If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
60W Single Output Medical Type Features : 4"x2" miniature size Universal AC input/Full range Low leakage current<200uA RPS-60 series Protections: Short circuit / Overload / Over voltage Cooling by free air convection UL60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved No load power consumption<0.75W Fixed switch frequency at 100KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK LOAD(10sec.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE RPS-60-3.3 3.3V 10A 0 ~ 11A 33W Note.4 36.3W RPS-60-5 5V 10A 0 ~ 11A 50W 55W 80mVp-p 4.75 ~ 5.5V 2.0% 0.5% 1.0% RPS-60-12 12V 5A 0 ~ 5.5A 60W 66W 120mVp-p 11.4 ~ 13.2V 2.0% 0.5% 1.0% RPS-60-15 15V 4A 0 ~ 4.4A 60W 66W 150mVp-p 13.5 ~ 16.5V 2.0% 0.5% 1.0% RPS-60-24 24V 2.5A 0 ~ 2.75A 60W 66W 240mVp-p 22.8 ~ 27.6V 1.0% 0.5% 1.0% RPS-60-48 48V 1.25A 0 ~ 1.375A 60W 66W 300mVp-p 45.6 ~ 52.8V 1.0% 0.5% 1.0% RIPPLE & NOISE (max.) Note.2 80mVp-p 3.1 ~ 3.6V 2.0% 0.5% 1.0% 500ms, 30ms/230VAC 50ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 74% 1.8A/115VAC 79% 500ms, 30ms/115VAC at full load 13ms/115VAC at full load 127 ~ 370VDC 83% 30A/115VAC 84% 85% 86% 1 A/230VAC COLD START 60A/230VAC For earth <200uA / 264VAC, For patient <100uA/264VAC 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 5V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved 28.4 ~ 32.4V 55.2 ~ 64.8V I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B (Note 5) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A 353.6Khrs min. MIL-HDBK-217F (25 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:RPS-60-SPEC 2008-03-25 60W Single Output Medical Type Mechanical Specification 101.6 95.25 RPS-60 series Unit:mm 3.175 3.175 SVR1 50.8 44.45 CN1 3 2 1 1 2 3 4 CN2 4- 3.3 3 max. 29 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B4P-VH or equivalent Pin No. 1,2 3,4 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Block Diagram RECTIFIERS & FILTER RECTIFIERS & FILTER fosc : 100KHz POWER SWITCHING I/P EMI FILTER +V -V FG O.L.P. CONTROL DETECTION CIRCUIT O.V.P. Output Derating Output Derating VS Input Voltage Ta=25 100 100 90 80 80 60 70 LOAD (%) LOAD (%) 0 10 20 30 40 50 60 65 70 (HORIZONTAL) 40 60 50 40 20 -20 90 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RPS-60-SPEC 2008-03-25 |
Price & Availability of RPS-60
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |