Datasheet File OCR Text: |
Embedded Power for Business-Critical Continuity LPT40-M Series 40 Watts Total Power: Input Voltage: # of Outputs: 40-55Watts 85-264VAC 120-300VDC Triple Rev. 2.16.09_165 LPT40-M Series 1 of 3 Special Features * * * * * * * * * * * Universalinput 3"x5"footprint Lessthan1Uhigh Remotesenseonmainoutput Built-inEMIfilter Lowoutputripple Adjustable5Voutput Overvoltageprotection Overloadprotection 110KHzswitchingfrequency LPX40enclosurekitavailable Electrical Specifications Input Inputrange: Frequency: Inrushcurrent: Inputcurrent: Efficiency: EMI: 8 5-264VAC 120-300VDC 47-440Hz < 18Apeak@115VAC; <36Apeak@230VAC,coldstart@25C 1Amax.(RMS)@115VAC 70%typicalatfullload(60%forLPT41) F CCClassAconducted;CISPR22ClassAconducted EN55022ClassAconducted; VDE0878PT3ClassAconducted <75A@50/60Hz,264VACinput Safetyground leakagecurrent: Output MaximumPower: 40Wforconvection;55Wwith30CFMforcedair 2%onoutput1;5%onoutputs2,3 -5,+10%minimum 20ms@40Wload,115VACnominalline S hortcircuitprotectiononalloutputs.Caseoverloadprotected @110%to145%abovepeakrating 5.7to6.7VDConthemainoutput LPT41:3.6to4.6VDC Compensatesfor0.5Vleaddropmin.Willoperatewithoutremote senseconnected.Reverseconnectionprotected. Crossregulation: Adjustmentrange: Hold-uptime: Overloadprotection: Overvoltageprotection: Remotesense: Safety * * * * VDE UL CSA CE 0750/EN60601-1(IEC601) 113769 UL2601 E182560 CSA22.2No.601.1 LR109492 Mark(LVD) Embedded Power for Business-Critical Continuity Rev. 2.16.09_165 LPT40-M Series 2 of 3 EnvironmentalSpecifications Operatingtemperature: Electromagnetic susceptibility: Humidity: Vibration: Storagetemperature: Temperaturecoefficient: MTBFdemonstrated: 0to50Cambientderateeachoutputat2.5%perdegreefrom50to70C,-20Cstartup. DesignedtomeetIEC801,-2,-3,-4,-5,-6,Level3 Operating;non-condensing5%to95% Threeorthogonalaxes,sweepat1oct/min,5min.dwellatfourmajorresonances0.75Gpeak5Hzto500 Hz,operational -40to85C .04%perC >550,000hoursatfullloadand25Cambientconditions OrderingInformation Output Minimum Maximum Load with Maximum Load with Peak Ripple P/P Regulation2 Voltage Load Convection cooling 30CFM Forced Air Load1 (PARD)3 +5V 0.4A 4A 5A 7A 2% 50mV LPT42-M +12V 0.2A 2A 2.5A 4A 5% 120mV -12V 0A 0.5A 0.7A 1A 5% 120mV +5V 0.4A 4A 5A 7A 2% 50mV LPT45-M +15V 0.2A 2A 2.5A 3A 5% 150mV -15V 0A 0.5A 0.7A 1A 5% 150mV 1.Peakcurrentlasting<30secondswithamaximum10%dutycycle. 2.At25Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings. 3.Peak-to-peakwith20MHzbandwidthand10Finparallelwitha0.1Fcapacitoratratedlinevoltageandloadranges. 4.MinimumLoadsarerequired. Model Number Power Derating Curve 55W 30 CFM Forced Air Cooling 40W 30W Output Power (Watts) 20W Natural Convection Cooling 27.5W 20W 10W 0W 0C 10C 20C 30C 40C 50C 60C 70C TA - Ambient Temperature - C Embedded Power for Business-Critical Continuity MechanicalDrawing 5.00" (127) Americas 5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile: +17609300698 Rev. 2.16.09_165 LPT40-M Series 3 of 3 0.22" (5.6) M1 GND 4.55" (115.6) SK201 _+ 1 2 3 4 5 6 M2 3.00" (76.2) 2.55" (64.8) 3 1 Remote Sense Connector Voltage Adj. Pot Europe (UK) SK 2 WaterfrontBusinessPark MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile: +44(0)1384843355 SK 1 Asia (HK) N L 0.15" (4) DIA (4 places) 1.14" (29) 14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile: +85221763888 Forglobalcontact,visit: www.PowerConversion.com techsupport.embeddedpower @emerson.com 0.12" (3) Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis informationorforanyerrorsoromissions. PinAssignments Connector SK1-1 SK1-3 SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 LPT42-M Line Neutral +12V +5V +5V Common -12V +Sense -Sense LPT45-M Line Neutral +15V +5V +5V Common -15V +Sense -Sense MatingConnectors ACInput: Molex09-50-8031(USA) 09-91-0300(UK) PINS:08-58-0111 DC Molex09-50-8061(USA) Outputs: 09-91-0600(UK) PINS:08-58-0111 Remote Molex22-01-2025 Sense: PINS:08-52-0114 EmersonNetworkPowerConnectorKit#70-841-006, includesalloftheabove 1. Specificationssubjecttochangewithoutnotice. 2 . Alldimensionsininches(mm),toleranceis0.02" (0.5mm) 3. MountingholesM1andM2shouldbegroundedfor EMIpurposes. 4. MountingholeM1issafetygroundconnection. 5. Specificationsareforconvectionratingatfactorysettingsat115VACinput,25Cunlessotherwisestated. 6. Warranty:2year 7. Weight:0.5lbs/0.23kg Emerson Network Power. Thegloballeaderinenabling business-criticalcontinuity. ACPower Connectivity DCPower EmbeddedComputing Embedded Power Monitoring OutsidePlant PowerSwitching&Controls PrecisionCooling Racks&IntegratedCabinets Services SurgeProtection EmersonNetworkPower.com EmersonNetworkPowerandtheEmerson NetworkPowerlogoaretrademarksand servicemarksofEmersonElectricCo. (c)2008EmersonElectricCo. Common Common |
Price & Availability of LPT42-M |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |