100W Single Output Switching Power Supply Features : CLG-100 series Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications 3 years warranty (Note.7) F 110 M M SELV EQUIVALENT SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE CURRENT ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & EMC WITHSTAND VOLTAGE ISOLATION RESISTANCE Note.4 LPS CLG-100-20 20V 10 ~ 20V 4.8A 0 ~ 4.8A 96W 150mVp-p ( for 48V only) ( except for 48V ) IP67 CLG-100-36 36V 18 ~ 36V 2.65A 0 ~ 2.65A 95.4W 150mVp-p CLG-100-48 48V 24 ~ 48V 2A 0 ~ 2A 96W 200mVp-p CLG-100-12 12V Note.6 5A Note.6 0 ~ 5A Note.6 60W CLG-100-15 15V 7.5 ~ 15V 5A 0 ~ 5A 75W 150mVp-p CLG-100-24 24V 12 ~ 24V 4A 0 ~ 4A 96W 150mVp-p CLG-100-27 27V 13.5 ~ 27V 3.55A 0 ~ 3.55A 95.85W 150mVp-p CONSTANT CURRENT REGION Note.8 6 ~ 12V RIPPLE & NOISE (max.) Note.2 150mVp-p Fixed. Can be modified between 0% ~ -15% rated output voltage Fixed. Can be modified between 3% ~ -25% rated output current 3.0% 1.0% 2.0% 1200ms, 80ms / 230VAC 60ms / 230VAC Note.5 90 ~ 264VAC 3.0% 3.0% 3.0% 3.0% 2.0% 2.0% 1200ms, 80ms / 115VAC at full load 30ms / 115VAC at full load 127 ~ 370VDC PF>0.95/115VAC at full load 85% 87% 87% 87% 0.45A/230VAC 87% 20V ~ 48V:1.1A/115VAC 87% 0.55A/230VAC 15V:0.9A/115VAC 47 ~ 63Hz PF>0.95/230VAC 83% 12V:0.8A/115VAC 0.4A/230VAC COLD START 40A/230VAC 0.5mA / 240VAC 95 ~ 100% Protection type : Constant current limiting, recovers automatically after fault condition is removed Note.4 Hiccup mode, recovers automatically after fault condition is removed 13 ~ 16V 90 10 16.5 ~ 20V (RTH2) 22 ~ 27V 27 ~ 34V 29 ~ 36V 39 ~ 48V 52 ~ 64V Protection type : Shut down and latch off o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 -40 ~ +80 0.03%/ (Refer to output load derating curve) , 10 ~ 95% RH (0 ~ 50 ) 20 ~ 90% RH non-condensing 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13 CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:1.5KVAC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3 HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A 301Khrs min. MIL-HDBK-217F (25 222*68*39mm (L*W*H) 1.0Kg; 12pcs/13Kg/0.49CUFT ) OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 . 8. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. File Name:CLG-100-SPEC 2008-12-10 100W Single Output Switching Power Supply Mechanical Specification CLG-100 Case No. 954A series Unit:mm 222.2 12 9.6 300 20 198.2 9.4 AC/L(Brown) AC/N(Blue) FG (Greed/Yellow) 300 20 34.2 18AWG 3C 18AWG 2C +V(Red) -V(Black) 9.4 68 4.2 4PL Block Diagram Fosc : 100KHz EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER O.L.P. FG PFC CONTROL DETECTION CIRCUIT O.V.P. +V -V I/P O.L.P. PWM & PFC CONTROL Derating Curve Static Characteristics fosc : 100KHz 100 100 90 80 80 70 60 LOAD (%) 40 LOAD (%) 60 50 40 20 -30 -25 -5 0 15 30 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:CLG-100-SPEC 2008-12-10 38.75 |
Price & Availability of CLG-100 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |