage * 340-575 VAC 3O (1O operation with 75% output derating), 480-820 VDC Input Frequency * 47-63 Hz Input Current * 1.6 A at 500 VAC Inrush Current * 30 A typical at 500 VAC, cold start Power Factor * 0.7 at 500 VAC input and nominal load Earth Leakage Current * 0.32 mA General Efficiency Isolation * See table * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * 25 KHz typical * DC ON indicator LED Green, DC LOW indicator LED Red DC OK: normally open relay on 24 V models * 370 Khrs to Bellcore, SR-332 issue 6, Model 3 Switching Frequency Signals Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response Ripple & Noise Overvoltage Protection Overload Protection Temperature Coefficient Current Share * * * * * * * * * * * * * * See table See table 1% No minimum load required <150 ms <50 ms 20 ms min at 400 VAC 1% 1% (5% for units in parallel) 4% max deviation recovering to within 1% in 200 s for 50% load change 80 mV pk-pk 20 MHz BW 125-140%, recycle input to reset Continuous current limit 0.02%/C MTBF Environmental Operating Temperature * -25 C to 70 C, derate linearly from 60 C at 3.5%/C (see derating curve) Cooling * Convection-cooled Operating Humidity * 20-95% RH, non-condensing Storage Temperature * -25 C to +85 C Shock * 4 g peak, 22 ms on X, Y and Z axis Vibration * 10 to 500 Hz, 1 g rms on X, Y and Z axis EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions EN55022, class B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, level 4 perf criteria A EN61000-4-3, level 3 perf criteria A EN61000-4-4, level 4 perf criteria A EN61000-4-5, level 3 perf criteria A EN61000-4-6, level 3 perf criteria A EN61000-4-8, level 4 perf criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B * EN60950-1:2001, UL508, UL60950-1 * * * * * * * * * * * 2 units can be paralleled. Total output derates by 10% Safety Approvals AC-DC Models and Ratings Output Voltage 24 V 48 V Notes 1. Reduce by 25% for single phase input operation. DNR960 Output Current(1) 40.0 A 20.0 A Typical Efficiency 92% 91% Model Number DNR960TS24-I DNR960TS48-I Output Voltage Trim 22.5-28.5 V 47.0-56.0 V Mechanical Details 10.86 (275.7) 4.39 (111.3) 0.3 (7.0) 4.96 (125.9) 1 AC Input 4 DC LO DC ON 1 DC Output 10 Voltage Adj. on underside Pin Connections - AC Input Pin Designation 1 Ground 2 L1 3 L2 4 L3 Notes 1. All dimensions in inches (mm). 2. Weight 7.05 lb (3200 g) approx. 3. Screw terminal: 10-24AWG cable size. 4. DC OK Relay 60 VDC at 300 mA Pin 1 2 3 4 5 6 7 8 9 10 Pin Connections - DC Output Designation DC OK* DC OK* +Is -Is +V +V +V -V -V -V * Not available on 48 V versions. Derating Curves DNR960 100 100 80 Load (%) Load (%) DNR48 65 60 40 20 0 -25 Ambient Temp (C) 0 60 70 -25 -20 -10 0 10 Ambien 01-Feb-08 |
Price & Availability of DNR960TS24-I
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |