TDF8599 I2C-bus controlled dual channel 43 W/2 single channel 85 W/1 class-D power amplifier with load diagnostics Rev. 01 -- 13 November 2008 Product data sheet 1. General description The TDF8599 is a dual Bridge-Tied Load (BTL) car audio amplifier comprising an NDMOST-NDMOST output stage based on SOI BCDMOS technology. Low dissipation enables the TDF8599 high-efficiency, class-D amplifier to be used with a smaller heat sink than those normally used with standard class-AB amplifiers. The TDF8599 can operate in either non-I2C-bus mode or I2C-bus mode. When in I2C-bus mode, DC load detection results and fault conditions can be easily read back from the device. Up to five I2C-bus addresses can be selected when an external resistor is connected to pin ADS. When pin ADS is short circuited to ground, the TDF8599 operates in non-I2C-bus mode. Switching between Operating mode and Mute mode in non-I2C-bus mode is only possible using pins EN and SEL_MUTE. 2. Features I I I I I I I I I I I I I I I High-efficiency Low quiescent current Operating voltage from 8 V to 18 V Two 4 /2 capable BTL channels or one 1 capable BTL channel Differential inputs Supports I2C-bus mode with five I2C-bus addresses or non-I2C-bus mode operation Clip detect Independent short circuit protection for each channel Advanced short circuit protection for load, GND and supply Load dump protection Thermal foldback and thermal protection DC offset protection Selectable AD or BD modulation Parallel channel mode for high current drive capability Advanced clocking: N Switchable oscillator clock source: internal (master) or external (slave) N Spread spectrum mode N Phase staggering N Frequency hopping I No `pop noise' caused by DC output offset voltage NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics I I2C-bus mode: N DC load detection N AC load detection N Thermal pre-warning diagnostic level setting N Identification of activated protections or warnings N Selectable diagnostic information available using pin DIAG I Qualified in accordance with AEC-Q100 3. Applications I Car audio applications 4. Quick reference data Table 1. Symbol VP Istb Iq(tot) Quick reference data Parameter supply voltage standby current total quiescent current voltage on pin EN < 0.8 V Operating mode; no load, snubbers and filter connected Stereo mode; THD = 1 %; RL = 4 THD = 10 %; RL = 4 square wave (EIAJ); RL = 4 THD = 1 %; RL = 2 THD = 10 %; RL = 2 square wave (EIAJ); RL = 2 Parallel mode THD = 10 %; RL = 1 [1] Output power is measured indirectly based on RDSon measurement. [1] [1] Conditions Min 8 - Typ 14.4 90 Max 18 10 120 Unit V A mA General; Vp = 14.4 V Dual BTL channel; Vp = 14.4 V Po output power 18 24 29 39 20 26 40 32 43 70 85 W W W W W W W 5. Ordering information Table 2. Ordering information Package Name TDF8599TH TDF8599TD HSOP36 HSOP36 Description plastic, heatsink small outline package; 36 leads; low stand-off height plastic, heatsink small outline package; 36 leads; low stand-off height Version SOT851-2 SOT938-1 Type number TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 2 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 6. Block diagram VDDA 10 9 8 DRIVER HIGH PWM CTRL IN1P 1 DRIVER LOW PGND1 VP1 IN1N 2 PWM CTRL DRIVER LOW ACGND 5 + VP1 31 VP2 24 AGND SVRR STABI1 34 32 VP1 VSTAB1 BOOT1N TDF8599 33 OUT1N 29 BOOT1P DRIVER HIGH 28 OUT1P PGND1 VP2 DRIVER HIGH PWM CTRL 23 BOOT2N 22 DRIVER LOW PGND2 VP2 26 OUT2N IN2P 3 BOOT2P IN2N 4 PWM CTRL DRIVER HIGH 27 DRIVER LOW OUT2P OSCSET OSCIO SSM MOD VDDD EN SEL_MUTE SCL SDA ADS 18 19 17 12 35 6 7 16 15 11 36 GNDD/HW 14 DIAG 13 20 30 PGND1 MODE SELECT + I2C-BUS DIAGNOSTICS OSCILLATOR PGND2 5 V STABI STABI2 21 VSTAB2 PROTECTIONS OVP, OCP, OTP UVP, TF, WP,DCP 25 PGND2 001aai766 CLIP DCP Fig 1. Block diagram TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 3 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 7. Pinning information 7.1 Pinning GNDD/HW 36 VDDD 35 VSTAB1 34 OUT1N 33 BOOT1N 32 VP1 31 PGND1 30 BOOT1P 29 OUT1P 28 OUT2P 27 BOOT2P 26 PGND2 25 VP2 24 BOOT2N 23 OUT2N 22 VSTAB2 21 DCP 20 OSCIO 19 001aai767 1 2 3 4 5 6 7 8 IN1P IN1N IN2P IN2N ACGND EN SEL_MUTE SVRR AGND TDF8599TH 9 10 VDDA 11 ADS 12 MOD 13 CLIP 14 DIAG 15 SDA 16 SCL 17 SSM 18 OSCSET Fig 2. Heatsink up (top view) pin configuration TDF8599TH TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 4 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics IN1P IN1N IN2P IN2N ACGND EN SEL_MUTE SVRR AGND 1 2 3 4 5 6 7 8 9 36 GNDD/HW 35 VDDD 34 VSTAB1 33 OUT1N 32 BOOT1N 31 VP1 30 PGND1 29 BOOT1P TDF8599TD 28 OUT1P 27 OUT2P 26 BOOT2P 25 PGND2 24 VP2 23 BOOT2N 22 OUT2N 21 VSTAB2 20 DCP 19 OSCIO VDDA 10 ADS 11 MOD 12 CLIP 13 DIAG 14 SDA 15 SCL 16 SSM 17 OSCSET 18 001aai768 Fig 3. Heatsink down (top view) pin configuration TDF8599TD 7.2 Pin description Table 3. Symbol IN1P IN1N IN2P IN2N ACGND EN Pin description Pin 1 2 3 4 5 6 Type[1] I I I I I I Description channel 1 positive audio input channel 1 negative audio input channel 2 positive audio input channel 2 negative audio input decoupling for input reference voltage enable input: non-I2C-bus mode: switch between off and Mute mode I2C-bus mode: off and Standby mode SEL_MUTE SVRR AGND VDDA ADS MOD TDF8599_1 7 8 9 10 11 12 I I G P I I select mute or on (unmute) decoupling for internal half supply reference voltage analog supply ground analog supply voltage non-I2C-bus mode: connected to ground I2C-bus mode: selection and address selection pin modulation mode, phase shift and parallel mode select (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 5 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics Pin description ...continued Pin 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 G O G P O O P G O I/O I Type[1] O O I/O I Description clip output; open-drain diagnostic output; open-drain I2C-bus data input and output I2C-bus clock input master setting: Spread spectrum mode frequency slave setting: phase lock operation master/slave setting oscillator master only setting: set internal oscillator frequency external oscillator slave setting: input internal oscillator master setting: output DC protection input for the filtered output voltages decoupling internal stabilizer 2 for DMOST drivers channel 2 negative PWM output boot 2 negative bootstrap capacitor channel 2 power supply voltage channel 2 power ground boot 2 positive bootstrap capacitor channel 2 positive PWM output channel 1 positive PWM output boot 1 positive bootstrap capacitor channel 1 power ground channel 1 power supply voltage boot 1 negative bootstrap capacitor channel 1 negative PWM output decoupling internal stabilizer 1 for DMOST drivers decoupling of the internal 5 V logic supply ground digital supply voltage handle wafer connection Table 3. Symbol CLIP DIAG SDA SCL SSM OSCSET OSCIO DCP VSTAB2 OUT2N BOOT2N VP2 PGND2 BOOT2P OUT2P OUT1P BOOT1P PGND1 VP1 BOOT1N OUT1N VSTAB1 VDDD GNDD/HW [1] I = input, O = output, I/O = input/output, G = ground and P = power supply. 8. Functional description 8.1 General The TDF8599 is a dual full bridge (BTL) audio power amplifier utilizing class-D technology. The audio input signal is converted into a Pulse-Width Modulated (PWM) signal using the analog input and PWM control stages. A PWM signal is applied to driver circuits for both high-side and low-side enabling the DMOS power output transistors to be driven. An external 2nd order low-pass filter converts the PWM signal into an analog audio signal across the loudspeakers. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 6 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics The TDF8599 includes integrated common circuits for all channels such as the oscillator, all reference sources, mode functionality and a digital timing manager. In addition, the built-in protection includes thermal foldback, temperature, overcurrent and overvoltage (load dump). The TDF8599 operates in either I2C-bus mode or non-I2C-bus mode. In I2C-bus mode, DC load detection, frequency hopping and extended configurability are provided together with enhanced diagnostic information. 8.2 Mode selection The mode pins EN and SEL_MUTE enable mute state, I2C-bus mode and Operating mode switching. Pin SEL_MUTE is used to mute and demute the device and must be connected to an external capacitor. This capacitor generates a time constant which is used to ensure smooth fade-in and fade-out of the input signal. When pin EN is LOW, the TDF8599 is off and the supply current is at its lowest value (typically 2 A). When off, the TDF8599 is completely deactivated and will not react to I2C-bus commands. The TDF8599 is enabled when pin EN is HIGH. A resistor connected between pin ADS and ground determines if the TDF8599 is in I2C-bus mode or in non-I2C-bus mode (see Section 9). I2C-bus mode is selected by leaving the connection between pin ADS and pin GND open. In I2C-bus mode with pin EN HIGH, the TDF8599 is in Standby mode and will wait for further commands. Non-I2C-bus mode is selected by connecting pin ADS to pin GND. In non-I2C-bus mode, the default TDF8599 state is Mute mode. The amplifiers switch idle (50 % duty cycle) and the audio signal is suppressed at the output. In addition, the capacitor (CSVRR) is charged to half the supply voltage. To enter Operating mode, pin SEL_MUTE must be released (see Figure 4) and capacitor (CON) charged by an internal pull-up. S2 3.3 V EN S2 3.3 V EN TDF8599 SEL_MUTE SEL_MUTE TDF8599 CON S1 CON 001aai769 001aai770 a. non-I2C-bus mode Fig 4. Mode selection b. I2C-bus mode I2C-bus mode and non-I2C-bus mode control are described in Table 4 and Table 5. Switches S1 and S2 are illustrated in Figure 4. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 7 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics I2C-bus mode operation Bit IB1[D0] 1 1 0 Bit IB2[D0] 0 1 X[1] X[1] Mode Operating mode Mute mode Standby mode off Table 4. Pin EN S2 closed S2 open [1] X = do not care X[1] Table 5. Pin EN S2 closed S2 open Non-I2C-bus mode operation Bit IB2[D0] S1 open S2 closed do not care Mode Operating mode Mute mode off 8.3 Pulse-width modulation frequency The output signal from the amplifier is a PWM signal with a switching frequency of fosc. This frequency is set by connecting a resistor (Rosc) between pins OSCSET and AGND. The optimal clock frequency setting is between 300 kHz and 400 kHz. Connecting a resistor with a value of 39 k, for example, sets the clock frequency to 320 kHz. The external capacitor (Cosc) has no influence on the oscillator frequency. It does however, reduce jitter and sensitivity to disturbance. Using a 2nd order LC demodulation filter in the application generates an analog audio signal across the loudspeaker. 8.3.1 Master and slave mode selection In a master and slave configuration, multiple TDF8599 devices are daisy-chained together in one audio application with a single device providing the clock frequency signal for the other devices. In this situation, it is recommended that the oscillators of all devices are synchronized for optimum EMI behavior as follows: All OSCIO pins are connected together and one TDF8599 in the application is configured as the clock-master. All other TDF8599 devices are configured as clock-slaves (see Figure 6). * The clock-master pin OSCIO is configured as the oscillator output. When a resistor (Rosc) is connected between pins OSCSET and AGND, the TDF8599 is in Master mode. * The clock-slave pins OSCIO are configured as the oscillator inputs. When pin OSCSET is directly connected to pin AGND (see Table 6), the TDF8599 is in Slave mode. Table 6. Mode Master Slave Mode setting OSCIO Settings Pin OSCSET Rosc > 26 k Rosc = 0 k; shorted to AGND Pin OSCIO output input TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 8 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics The value of the resistor Rosc sets the carrier frequency based on the following formula: 12.45 x 10 f osc = --------------------------- [ Hz ] R osc 9 (1) 50 Rosc (k) 40 001aai771 30 20 10 0 300 350 400 450 500 fosc (kHz) Fig 5. Oscillator frequency as function of Rosc OSCSET OSCSET Rosc Cosc OSCSET TDF8599 OSCIO Master TDF8599 OSCIO TDF8599 OSCIO Slave 2 001aai772 fosc R Slave 1 Fig 6. Master and slave configuration In Master mode, Spread spectrum mode and frequency hopping can be enabled. In Slave mode, phase staggering and phase lock operation can be selected. An external clock can be used as the master-clock on pin OSCIO of the slave devices. When using an external clock it must remain active during the shutdown sequence to ensure that all devices are switched off and able to enter the off state as described in Section 8.2. 8.3.2 Spread spectrum mode (Master mode) Spread spectrum mode is a technique of modulating the oscillator frequency with a slow varying signal to broaden the switching spectrum, thereby reducing the spectral density of the EMI. Connecting a capacitor (CSSM) to pin SSM enables Spread spectrum mode (see Figure 7). When pin SSM is connected to pin AGND, Spread spectrum mode is disabled. The capacitor on pin SSM (CSSM) sets the spreading frequency when Spread spectrum mode is active. The current (ISSM) flowing in and out of pin SSM is typically 5 A. This gives a triangular voltage on pin SSM that sweeps around the voltage set by pin OSCSET 5 %. The voltage on pin SSM is used to modulate the oscillator frequency. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 9 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics The spread spectrum frequency can be calculated using: I SSM f SSM = ----------------------------------------------------- [ Hz ] 2 x C SSM x V 1 x 10 % where the voltage on pin OSCSET = V1 and is calculated as 100 A x Rosc (V) with ISSM = 5 A. (2) 100 A 100 A OSCSET Rosc Cosc 5 A ISSM OSCSET Rosc Cosc SSM SSM CSSM 001aai773 001aai774 a. Off Fig 7. Spread spectrum mode b. On The frequency swings between 0.95 x fosc and 1.05 x fosc, see Figure 8. OSCIO max(V) SSM min(V) t (ms) 001aai775 Fig 8. Spread spectrum operation in Master mode 8.3.3 Frequency hopping (Master mode) Frequency hopping is a technique used to change the oscillator frequency for AM tuner compatibility. In Master mode, the resistor connected between pin OSCSET and pin AGND sets the oscillator frequency. In I2C-bus mode, this frequency can be varied by 10 % to 0.9 x fosc or 1.1 x fosc using bit IB1[D3:D4]. See Figure 8. 8.3.4 Phase lock operation (Slave mode) In Slave mode, phase lock operation can be used to reduce the jitter effects of the external oscillator signal connected to pin OSCIO. Phase lock operation is also needed to enable phase staggering, see Section 8.4.2. Phase lock operation is enabled when the oscillator is in Slave mode by connecting two capacitors (CPLL_S and CPLL_p) and a resistor (RPLL) between pin SSM and pin AGND (see Figure 9). Connecting pin SSM to pin AGND disables phase lock operation and causes the slave to use the external oscillator signal TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 10 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics directly. Values for CPLL_s, CPLL_p and RPLL depend on the desired loop bandwidth (BWPLL) of the PLL. RPLL is given by: RPLL = 8.4 x BWPLL . The corresponding values for CPLL_s and CPLL_p are given by: 0.032 C PLL_p = ------------------------------------ [ F ] R PLL x BW PLL (3) Remark: CPLL_P is only needed when /4 phase shift is selected. See Section 8.4.2 for more detailed information. 0.8 C PLL_s = ------------------------------------ [ F ] R PLL x BW PLL (4) When pin OSCIO is connected to a clock-master with Spread spectrum mode enabled, the PLL loop bandwidth BWPLL should be 100 x fSSM. 100 A OSCSET 100 A OSCSET SSM CPLL_s PLL SSM PLL RPLL CPLL_P(1) 001aai776 001aai777 a. Off Fig 9. Phase lock operation b. On See Table 7 for all oscillator modes. Table 7. Oscillator modes OSCIO pin output output input input SSM pin Cssm shorted to AGND CPLL + RPLL shorted to AGND Oscillator modes master, spread spectrum master, no spread spectrum slave, PLL enabled slave, PLL disabled OSCSET pin Rosc > 26 k Rosc > 26 k Rosc = 0 Rosc = 0 8.4 Operation mode selection Pin MOD is used to select specific operation modes. The resistor (RMOD) connected between pins MOD and AGND determines the operation mode. The mode of operation depends on whether non-I2C-bus mode or I2C-bus mode is active. This is in turn determined by the resistor value connected between pins ADS and AGND. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 11 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics In non-I2C-bus mode pin MOD is used to select: 1. AD or BD modulation type (see Section 8.4.1). 2. 12 phase shift when oscillator is used in Slave mode (see Section 8.4.2). 3. Parallel mode operation (see Section 8.4.3). In I2C-bus mode, pin MOD can only select Parallel mode. In addition, the modulation type and phase shift are programmed using I2C-bus commands. Table 8. RMOD (k) 4.7 13 33 100 (open) Parallel mode Operation mode selection with the MOD pin I2C-bus mode Non-I2C-bus mode AD modulation: no phase shift in Slave mode BD modulation: no phase shift in Slave mode AD modulation: 12 phase shift in Slave mode BD modulation: 12 phase shift in Slave mode AD modulation: no phase shift in Slave mode BD modulation: no phase shift in Slave mode 0 (short to GND) Stereo mode The information on pin MOD is latched when one of the TDF8599 outputs starts switching to avoid incorrect information on pin MOD caused by disturbances of switching amplifier outputs. 8.4.1 Modulation mode In non-I2C-bus mode, pin MOD is used to select either AD or BD modulation mode. In I2C-bus mode, the modulation mode is selected using an I2C-bus command. * AD modulation mode: the bridge halves switch in opposite phase. * BD modulation mode: the bridge halves switch in phase but the input signal for the modulators is inverted. Figure 10, Figure 11 and Figure 12 show simplified representations of AD and BD modulation. +VP INxP +VP INxN OUTP OUTN AD BD 001aai778 Fig 10. AD/BD modulation switching circuit TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 12 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics INxP OUTxP 001aai779 a. Bridge half 1. INxN OUTxN 001aai780 b. Bridge half 2 switched in the opposite phase to bridge half 1. Fig 11. AD modulation INxP OUTxP OUTxP, OUTxN 001aai781 a. Phase switching cycle. INxN OUTxN 001aai782 b. Inverted signal to the modulator. Fig 12. BD modulation 8.4.2 Phase staggering (Slave mode) In Slave mode with phase lock operation enabled, a phase shift with respect to the incoming clock signal can be selected to distribute the switching moments over time. In non-I2C-bus mode, 12 phase shift can be programmed using pin MOD. In I2C-bus mode, five different phase shifts (14 , 13 , 12 , 23 , 34 ) can be selected using the I2C-bus bits (IB3[D1:D3]). See Figure 9 for selection of the phase shift in non-I2C-bus mode with pin MOD. An additional capacitor must be connected to pin SSM when 14 phase shift is used (see Figure 9). An example of using 12 phase shift for BD modulation is shown in Figure 13. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 13 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics OUT1P phase 0 OUT1N master OUT2P OUT2N OUT1P 1/2 OUT1N slave OUT2P 3/2 001aai783 OUT2N Fig 13. Master and slave operation with 12 phase shift. 8.4.3 Parallel mode In Parallel mode; the two output stages operate in parallel to enlarge the drive capability. The inputs and outputs for Parallel mode must be connected on the Printed-Circuit Board (PCB) as shown in Figure 14. The parallel connection can be made after the output filter, as shown in Figure 14 or directly to the device output pins. + - IN1P OUT1N - IN1N OUT1P IN2N TDF8599 OUT2P + IN2P MOD RMOD OUT2N 001aai784 Fig 14. Mono and Parallel modes In Parallel mode, the channel 1 I2C-bus bits can be programmed using the I2C-bus. However, clip detection must be deactivated by disabling clip detection for both channel 1 and channel 2. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 14 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 8.5 Protection The TDF8599 includes a range of built-in protection functions. How the TDF8599 handles the various possible fault conditions differs for each protection and is described in the following sections: Table 9. Overview of protection types Reference Section 8.5.1 Section 8.5.2 Section 8.5.3 Section 8.5.4 Section 8.5.5 Section 8.5.6 Section 8.5.6 Protection type Thermal foldback Overtemperature Overcurrent Window DC Offset Undervoltage Overvoltage 8.5.1 Thermal foldback Thermal Foldback Protection (TFP) is activated when the junction temperature exceeds the threshold level (145 C). TFP decreases amplifier gain such that the combination of dissipation and Rth(j-a) create a junction temperature around the threshold level. The device will not completely switch off but remains operational at the lower output power levels. If the junction temperature continues to increase, a second built-in temperature protection threshold level shuts down the amplifier completely. 8.5.2 Overtemperature protection If the junction temperature Tj > 160 C, the OverTemperature Protection (OTP) is activated and the power stage immediately shuts down. 8.5.3 Overcurrent protection OverCurrent Protection (OCP) is activated when the output current exceeds the maximum output current of 8 A. OCP regulates the output voltage such that the maximum output current is limited to 8 A. The amplifier outputs keep switching and the amplifier is NOT shutdown completely. This is called current limiting. OCP also detects when the loudspeaker terminals are short circuited or one of the amplifier's demodulated outputs is short circuited to one of the supply lines. In either case, the shorted channel(s) are switched off. The amplifier can distinguish between loudspeaker impedance drops and a low-ohmic short across the load or one of the supply lines. This impedance threshold depends on the supply voltage used. When a short is made across the load causing the impedance to drop below the threshold level, the shorted channel(s) are switched off. They try to restart every 50 ms. If the short circuit condition is still present after 50 ms, the cycle repeats. The average dissipation will be low because of this forced reduced duty cycle. When a channel is switched off due to a short circuit on one of the supply lines, Window Protection (WP) is activated. WP ensures the amplifier does not start-up after 50 ms until the supply line short circuit is removed. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 15 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 8.5.4 Window protection Window Protection (WP) checks the PWM output voltage before switching from Standby mode to Mute mode (outputs switching) and is activated as follows: * During the start-up sequence: - When the TDF8599 is switched from standby to mute (td(stb-mute)). When a short circuit on one of the output terminals (i.e. between VP and GND) is detected, the start-up procedure is interrupted and the TDF8599 waits for open circuit outputs. No large currents flow in the event of a short circuit to the supply lines because the check is performed before the power stages are enabled. * During operation: - A short to one of the supply lines activates OCP causing the amplifier channel to shutdown. After 50 ms the amplifier channel restarts and WP is activated. However, the corresponding amplifier channel will not start-up until the supply line short circuit has been removed. 8.5.5 DC Protection DC Protection (DCP) is activated when the DC content in the demodulated output voltage exceeds a set threshold (typically 2 V). DCP is active in both Mute mode and Operating mode. False triggering of the DCP by low frequencies in the audio signal is prevented using the external capacitor (CF) to generate a cut-off frequency as shown in Figure 15. OUT1P OUT1N OUT2P OUT2N V to I IB1[D6] V to I IB2[D6] Vref 50 k DCP CF DIAG IB1[D7] DB1[D7] S4 IB2[D7] S3 S Q switch off channels 001aai785 Fig 15. DC offset protection and diagnostic output TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 16 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics In I2C-bus mode, DC offsets generate a voltage shift around the bias voltage. When the voltage shift exceeds threshold values, the offset alarm bit DB1[D2] is set and if bit IB1[D7] is set, diagnostic information is also given. Any detected offset shuts down both channels when bit IB2[D7] is not set. To restart the TDF8599 in I2C-bus mode, pin EN must be toggled or DCP disabled by connecting pin DCP to pin GND. In non-I2C-bus mode, when an offset is detected, DCP always gives diagnostic information on pin DIAG and shuts down both channels. Connecting pin DCP to pin GND disables DCP. 8.5.6 Supply voltages UnderVoltage Protection (UVP) is activated when the supply voltage drops below the UVP threshold (typically 7.5 V). UVP triggers the UVP circuit causing the system to first mute and then stop switching. When the supply voltage rises above the threshold level, the system restarts. OverVoltage Protection (OVP) is activated when the supply voltage exceeds the OVP threshold (typically 27 V). The OVP (or load dump) circuit is activated and the power stages are shutdown. An overview of all protection circuits and the amplifier states is given in Table 10. 8.5.7 Overview of protection circuits and amplifier states Table 10. Overview of TDF8599 protection circuits and amplifier states Amplifier state Complete shutdown TFP OTP OCP WP DCP UVP OVP [1] [2] [3] [4] [5] [6] When fault is removed. Amplifier gain depends on the junction temperature and size of the heat sink. TFP influences restart timing depending on heat sink size. Shorted load causes a restart of the channel every 50 ms. Latched protection is reset by toggling the pin EN or by disabling DCP in I2C-bus mode. In I2C-bus mode deep supply voltage drops will cause a Power-On Reset (POR). The restart requires an I2C-bus command. Protection circuit name Channel shutdown N[2] N Y Y N N N Restart[1] Y[3] Y[3] Y[4] Y N[5] Y[6] Y N[2] Y N N Y Y Y TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 17 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 8.6 Diagnostic output 8.6.1 Diagnostic table The diagnostic information for I2C-bus mode and non-I2C-bus mode is shown in Table 11. The instruction bitmap and data bytes are described in Table 14 and Table 15. Pins DIAG and CLIP have an open-drain output which must have an external pull-up resistor connected to an external voltage. Pins CLIP and DIAG can show both fixed and I2C-bus selectable information. Pin DIAG goes LOW when a short circuit to one of the amplifier outputs occurs. The microprocessor reads the failure information using the I2C-bus. The I2C-bus bits are set for a short circuit. These bits can be reset with the I2C-bus read command. Even after the short has been removed, the microprocessor knows what was wrong after reading the I2C-bus. In principle, during a single I2C-bus read command, the old information is read. To read the current information, two read commands must be sent, one-after-another. When selected, pin DIAG gives the current diagnostic information. Pin DIAG is released instantly when the failure is removed, independent of the I2C-bus latches. Table 11. Diagnostic Power-on reset UVP or OVP Clip detection Temperature pre-warning OCP DCP OTP Available data at DIAG and CLIP pin I2C-bus mode DIAG yes yes no no yes selectable yes CLIP no no selectable selectable no no no Non-I2C-bus mode DIAG yes yes no no yes yes yes CLIP no no yes yes no no no When OCP is triggered, the open-drain DIAG output is activated. The diagnostic output signal during different short circuit conditions is illustrated in Figure 16. shorted load AMPLIFIER RESTART short to GND or VP line NO RESTART pull up V AGND = 0 V 50 ms 50 ms 50 ms 001aai786 Fig 16. Diagnostic output for short circuit conditions TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 18 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 8.6.2 Load identification (I2C-bus mode only) 8.6.2.1 DC load detection DC load detection is only available in I2C-bus mode and is controlled using bit IB2[D2]. The default setting is logic 0 for bit IB2[D2] which disables DC load detection. DC load detection is enabled when bit IB2[D2] = 1. Load detection takes place before the class-D amplifier output stage starts switching in Mute mode (see Figure 17) and the start-up time from Standby mode to Mute mode is increased by tdet(DCload) VP DRIVER HIGH PWM CONTROL DRIVER LOW B OUTN PGND1 RL VP DRIVER HIGH PWM CONTROL DRIVER LOW OUTP PGND2 001aai787 Fig 17. DC load detection circuit out (V) out- out+ t (s) Tdet(DCload) Td(mute-off) 001aai788 Fig 18. DC load detection procedure The capacitor connected to pin SEL_MUTE (see Figure 4) is used to create an inaudible current test pulse, drawn from the positive amplifier output. The diagnostic `speaker load' (or `open load'), based on the voltage difference between pins OUTxP and OUTxN is shown in Figure 19. SPEAKER LOAD 0 25 350 OPEN LOAD 001aai789 Fig 19. DC load detection limits TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 19 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics Remark: DC load detection identifies a short circuited speaker as a valid speaker load. OCP detection, using byte DB1[D3] for channel 1 and byte DB2[D3] for channel 2, performs diagnostics on shorted loads. However, the diagnostics are performed after the DC load detection cycle has finished and once the amplifier is in Operating mode. The result of the DC load detection is stored in DB1[D4] and DB2[D4]. Table 12. 0 0 1 Interpretation of DC load detection bits OCP bits DB1[D3] and DB2[D3] 0 1 0 Meaning speaker load shorted load open load DC load bits DB1[D4] and DB2[D4] Remark: After DC load detection has been performed, the DC load valid bit DB1[D6] must be set. The DC load data bits are only valid when bit DB1[D6] = 1. When DC load detection is interrupted by a sudden large change in supply voltage (triggered by UVP or OVP) or if the amplifier hangs up, the DC load valid bit is reset to DB1[D6] = 0. The DC load enable bit DB2[D2] must be reset after the DC load protection cycle to release any amplifier hang-up. Once the DC load detection cycle has finished, DC load detection can be restarted by toggling the DC load detection enable bit IB2[D2]. However, this can only be used if both amplifier channels have not been enabled with bit IB1[D1] or bit IB2[D1]. See Section 8.6.2.2 "Recommended start-up sequence with DC load detection enabled" for detailed information. 8.6.2.2 Recommended start-up sequence with DC load detection enabled The flow diagram (Figure 20) illustrates the TDF8599's ability to perform a DC load detection without starting the amplifiers. After a DC load detection cycle finishes without setting the DC load valid bit DB1[D6], DC load detection is repeated (when bit IB2[D2] is toggled). To limit the maximum number of DC load detection cycle loops, a counter and limit have been added. The loop exits after the predefined number of cycles (COUNTMAX), if the DC load detection cycle finishes with an invalid detection. Depending on the application needs the invalid DC load detection cycle can be handled as follows: * the amplifier can be started without DC load detection * the DC load detection loop can be executed again A valid DC load detection cycle does not affect the normal amplifier start-up timing. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 20 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics IB1[D0] = 1 IB2[D2] = 1 IB1[D1] = 1 IB2[D1] = 1 I2C-bus TX startup enable DC load disable channel 1 disable channel 2 COUNT = 0 WAIT DC load IB1[D0] = 1 IB2[D2] = 1 IB1[D1] = 1 IB2[D1] = 1 I2C-bus TX startup enable DC load disable channel 1 disable channel 2 NO restart DC load DB1[D4] = 1 DB2[D4] = 1 DB1[D6] = 1 I2C-bus RX ch1 openload ch2 openload DC load valid COUNT COUNTMAX YES ERROR HANDLING COUNT = COUNT + 1 IB1[D0] = 1 IB2[D2] = 0 IB1[D1] = 1 IB2[D1] = 1 DB1[D6] = 1 DC load valid NO I2C-bus TX startup disable DC load disable channel 1 disable channel 2 start amplifier anyway YES I2C-bus TX startup disable DC load enable channel 1 enable channel 2 001aaj061 IB1[D0] = 1 IB2[D2] = 0 IB1[D1] = 0 IB2[D1] = 0 Fig 20. Recommended start-up sequence with DC load detection enabled 8.6.2.3 AC load detection AC load detection is only available in I2C-bus mode and is controlled using bit IB3[D4]. The default setting for bit IB3[D4] = 0 which disables AC load detection. When AC load detection is enabled (bit IB3[D4] = 1), the amplifier load current is measured and compared with a reference level. Pin CLIP is activated when this threshold is reached. Using this information, AC load detection can be performed using a predetermined input signal frequency and level. The frequency and signal level should be chosen so that the load current exceeds the programmed current threshold when the AC coupled load (tweeter) is present. 8.6.2.4 CLIP detection CLIP detection gives instantaneous information for clip levels 1 %. Pin CLIP is used as the output for the clip detection circuitry on both channel 1 and channel 2. Setting either bit IB1[D5] or bit IB2[D5] defines which channel reports clip information on the CLIP pin. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 21 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics In Parallel mode, disabling clip detection on both channels requires both bits to be set to bit IB1[D5] = 1 and bit IB2[D5] = 1. 8.6.3 Start-up and shutdown sequence To prevent the switch on or switch off `pop noise', a capacitor (CSVR) connected to pin SVR is used to smooth start-up and shutdown. During start-up and shutdown, the output voltage tracks the voltage on pin SVR. Increasing CSVR results in a longer start-up and shutdown time. Enhanced pop performance is achieved by muting the amplifier until the SVR voltage reaches its final value and the outputs start switching. The capacitor on the pin SEL_MUTE (CON) determines the unmute and mute timing. The voltage on pin SEL_MUTE determines the amplifier gain. Increasing CON increases the unmute and mute times. In addition, a larger CON value increases the DC load detection cycle. When the amplifier is switched off with an I2C-bus command or by pulling pin EN low, the amplifier is first muted and then capacitor (CSVR) is discharged. In Slave mode, the device enters the off state immediately after capacitor (CSVR) is discharged. In Master mode, the clock is kept active by an additional delay (td(2)) of approximately 50 ms to allow slave devices to enter off state. When an external clock is connected to pin OSCIO (in Slave mode), the clock remains active during the shutdown sequence (td(1)) to ensure that the slaved TDF8599 devices are able to enter the off state. VDDA DIAG td(1) EN ACGND td(3) IB1[D0] and IB2[D0]=0 mute on delay td(2) SEL_MUTE SVR twake OUT td(stb-mute) tdet(DCload) 001aai790 (1) Shutdown hold delay (2) Master mode shutdown delay (3) Shutdown delay Fig 21. Start-up and shutdown timing in I2C-bus mode with DC load detection TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 22 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics VDDA DIAG td(2) EN td(1) ACGND mute on delay SEL_MUTE td(3) SVR td(stb-mute) OUT 001aai791 (1) Shutdown hold delay (2) Shutdown delay (3) Master mode shutdown delay Fig 22. Start-up and shutdown timing in non-I2C-bus mode 9. I2C-bus specification TDF8599 address with hardware address select. Table 13. ADS[1] Open 100 k to ground 33 k to ground 13 k to ground 4.7 k to ground Ground [1] TDF8599 address using an external resistor A6 0 0 0 0 0 A5 1 1 1 1 1 A4 0 0 0 0 0 A3 1 1 1 1 1 A2 1 0 0 0 0 A1 0 1 1 0 0 A0 0 1 0 1 0 R/W 0 = Write to TDF8599 1 = Read from TDF8599 Non-I2C-bus mode select Required external resistor accuracy is 1 %. The information on pin ADS is latched when the amplifier starts switching. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 23 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics SCL SCL SDA SDA Mp SLAVE START (1) STOP Mp SLAVE (1) (2) 001aai792 001aai793 (1) When SDL is HIGH, SDA changes to form the start or stop condition. (1) SDA is allowed to change. (2) All data bits must be valid on the positive edges of the SCL. Fig 23. I2C-bus start and stop conditions Fig 24. Data bits sent from Master microprocessor (Mp) SCL 1 2 7 8 9 1 2 7 8 9 SDA MSB MSB-1 LSB+1 ACK MSB MSB-1 LSB+1 LSB ACK Mp START SLAVE ADDRESS WRITE ACK WRITE DATA ACK(1) STOP 001aai794 (1) To stop the transfer after the last acknowledge a stop condition must be generated. Fig 25. I2C-bus write SCL 1 2 7 8 9 1 2 7 8 9 SDA MSB MSB-1 LSB+1 ACK MSB MSB-1 LSB+1 LSB Mp START SLAVE ADDRESS READ ACKNOWLEDGE READ DATA ACK(1) STOP 001aai795 (1) To stop the transfer, the last byte must not be acknowledged (SDA is HIGH) and a stop condition must be generated. Fig 26. I2C-bus read TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 24 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 9.1 Instruction bytes If R/W bit = 0, the TDF8599 expects three instruction bytes: IB1, IB2 and IB3. After a power-on reset, all instruction bits are set to zero. Table 14. Bit D7 D6 D5 D4 D3 Instruction byte descriptions Description Instruction byte IB1 0 1 0 1 0 1 0 1 0 1 D2 D1 D0 0 1 0 1 0 1 [1] [2] [3] Value Instruction byte IB2 offset protection on offset protection off channel 2 offset monitoring on channel 2 offset monitoring off channel 2 clip detect on CLIP channel 2 no clip detect on CLIP thermal pre-warning on CLIP no thermal pre warning on CLIP temperature pre-warning on 140 C temperature pre-warning on 120 C DC-load detection disabled DC-load detection enabled Instruction byte IB3 offset detection on DIAG no offset detection on DIAG channel 1 offset monitoring on channel 1 offset monitoring off channel 1 clip detect on CLIP channel 1 no clip detect on CLIP disable frequency hopping enable frequency hopping[1] oscillator frequency as set with Rosc - 10 % oscillator frequency as set with Rosc + 10 % disable AC load detection enable AC load detection [2] [2] channel 1 enabled channel 1 disabled TDF8599 in standby TDF8599 in mute or operating[3] channel 2 enabled channel 2 disabled all channels operating all channels muted [2] AD modulation BD modulation See Section 8.3.3 on page 10 for information on IB1[D3]. See Table 15 "Frequency bit settings" for information. See Table 4, Table 5 and Table 16 for information on IB2[D0]. Table 15. D3 0 0 0 0 1 1 Frequency bit settings D2 0 0 1 1 0 0 D1 0 1 0 1 0 1 Phase 0 1 4 1 3 1 2 2 3 3 4 TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 25 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 9.2 Data bytes If R/W = 1, the TDF8599 sends two data bytes to the microprocessor (DB1 and DB2). All short diagnostic and offset protection bits are latched. In addition, all bits are reset after a read operation except the DC load detection bits (DBx[D4], DB1[D6]). The default setting for all bits is logic 0. In Parallel mode, the diagnostic information is stored in byte DB1. Table 16. Bit D7 0 1 D6 D5 D4 D3 D2 D1 D0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Description of data bytes DB1 channel 1 at least 1 instruction bit set to logic 1 all instruction bits are set to logic 0 invalid DC load data valid DC load data no overvoltage overvoltage protection active speaker load channel 1 open load channel 1 no shorted load shorted load channel 1 no offset offset detected no short to Vp channel 1 short to Vp channel 1 no short to ground channel 1 short to ground channel 1 DB2 channel 2 below maximum temperature maximum temperature protection activated no temperature warning temperature pre-warning active no undervoltage undervoltage protection active speaker load channel 2 open load channel no shorted load shorted load channel 2 reserved reserved no short to Vp channel 2 short to Vp channel 2 no short to ground channel 2 short to ground channel 2 Value Data byte DB1[D7] indicates whether the instruction bits have been set to logic 0. In principle, DB1[D7] is set after a POR or when all the instruction bits are programmed to logic 0. Pin DIAG is activated when bit IB1[D7] = 1. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 26 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 10. Limiting values Table 17. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134). Symbol VP Parameter supply voltage Conditions Operating mode off state load dump; duration 50 ms, tr >2.5 ms IORM IOM Vi repetitive peak output current peak output current input voltage maximum output current limiting maximum; non-repetitive pins SCL, SDA, ADS, MOD, SSM, OSCIO, EN and SEL_MUTE pins DIAG and CLIP [2] [1] Min -1 8 0 Max 18 50 50 12 5.5 Unit V V V A A V [2] Vo Tj Tstg Tamb VESD output voltage junction temperature storage temperature ambient temperature electrostatic discharge voltage 0 -55 -40 10 150 +150 +85 2000 V C C C V HBM C = 100 pF; Rs = 1500 CDM non-corner pins corner pins [3] [4] [5] 500 750 Vp V V V V(prot) protection voltage AC and DC short circuit voltage of output pins across load and to supply and ground Tcase = 70 C 0 Pmax [1] [2] [3] [4] [5] maximum power dissipation - 15 W Floating condition assumed for outputs. Current limiting concept. Human Body Model (HBM). Charged-Device Model (CDM). The output pins are defined as the output pins of the filter connected between the TDF8599 output pins and the load. 11. Thermal characteristics Table 18. Symbol Rth(j-a) Rth(j-c) Thermal characteristics Parameter thermal resistance from junction to ambient thermal resistance from junction to case Conditions in free air Typ 35 1 Unit K/W K/W TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 27 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 12. Static characteristics Table 19. Static characteristics Vp = 14.4 V; fosc = 320 kHz; -40 C < Tamb < +85 C; unless otherwise specified. Symbol Supply VP IP Istb Iq(tot) supply voltage supply current standby current total quiescent current off state; Tj 85 C; VP = 14.4 V voltage on pin EN < 0.8 V Operating mode; no load, snubbers and filter connected power switch; Tj = 25 C Tj = 100 C I2C-bus interface: pins SCL and SDA VIL VIH VOL Vi Ii Vi LOW-level input voltage HIGH-level input voltage LOW-level output voltage input voltage input current input voltage pin SDA; Iload = 5 mA pins not connected pins shorted to GND pin EN; off state pin EN; Standby mode; mode I2C-bus [1] [1] Parameter Conditions Min 8 - Typ Max Unit V A A mA 14.4 18 2 90 10 10 120 Series resistance output switches RDSon drain-source on-state resistance 0 2.3 0 1.5 80 0 2 2 0 3 130 170 2 120 1.5 5.5 0.4 2.7 160 0.8 5 5 0.8 5 5 50 m m V V V V A V V V V V A A Address, phase shift and modulation mode select: pins ADS and MOD Enable and SEL_MUTE input: pins EN and SEL_MUTE pin EN; Mute mode or Operating mode; non-I2C-bus mode pin SEL_MUTE; Mute mode; voltage on pin EN > 2 V pin SEL_MUTE; Operating mode; voltage on pin EN > 2 V Ii input current pin EN; 2.5 V pin SEL_MUTE; Operating mode; 0.8 V Diagnostic output THDclip Vth(offset) VOL IL total harmonic distortion clip detection level threshold voltage for offset detection LOW-level output voltage leakage current DIAG or CLIP pins activated; Io = 1 mA DIAG and CLIP pins; diagnostic not activated [2] 1 - 0.2 2 - 3 0.3 50 % V V A Audio inputs; pins IN1N, IN1P, IN2N and IN2P Vi TDF8599_1 input voltage - 2.45 - V (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 28 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics Table 19. Static characteristics ...continued Vp = 14.4 V; fosc = 320 kHz; -40 C < Tamb < +85 C; unless otherwise specified. Symbol Vref Parameter reference voltage Conditions input ACGND pin half supply reference SVRR pin Amplifier outputs; pins OUT1N, OUT1P, OUT2N and OUTP2 VO(offset) output offset voltage BTL; Mute mode BTL; Operating mode Stabilizer output; pins VSTAB1 and VSTAB2 Vo output voltage stabilizer output in Mute mode and Operating mode undervoltage; amplifier is muted overvoltage; load dump protection is activated VP that a POR occurs at Current protection IO(ocp) overcurrent protection output current protection temperature thermal foldback activation temperature average junction temperature for pre-warning 1 average junction temperature for pre-warning 2 load detection threshold impedance open load detection threshold impedance AC load detection output threshold current wake-up time DC load detection time delay time from standby to mute on pin EN before first I2C-bus transmission is recognized CON = 470 nF measured from amplifier enabling to start of mute release (no DC load detection); CSVR = 47 F CON = 470 nF CON = 470 nF [5] [4] [3][5] Min 2 6.9 8 Typ Max Unit V V mV mV V SVRR voltage and ACGND input bias voltage in Mute and Operating modes 2.45 3 7.2 10 7.5 25 70 12 Voltage protections V(prot) protection voltage 6.8 7.2 8 4.4 V V V A 26.2 27 3 8 3.7 - current limit Temperature protection Tprot Tact(th_fold) Tj(AV)(warn1) Tj(AV)(warn2) 155 gain = -1 dB IB2[D3] = 0; non-I2C-bus mode IB2[D3] = 1 140 140 120 160 150 150 130 C C C C DC load detection levels: I2C-bus mode only[6] Zth(load) Zth(open) for normal speaker; DB1[D4] = 0; DB2[D4] = 0 DB1[D4] = 1; DB2[D4] = 1 350 25 AC load detection levels: I2C-bus mode only Ith(o)det(load)AC 700 900 1100 mA Start-up/shut-down/mute timing twake tdet(DCload) td(stb-mute) 250 140 500 s ms ms [4] td(mute-fgain) mute to full gain delay time - 15 - ms TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 29 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics Table 19. Static characteristics ...continued Vp = 14.4 V; fosc = 320 kHz; -40 C < Tamb < +85 C; unless otherwise specified. Symbol td Parameter delay time Conditions shutdown delay time from EN pin low to SVRR low; SVRR < 0.1 V; CSVR = 47 F shutdown delay time from pin EN low to ACGND low; voltage on pin ACGND < 0.1 V; Master mode delay in Master mode to allow slaved devices to shutdown fosc = 320 kHz Speaker load impedance RL load resistance stereo mode parallel mode [1] [2] [3] [4] [5] [6] Required resistor accuracy for pins ADS and MOD is 1 %; see Section 9 on page 23. Maximum leakage current from DCP pin to ground = 3 A. DC output offset voltage is applied to the output during the transition between Mute mode and Operating mode in a gradual way. I2C-bus mode only. The transition time between Mute mode and Operating mode is determined by the time constant on the SEL_MUTE pin. The DC load valid bit DB1[D6] must be used; Section 8.6.2.1 on page 19. The DC load enable bit IB2[D2] must be reset after each load detection cycle to prevent amplifier hang-up incidents. Min 145 Typ 260 Max 425 Unit ms - 400 - ms - 50 - ms 1.6 0.8 4 - - TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 30 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 12.1 Switching characteristics Table 20. Switching characteristics VP = 14.4 V; -40 C < Tamb < +85 C; unless otherwise specified. Symbol fosc Parameter oscillator frequency Conditions external clock frequency; Rosc = 39 k internal fixed frequency and Spread spectrum mode frequency Master/slave setting (OSCIO pin) Rosc VOL VOH VIL VIH ftrack Nslave fosc oscillator resistance LOW-level output voltage HIGH-level output voltage LOW-level input voltage HIGH-level input voltage tracking frequency number of slaves oscillator frequency variation resistor value on pin OSCSET; master setting output output input input PLL enabled driven by one master between maximum and minimum values; Spread spectrum mode activated Spread spectrum mode activated; CSSM = 1 F change positive; IB1[D4] = 1; IB1[D3] = 0 change negative; IB1[D4] = 1; IB1[D3] = 1 Timing tr tf tw(min) rise time fall time minimum pulse width PWM output; Io = 0 PWM output; Io = 0 Io = 0 10 80 80 ns ns ns 26 4 4 300 39 10 49 0.8 0.8 500 12 % k V V V V kHz Min 300 Typ 320 Max 500 Unit kHz kHz Internal oscillator Spread spectrum mode setting fsw switching frequency - 7 - Hz Frequency hopping fosc(int) internal oscillator frequency fosc + 10 % fosc - 10 % kHz kHz TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 31 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 13. Dynamic characteristics Table 21. Dynamic characteristics Vp = 14.4 V; RL = 4 ; fi = 1 kHz; fosc = 320 kHz; RsL < 0.04 [1]; -40 C < Tamb < +85 C; Stereo mode; unless otherwise specified. Symbol Po Parameter output power Conditions Stereo mode; THD = 1 %; RL = 4 THD = 10 %; RL = 4 square wave (EIAJ); RL = 4 THD = 1 %; RL = 2 THD = 10 %; RL = 2 square wave (EIAJ); RL = 2 Parallel mode THD = 10 %; RL = 1 THD Gv(cl) cs SVRR total harmonic distortion closed-loop voltage gain channel separation supply voltage rejection ratio fi = 1 kHz; Po = 1 W Operating mode fripple = 100 Hz fripple = 1 kHz Mute mode fripple = 1 kHz off state and Standby mode fripple = 1 kHz |Zi(dif)| Vn(o) differential input impedance output noise voltage Operating mode BD mode AD mode Mute mode BD mode AD mode bal(ch) mute CMRR po [1] [6] [6] [5] [5] [4] [4] [4] [4] [2] [3] [3] [2] Min 18 24 29 39 25 60 [7] Typ 20 26 40 32 43 70 85 0.02 0.02 26 70 70 70 70 90 100 60 100 25 85 0 80 90 Max 0.1 0.1 27 150 77 140 32 110 1 - Unit W W W W W W W % % dB dB dB dB dB dB k V V V V dB dB dB % fi = 1 kHz; Po = 1 W fi = 10 kHz; Po = 1 W channel balance mute attenuation common mode rejection ratio output power efficiency Vi(CM) = 1 V RMS Po = 20 W 66 65 - RS(L) is the sum of the inductor series resistance from the low-pass LC filter in the application together with all resistance from PCB traces or wiring between the output pin of the TDF8599 and the inductor to the measurement point. LC filter dimensioning is L = 10 H, C = 1 F is used and for 2 load L = 5 H, C = 2.2 F for 4 load. Output power is measured indirectly based on RDSon measurement. Total harmonic distortion is measured at the bandwidth of 22 Hz to 20 kHz, AES brick wall. The maximum limit is guaranteed but may not be 100 % tested. Vripple = Vripple(max) = 1 V RMS; Rs = 0 . (c) NXP B.V. 2008. All rights reserved. [2] [3] [4] TDF8599_1 Product data sheet Rev. 01 -- 13 November 2008 32 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics [5] [6] [7] B = 22 Hz to 20 kHz, AES brick wall, Rs = 0 . B = 22 Hz to 20 kHz, AES brick wall, independent of Rs. Vi = Vi(max) = 0.5 V RMS. 14. Application information 14.1 Output power estimation (Stereo mode) The output power, just before clipping, can be estimated using the following equations: 2 RL f osc ----------------------------------------------------- x 1 - t x --------- x V p - - W ( min ) R L + 2 x ( R DSon + R S ) 2 P o = ---------------------------------------------------------------------------------------------------------------------------------------2 x RL (5) Where, * * * * * * * Po = 0.5 % VP = supply voltage (V) RL = load impedance () RDSon = on-resistance power switch () RS = series resistance output inductor () tW(min) = minimum pulse width(s) depending on output current fosc = oscillator frequency in Hz (typically 320 kHz) The output power at 10 % THD can be estimated by: P 0 ( 2 ) = 1.25 x P o ( 1 ) Where Po(1) = 0.5 % and Po(2) = 10 %. Figure 27 and Figure 28 show the estimated output power at THD = 0.5 % and THD = 10 % as a function of supply voltage for different load impedances at stereo mode. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 33 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 80 Po (W) 60 001aai796 80 Po (W) 60 001aai797 40 (1) (2) 40 (1) (2) 20 (3) 20 (3) 0 8 10 12 14 16 VP (V) 18 0 8 10 12 14 16 VP (V) 18 THD = 0.5 %. (1) RDSon = 0.12 (at Tj = 25 C), RS = 0.025 , tW(min) = 130 ns and IO(ocp) = 8 A (minimum). (2) RL = 1 . (3) RL = 2 . (4) RL = 4 . THD = 10 %. (1) RDSon = 0.12 (at Tj = 25 C), RS = 0.025 , tW(min) = 130 ns and IO(ocp) = 8 A (minimum). (2) RL = 1 . (3) RL = 2 . (4) RL = 4 . Fig 27. Po as a function of Vp in stereo mode with THD = 0.5 % Fig 28. Po as a function of Vp in stereo mode with THD = 10 % TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 34 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 14.2 Output power estimation (Parallel mode) Figure 29 and Figure 30 show the estimated output power at THD = 0.5 % and THD = 10 % as a function of the supply voltage for different load impedances in parallel mode. 160 Po (W) 120 001aai798 160 Po (W) 120 001aai799 (1) (1) 80 (2) 80 (2) 40 (3) 40 (3) 0 8 10 12 14 16 VP (V) 18 0 8 10 12 14 16 VP (V) 18 THD = 0.5 %. (1) RDSon = 0.06 (at Tj = 25 C), RS = 0.0125 , tW(min) = 130 ns and IO(ocp) = 16 A (minimum). (2) RL = 1 . (3) RL = 2 . (4) RL = 4 . THD = 10 %. (1) RDSon = 0.06 (at Tj = 25 C), RS = 0.0125 , tW(min) = 130 ns and IO(ocp) = 16 A (minimum). (2) RL = 1 . (3) RL = 2 . (4) RL = 4 . Fig 29. Po as a function of Vp in parallel mode with THD = 0.5 % Fig 30. Po as a function of Vp parallel mode with THD = 10 % 14.3 Output current limiting The peak output current is internally limited to 8 A maximum. During normal operation, the output current should not exceed this threshold level otherwise the output signal will be distorted. The peak output current can be estimated using the following equation: Vp I o ----------------------------------------------------- 8 A R L + 2 x ( R RSon + R S ) (6) * * * * * Io = output current (A) VP = supply voltage (V) RL = load impedance () RDSon = on-resistance power switch () RS = series resistance output inductor () Example: A 1 speaker can be used with a supply voltage of 11 V before current limiting is triggered. Current limiting (clipping) avoids audio holes but can cause distortion similar to voltage clipping. In Parallel mode, the output current is internally limited above 16 A. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 35 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 14.4 Speaker configuration and impedance A flat-frequency response (due to a 2nd order Butterworth filter) is obtained by changing the low-pass filter components (LLC, CLC) based on the speaker configuration and impedance. Table 22 shows the required values. Table 22. 1 2 4 Filter components values LLC (H) 2.5 5 10 CLC (F) 4.4 2.2 1 Load impedance () Remark: When using a 1 load impedance in Parallel mode, the outputs are shorted after the low-pass filter switches two 2 filters in parallel. 14.5 Heat sink requirements In some applications, it may be necessary to connect an external heat sink to the TDF8599. Thermal foldback activates at Tj = 145 C. The expression below shows the relationship between the maximum power dissipation before activation of thermal foldback and the total thermal resistance from junction to ambient; T j ( max ) - T amb R th ( j - a ) = ----------------------------------P max (7) Pmax is determined by the efficiency () of the TDF8599. The efficiency measured as a function of output power is given in Figure 39. The power dissipation can be derived as a function of output power (see Figure 32). Example 1: * * * * * * Vp = 14.4 V Po = 2 x 25 W into 4 (THD = 10 % continuous) Tj(max) = 140 C Tamb = 25 C Pmax = 5.8 W (from Figure 39) The required Rth(j-a) = 115 C/5.8 W = 19 K/W The total thermal resistance Rth(j-a) consists of: * Rth(j-c) + Rth(c-h) + Rth(h-a) Where: * Thermal resistance from junction to case (Rth(j-c)) = 1.1 K/W * Thermal resistance from case to heat sink (Rth(c-h)) = 0.5 - 1 K/W (depending on mounting) * Thermal resistance from heat sink to ambient (Rth(h-a)) would then be 19 - (1.1 + 1) = 17 K/W. If an audio signal has a crest factor of 10 (the ratio between peak power and average power = 10 dB) then Tj will be much lower. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 36 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics Example 2: * * * * * * Vp = 14.4 V Po = 2 x (25 W/10) = 2 x 2.5 W into 4 (audio with crest factor of 10) Tamb = 25 C Pmax = 2.5 W (from Figure 39) Rth(j-a) = 19 K/W Tj(max) = 25 C + 2.5 W x 19 K/W = 72 C 14.6 Curves measured in reference design 102 % 10 001aai800 102 % 10 001aai801 1 1 10-1 (1) 10-1 (1) (2) 10-2 (3) 10-2 (2) (3) 10-3 10-1 1 10 W 102 10-3 10-1 1 10 W 102 (1) VP = 14.4 V; RL = 2 at 6 kHz. (2) VP = 14.4 V; RL = 2 at 1 kHz. (3) VP = 14.4 V, RL = 2 at 100 Hz. (1) VP = 14.4 V; RL = 4 at 6 kHz. (2) VP = 14.4 V; RL = 4 at 1 kHz. (3) VP = 14.4 V, RL = 4 at 100 Hz. Fig 31. THD + N as a function of output power Fig 32. THD + N as a function of output power TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 37 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 1 % 001aai802 1 % 001aai803 10-1 10-1 (1) (1) 10-2 (2) 10-2 (2) 10-3 10 102 103 104 Hz 105 10-3 10 102 103 104 Hz 105 (1) VP = 14.4 V; RL = 2 at 10 W. (2) VP = 14.4 V; RL = 2 at 1 W. (1) VP = 14.4 V; RL = 4 at 10 W. (2) VP = 14.4 V; RL = 4 at 1 W. Fig 33. THD + N as a function of frequency with a 2 load Fig 34. THD + N as a function of frequency with a 4 load -60 dB -70 001aai804 -60 dB -70 001aai805 -80 (1) -80 (1) (2) -90 -90 (2) -100 10 102 103 104 Hz 105 -100 10 102 103 104 Hz 105 PO = 1 W; VP = 14.4 V; RL = 2 . (1) Channel 1 to channel 2. (2) Channel 2 to channel 1. PO = 1 W; VP = 14.4 V; RL = 4 . (1) Channel 1 to channel 2. (2) Channel 2 to channel 1. Fig 35. Channel separation as a function of frequency with a 2 load Fig 36. Channel separation as a function of frequency with a 4 load TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 38 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics -75 CMRR (dB) -80 001aai806 A (dBr) 1.0 0.8 0.6 0.4 001aai807 (2) (1) 0.2 0 -0.2 -85 -0.4 -0.6 -0.8 (1) (2) -90 10-2 10-1 1 10 kHz 102 -1.0 10 102 103 104 Hz 105 Vi = 1 V; Ri = 0 . (1) VP = 14.4 V; RL = 2 . (2) VP = 14.4 V; RL = 4 . Vi =100 mV RMS; Ri = 0 . (1) VP = 14.4 V; RL = 2 . (2) VP = 14.4 V; RL = 4 . Fig 37. CMRR as a function of frequency Fig 38. Gain as a function of frequency 100 n (%) 80 (2) (1) 001aai808 20 PD (W) 16 001aai809 60 12 (1) 40 8 (2) 20 4 0 0 10 20 30 40 50 60 Po (W) 0 0 20 40 Po (W) 60 (1) VP = 14.4 V; RL = 2 at 1 kHz. (2) VP = 14.4 V; RL = 4 at 1 kHz. (1) VP = 14.4 V; RL = 2 at 1 kHz. (2) VP = 14.4 V; RL = 4 at 1 kHz. Fig 39. Efficiency as a function of Po Fig 40. Power dissipation as a function of total output power TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 39 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 14.7 Typical application schematics bead bead bead VP GND PGND2 GNDD/HW 100 nF 220 nF LLC 1000 F 35 V 100 F 35 V 100 F 35 V VP1 VP2 VPA PGND1 36 35 34 33 32 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 IN1P CIN1P IN1N CIN1N IN2P CIN2P 470 nF 470 nF 470 nF 470 nF IN1P IN1N IN2P IN2N VDDD VSTAB1 OUT1N OUT1N 100 nF 22 470 pF 470 pF CLC 10 15 nF IN2N CIN2N ACGND EN BOOT1N VP1 CACGND 100 nF VP1 100 nF enable(1) mute/on(1) 470 nF 47 F 100 nF VP1 22 100 nF 470 pF CLC LLC LLC PGND1 470 pF 10 PGND1 30 PGND1 BOOT1P 29 OUT1P OUT2P 28 SEL_MUTE SVRR AGND VDDA ADS MOD CLIP DIAG SDA SCL SSM OSCSET 1 F(2) 100 nF 39 k 4.7 k 10 k 15 nF OUT1P OUT2P 100 nF 22 TDF8599 27 26 25 24 23 22 21 20 19 CLC 10 15 nF bead VPA non-I2C-bus mode BD modulation setting VPA BOOT2P 470 pF 470 pF 470 pF 10 PGND2 PGND2 100 nF VP2 22 100 nF 470 pF CLC LLC PGND2 VP2 VP2 BOOT2N 10 k VPA 15 nF 220 nF OUT2N OUT2N VSTAB2 DCP OSCIO (3) MASTER MODE 001aai810 Dual BTL mode (stereo) in non-I2C-bus mode with DC offset protection disabled Spread spectrum mode enabled BD modulation. (1) See Figure 4 on page 7 for a diagram of the connection for pins EN and SEL_MUTE. (2) See Section 8.3.2 on page 9 for detailed information. (3) See Section 8.5.5 on page 16 for detailed information on disabling DC offset protection. Fig 41. Example application diagram for dual BTL in non-I2C-bus mode TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 40 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics bead bead bead VP GND PGND2 GNDD/HW 100 nF 220 nF LLC 1000 F 35 V 100 F 35 V 100 F 35 V VP1 VP2 VPA PGND1 36 35 34 33 32 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 IN1P CIN1P IN1N CIN1N IN2P CIN2P IN2N CIN2N ACGND EN 470 nF 470 nF 470 nF 470 nF IN1P IN1N IN2P IN2N VDDD VSTAB1 OUT1N OUT1N 100 nF 22 470 pF 470 pF CLC 10 15 nF BOOT1N VP1 CACGND 100 nF VP1 100 nF enable(1) VP1 22 100 nF 470 pF CLC LLC LLC PGND1 470 pF 10 PGND1 30 PGND1 BOOT1P 29 OUT1P OUT2P 28 SEL_MUTE(1) SVRR AGND VDDA ADS MOD CLIP DIAG SDA SCL SSM OSCSET 100 nF 39 k 100 nF 470 nF 47 F 15 nF OUT1P OUT2P 100 nF 22 TDF8599 27 26 25 24 23 22 21 20 19 CLC 10 15 nF BOOT2P bead Rads 33 k 10 k VPA I2C-bus address select stereo mode setting VPA 470 pF 470 pF 470 pF 10 PGND2 PGND2 100 nF VP2 22 100 nF 470 pF CLC LLC PGND2 VP2 VP2 BOOT2N 10 k VPA connect with P (2) 15 nF 220 nF OUT2N OUT2N VSTAB2 DCP (3) 4.7 F OSCIO MASTER MODE 001aai811 Dual BTL mode (stereo) in non-I2C-bus mode with DC offset protection enabled Spread spectrum mode disabled. (1) See Figure 4 on page 7 for a diagram of the connection for pins EN and SEL_MUTE. (2) See Section 8.3.2 on page 9 for detailed information. (3) See Section 8.5.5 on page 16 for detailed information on disabling DC offset protection. Fig 42. Example application diagram for dual BTL in I2C-bus mode TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 41 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics bead bead bead VP GND PGND2 GNDD/HW 100 nF 220 nF LLC 10 15 nF 1000 F 35 V 100 F 35 V 100 F 35 V VP1 VP2 VPA PGND1 36 35 34 33 32 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 IN1P IN1N IN2P IN2N ACGND EN CINP CINN 470 nF 470 nF INP INN VDDD VSTAB1 OUT1N BOOT1N VP1 CACGND 100 nF 470 pF 470 pF VP1 100 nF enable(1) OUTN 100 nF CLC VP1 470 pF PGND1 470 pF 10 PGND1 30 PGND1 BOOT1P 29 OUT1P OUT2P 28 SEL_MUTE(1) SVRR AGND VDDA ADS MOD CLIP DIAG SDA SCL SSM OSCSET 100 nF 39 k 100 nF 470 nF 47 F 22 LLC LLC 15 nF TDF8599 27 26 25 24 23 22 21 20 19 22 CLC 470 pF 10 15 nF BOOT2P bead Rads 100 k 10 k VPA I2C-bus address select parallel mode setting VPA 100 nF 470 pF 470 pF 10 PGND2 PGND2 100 nF OUTP VP2 470 pF PGND2 VP2 VP2 BOOT2N 10 k VPA connect with P fixed frequency(2) MASTER MODE 001aai812 LLC 15 nF 220 nF OUT2N VSTAB2 DCP (3) 4.7 F OSCIO Single BTL mode (parallel) in I2C-bus mode with DC offset protection enabled Spread spectrum mode disabled. (1) See Figure 4 on page 7 for a diagram of the connection for pins EN and SEL_MUTE. (2) See Section 8.3.2 on page 9 for detailed information. (3) See Section 8.5.5 on page 16 for detailed information on disabling DC offset protection. Fig 43. Example application diagram for a single BTL in I2C-bus mode TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 42 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics bead bead bead VP GND 1000 F 35 V 100 F 35 V 100 F 35 V VP1 VP2 GNDD/HW 100 nF 220 nF VPA PGND1 PGND2 LLC 36 35 34 33 32 31 30 29 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 IN1P CIN1P IN1N CIN1N IN2P CIN2P IN2N CIN2N ACGND EN(1) 470 nF 470 nF 470 nF 470 nF IN1P IN1N IN2P IN2N VDDD VSTAB1 OUT1N OUT1N 100 nF 22 470 pF 470 pF CLC 10 15 nF BOOT1N VP1 PGND1 CACGND 100 nF VP1 100 nF enable VP1 22 100 nF 470 pF CLC LLC LLC PGND1 470 pF 10 SEL_MUTE(1) SVRR AGND VDDA ADS MOD CLIP DIAG SDA SCL SSM OSCSET 1 F 100 nF 39 k 100 nF 470 nF 47 F PGND1 BOOT1P OUT1P OUT2P 15 nF OUT1P OUT2P 100 nF 22 TDF8599 27 26 25 24 23 22 21 20 19 CLC 10 15 nF BOOT2P bead Rads 33 k 10 k VPA I2C-bus address select stereo mode setting VPA 470 pF 470 pF 470 pF 10 PGND2 PGND2 100 nF VP2 22 100 nF 470 pF CLC LLC PGND2 VP2 VP2 BOOT2N 10 k VPA 15 nF 220 nF OUT2N OUT2N VSTAB2 DCP DC offset protection enabled (3) 20 k 4.7 F OSCIO spread spectrum mode(2) MASTER MODE GNDD/HW 100 nF 220 nF LLC 10 15 nF 36 35 34 33 32 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 IN1P IN1N IN2P IN2N ACGND EN(1) Cin Cin 470 nF 470 nF IN3P IN3N VDDD VSTAB1 OUT1N BOOT1N VP1 CACGND 100 nF 470 pF 470 pF VP1 100 nF OUT3N 100 nF CLC VP1 470 pF PGND1 470 pF 10 PGND1 30 PGND1 BOOT1P 29 OUT1P OUT2P 28 SEL_MUTE(1) SVRR AGND VDDA ADS MOD CLIP DIAG SDA SCL SSM OSCSET 5.1 k 270 nF 100 nF 470 nF 47 F 22 LLC LLC 15 nF TDF8599 27 26 25 24 23 22 21 20 19 22 CLC 470 pF 10 15 nF BOOT2P bead Rads 100 k 10 k VPA I2C-bus address select parallel mode setting VPA 100 nF 470 pF 470 pF 10 PGND2 PGND2 100 nF OUT3P VP2 470 pF PGND2 VP2 VP2 BOOT2N 10 k VPA connect with P phase lock operation (2) LLC 15 nF 220 nF OUT2N VSTAB2 DCP DC offset protection enabled (3) 4.7 F OSCIO 10 nF SLAVE MODE 001aai813 I2C-bus mode: Single BTL in Master mode with two BTLs in Slave mode; DC offset protection enabled. (1) See Figure 4 on page 7 for a diagram of the connection for pins EN and SEL_MUTE. (2) See Section 8.3.2 on page 9 for detailed information. (3) See Section 8.5.5 on page 16 for detailed information on disabling DC offset protection. Fig 44. Master-slave example application diagram; one BTL master and two BTL slaves in I2C-bus mode TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 43 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 15. Package outline HSOP36: plastic, heatsink small outline package; 36 leads; low stand-off height SOT851-2 D x E A c y E2 HE X v M A D1 D2 1 18 pin 1 index Q E1 A2 (A 3) A4 Lp detail X 36 z e 19 w A bp M 0 5 scale 10 mm DIMENSIONS (mm are the original dimensions) A UNIT max. A2 mm 3.5 A3 A4(1) bp c D (2) D1 D2 1.1 0.9 E (2) 11.1 10.9 E1 6.2 5.8 E2 2.9 2.5 e 0.65 HE 14.5 13.9 Lp 1.1 0.8 Q 1.7 1.5 v w x y Z 2.55 2.20 8 0 +0.08 3.5 0.35 -0.04 3.2 0.38 0.32 16.0 13.0 0.25 0.23 15.8 12.6 0.25 0.12 0.03 0.07 Notes 1. Limits per individual lead. 2. Plastic or metal protrusions of 0.25 mm maximum per side are not included. OUTLINE VERSION SOT851-2 REFERENCES IEC JEDEC JEITA EUROPEAN PROJECTION ISSUE DATE 04-05-04 Fig 45. Package outline SOT851-2 (HSOP36) TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 44 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics HSOP36: plastic, heatsink small outline package; 36 leads; low stand-off height SOT938-1 E D E2 A X c y HE v M A D1 D2 36 19 Q E1 pin index A1 A4 A2 (A3) Lp detail X 1 18 A Z e bp w M 0 5 scale 10 mm y 0.1 Z 2.55 2.20 8 0 DIMENSIONS (mm are the original dimensions) UNIT mm A max 3.6 A1 0.3 0.1 A2 3.3 3.0 A3 0.35 A4(1) 0.1 0 bp 0.38 0.25 c 0.32 0.23 D (2) 16.0 15.8 D1 13.0 12.6 D2 1.1 0.9 E (2) 11.1 10.9 E1 6.2 5.8 E2 2.9 2.5 e 0.65 HE 14.5 13.9 Lp 1.1 0.8 Q 1.5 1.4 v 0.25 w 0.12 Notes 1. Limits per individual lead. 2. Plastic or metal protrusions of 0.25 mm maximum per side are not included. OUTLINE VERSION SOT938-1 REFERENCES IEC JEDEC JEITA EUROPEAN PROJECTION ISSUE DATE 06-01-20 06-04-07 Fig 46. Package outline SOT938-1 (HSOP36) TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 45 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 16. Handling information In accordance with SNW-FQ-611-D. The number of the quality specification can be found in the Quality Reference Handbook. The handbook can be ordered using the code 9398 510 63011. 17. Soldering of SMD packages This text provides a very brief insight into a complex technology. A more in-depth account of soldering ICs can be found in Application Note AN10365 "Surface mount reflow soldering description". 17.1 Introduction to soldering Soldering is one of the most common methods through which packages are attached to Printed Circuit Boards (PCBs), to form electrical circuits. The soldered joint provides both the mechanical and the electrical connection. There is no single soldering method that is ideal for all IC packages. Wave soldering is often preferred when through-hole and Surface Mount Devices (SMDs) are mixed on one printed wiring board; however, it is not suitable for fine pitch SMDs. Reflow soldering is ideal for the small pitches and high densities that come with increased miniaturization. 17.2 Wave and reflow soldering Wave soldering is a joining technology in which the joints are made by solder coming from a standing wave of liquid solder. The wave soldering process is suitable for the following: * Through-hole components * Leaded or leadless SMDs, which are glued to the surface of the printed circuit board Not all SMDs can be wave soldered. Packages with solder balls, and some leadless packages which have solder lands underneath the body, cannot be wave soldered. Also, leaded SMDs with leads having a pitch smaller than ~0.6 mm cannot be wave soldered, due to an increased probability of bridging. The reflow soldering process involves applying solder paste to a board, followed by component placement and exposure to a temperature profile. Leaded packages, packages with solder balls, and leadless packages are all reflow solderable. Key characteristics in both wave and reflow soldering are: * * * * * * Board specifications, including the board finish, solder masks and vias Package footprints, including solder thieves and orientation The moisture sensitivity level of the packages Package placement Inspection and repair Lead-free soldering versus SnPb soldering 17.3 Wave soldering Key characteristics in wave soldering are: TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 46 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics * Process issues, such as application of adhesive and flux, clinching of leads, board transport, the solder wave parameters, and the time during which components are exposed to the wave * Solder bath specifications, including temperature and impurities 17.4 Reflow soldering Key characteristics in reflow soldering are: * Lead-free versus SnPb soldering; note that a lead-free reflow process usually leads to higher minimum peak temperatures (see Figure 47) than a SnPb process, thus reducing the process window * Solder paste printing issues including smearing, release, and adjusting the process window for a mix of large and small components on one board * Reflow temperature profile; this profile includes preheat, reflow (in which the board is heated to the peak temperature) and cooling down. It is imperative that the peak temperature is high enough for the solder to make reliable solder joints (a solder paste characteristic). In addition, the peak temperature must be low enough that the packages and/or boards are not damaged. The peak temperature of the package depends on package thickness and volume and is classified in accordance with Table 23 and 24 Table 23. SnPb eutectic process (from J-STD-020C) Package reflow temperature (C) Volume (mm3) < 350 < 2.5 2.5 Table 24. 235 220 Lead-free process (from J-STD-020C) Package reflow temperature (C) Volume (mm3) < 350 < 1.6 1.6 to 2.5 > 2.5 260 260 250 350 to 2000 260 250 245 > 2000 260 245 245 350 220 220 Package thickness (mm) Package thickness (mm) Moisture sensitivity precautions, as indicated on the packing, must be respected at all times. Studies have shown that small packages reach higher temperatures during reflow soldering, see Figure 47. TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 47 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics temperature maximum peak temperature = MSL limit, damage level minimum peak temperature = minimum soldering temperature peak temperature time 001aac844 MSL: Moisture Sensitivity Level Fig 47. Temperature profiles for large and small components For further information on temperature profiles, refer to Application Note AN10365 "Surface mount reflow soldering description". 18. Abbreviations Table 25. BCDMOS BTL DCP EMI I2C LSB MSB NDMOST OCP OTP OVP POR PWM SOI TFP UVP WP Abbreviations Description Bipolar Complementary and double Diffused Metal-Oxide Semiconductor Bridge-Tied Load DC offset Protection ElectroMagnetic Interference Inter-Integrated Circuit Least Significant Bit Most Significant Bit N-type double Diffused Metal-Oxide Semiconductor Transistor OverCurrent Protection OverTemperature Protection OverVoltage Protection Power-On Reset Pulse-Width Modulation Silicon On Insulator Thermal Foldback Protection UnderVoltage Protection Window Protection Abbreviation TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 48 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 19. Revision history Table 26. Revision history Release date 20081113 Data sheet status Product data sheet Change notice Supersedes Document ID TDF8599_1 TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 49 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 20. Legal information 20.1 Data sheet status Document status[1][2] Objective [short] data sheet Preliminary [short] data sheet Product [short] data sheet [1] [2] [3] Product status[3] Development Qualification Production Definition This document contains data from the objective specification for product development. This document contains data from the preliminary specification. This document contains the product specification. Please consult the most recently issued document before initiating or completing a design. The term `short data sheet' is explained in section "Definitions". The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status information is available on the Internet at URL http://www.nxp.com. 20.2 Definitions Draft -- The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. NXP Semiconductors does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information. Short data sheet -- A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local NXP Semiconductors sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail. damage. NXP Semiconductors accepts no liability for inclusion and/or use of NXP Semiconductors products in such equipment or applications and therefore such inclusion and/or use is at the customer's own risk. Applications -- Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Limiting values -- Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) may cause permanent damage to the device. Limiting values are stress ratings only and operation of the device at these or any other conditions above those given in the Characteristics sections of this document is not implied. Exposure to limiting values for extended periods may affect device reliability. Terms and conditions of sale -- NXP Semiconductors products are sold subject to the general terms and conditions of commercial sale, as published at http://www.nxp.com/profile/terms, including those pertaining to warranty, intellectual property rights infringement and limitation of liability, unless explicitly otherwise agreed to in writing by NXP Semiconductors. In case of any inconsistency or conflict between information in this document and such terms and conditions, the latter will prevail. No offer to sell or license -- Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights. Quick reference data -- The Quick reference data is an extract of the product data given in the Limiting values and Characteristics sections of this document, and as such is not complete, exhaustive or legally binding. 20.3 Disclaimers General -- Information in this document is believed to be accurate and reliable. However, NXP Semiconductors does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. Right to make changes -- NXP Semiconductors reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof. Suitability for use -- NXP Semiconductors products are not designed, authorized or warranted to be suitable for use in medical, military, aircraft, space or life support equipment, nor in applications where failure or malfunction of an NXP Semiconductors product can reasonably be expected to result in personal injury, death or severe property or environmental 20.4 Trademarks Notice: All referenced brands, product names, service names and trademarks are the property of their respective owners. I2C-bus -- logo is a trademark of NXP B.V. 21. Contact information For more information, please visit: http://www.nxp.com For sales office addresses, please send an email to: salesaddresses@nxp.com TDF8599_1 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 50 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 22. Tables Quick reference data . . . . . . . . . . . . . . . . . . . . .2 Ordering information . . . . . . . . . . . . . . . . . . . . .2 Pin description . . . . . . . . . . . . . . . . . . . . . . . . . .5 I2C-bus mode operation . . . . . . . . . . . . . . . . . . .8 Non-I2C-bus mode operation . . . . . . . . . . . . . . .8 Mode setting OSCIO . . . . . . . . . . . . . . . . . . . . .8 Oscillator modes . . . . . . . . . . . . . . . . . . . . . . .11 Operation mode selection with the MOD pin . .12 Overview of protection types . . . . . . . . . . . . . .15 Overview of TDF8599 protection circuits and amplifier states . . . . . . . . . . . . . . . . . . . . . . . . .17 Table 11. Available data at DIAG and CLIP pin . . . . . . . .18 Table 12. Interpretation of DC load detection bits . . . . . .20 Table 13. TDF8599 address using an external resistor . .23 Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. Table 26. Instruction byte descriptions . . . . . . . . . . . . . . 25 Frequency bit settings . . . . . . . . . . . . . . . . . . . 25 Description of data bytes . . . . . . . . . . . . . . . . . 26 Limiting values . . . . . . . . . . . . . . . . . . . . . . . . . 27 Thermal characteristics . . . . . . . . . . . . . . . . . . 27 Static characteristics . . . . . . . . . . . . . . . . . . . . 28 Switching characteristics . . . . . . . . . . . . . . . . . 31 Dynamic characteristics . . . . . . . . . . . . . . . . . 32 Filter components values . . . . . . . . . . . . . . . . 36 SnPb eutectic process (from J-STD-020C) . . . 47 Lead-free process (from J-STD-020C) . . . . . . 47 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Revision history . . . . . . . . . . . . . . . . . . . . . . . . 49 23. Figures Fig 1. Fig 2. Fig 3. Fig 4. Fig 5. Fig 6. Fig 7. Fig 8. Fig 9. Fig 10. Fig 11. Fig 12. Fig 13. Fig 14. Fig 15. Fig 16. Fig 17. Fig 18. Fig 19. Fig 20. Fig 21. Fig 22. Fig 23. Fig 24. Fig 25. Fig 26. Fig 27. Fig 28. Fig 29. TDF8599_1 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Heatsink up (top view) pin configuration TDF8599TH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Heatsink down (top view) pin configuration TDF8599TD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Mode selection. . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Oscillator frequency as function of Rosc . . . . . . . . .9 Master and slave configuration . . . . . . . . . . . . . . .9 Spread spectrum mode . . . . . . . . . . . . . . . . . . . .10 Spread spectrum operation in Master mode . . . .10 Phase lock operation . . . . . . . . . . . . . . . . . . . . . .11 AD/BD modulation switching circuit . . . . . . . . . . .12 AD modulation . . . . . . . . . . . . . . . . . . . . . . . . . . .13 BD modulation . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Master and slave operation with 12 p phase shift.14 Mono and Parallel modes . . . . . . . . . . . . . . . . . .14 DC offset protection and diagnostic output . . . . .16 Diagnostic output for short circuit conditions . . . .18 DC load detection circuit . . . . . . . . . . . . . . . . . . .19 DC load detection procedure . . . . . . . . . . . . . . . .19 DC load detection limits . . . . . . . . . . . . . . . . . . . .19 Recommended start-up sequence with DC load detection enabled. . . . . . . . . . . . . . . . . . . . . . . . .21 Start-up and shutdown timing in I2C-bus mode with DC load detection . . . . . . . . . . . . . . . . . . . . .22 Start-up and shutdown timing in non-I2C-bus mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 I2C-bus start and stop conditions. . . . . . . . . . . . .24 Data bits sent from Master microprocessor (Mmp). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 I2C-bus write . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 I2C-bus read. . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Po as a function of Vp in stereo mode with THD = 0.5 % . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Po as a function of Vp in stereo mode with THD = 10 % . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Po as a function of Vp in parallel mode with THD = 0.5 % . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Fig 30. Po as a function of Vp parallel mode with THD = 10 %. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Fig 31. THD + N as a function of output power . . . . . . . . 37 Fig 32. THD + N as a function of output power . . . . . . . . 37 Fig 33. THD + N as a function of frequency with a 2 W load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Fig 34. THD + N as a function of frequency with a 4 W load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Fig 35. Channel separation as a function of frequency with a 2 W load . . . . . . . . . . . . . . . . . . 38 Fig 36. Channel separation as a function of frequency with a 4 W load . . . . . . . . . . . . . . . . . . 38 Fig 37. CMRR as a function of frequency . . . . . . . . . . . . 39 Fig 38. Gain as a function of frequency. . . . . . . . . . . . . . 39 Fig 39. Efficiency as a function of Po . . . . . . . . . . . . . . . . 39 Fig 40. Power dissipation as a function of total output power . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Fig 41. Example application diagram for dual BTL in non-I2C-bus mode . . . . . . . . . . . . . . . . . . . . . . . . 40 Fig 42. Example application diagram for dual BTL in I2C-bus mode. . . . . . . . . . . . . . . . . . . . . . . . . . 41 Fig 43. Example application diagram for a single BTL in I2C-bus mode. . . . . . . . . . . . . . . . . . . . . . . . . . 42 Fig 44. Master-slave example application diagram; one BTL master and two BTL slaves in I2C-bus mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Fig 45. Package outline SOT851-2 (HSOP36) . . . . . . . . 44 Fig 46. Package outline SOT938-1 (HSOP36) . . . . . . . . 45 Fig 47. Temperature profiles for large and small components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 (c) NXP B.V. 2008. All rights reserved. Product data sheet Rev. 01 -- 13 November 2008 51 of 52 NXP Semiconductors TDF8599 Class-D power amplifier with load diagnostics 24. Contents 1 2 3 4 5 6 7 7.1 7.2 8 8.1 8.2 8.3 8.3.1 8.3.2 8.3.3 8.3.4 8.4 8.4.1 8.4.2 8.4.3 8.5 8.5.1 8.5.2 8.5.3 8.5.4 8.5.5 8.5.6 8.5.7 8.6 8.6.1 8.6.2 8.6.2.1 8.6.2.2 8.6.2.3 8.6.2.4 8.6.3 9 9.1 9.2 10 11 12 12.1 General description . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Quick reference data . . . . . . . . . . . . . . . . . . . . . 2 Ordering information . . . . . . . . . . . . . . . . . . . . . 2 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Pinning information . . . . . . . . . . . . . . . . . . . . . . 4 Pinning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Pin description . . . . . . . . . . . . . . . . . . . . . . . . . 5 Functional description . . . . . . . . . . . . . . . . . . . 6 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mode selection . . . . . . . . . . . . . . . . . . . . . . . . . 7 Pulse-width modulation frequency . . . . . . . . . . 8 Master and slave mode selection . . . . . . . . . . . 8 Spread spectrum mode (Master mode) . . . . . . 9 Frequency hopping (Master mode). . . . . . . . . 10 Phase lock operation (Slave mode) . . . . . . . . 10 Operation mode selection. . . . . . . . . . . . . . . . 11 Modulation mode . . . . . . . . . . . . . . . . . . . . . . 12 Phase staggering (Slave mode) . . . . . . . . . . . 13 Parallel mode . . . . . . . . . . . . . . . . . . . . . . . . . 14 Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Thermal foldback . . . . . . . . . . . . . . . . . . . . . . 15 Overtemperature protection . . . . . . . . . . . . . . 15 Overcurrent protection . . . . . . . . . . . . . . . . . . 15 Window protection . . . . . . . . . . . . . . . . . . . . . 16 DC Protection . . . . . . . . . . . . . . . . . . . . . . . . . 16 Supply voltages . . . . . . . . . . . . . . . . . . . . . . . 17 Overview of protection circuits and amplifier states . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Diagnostic output . . . . . . . . . . . . . . . . . . . . . . 18 Diagnostic table . . . . . . . . . . . . . . . . . . . . . . . 18 Load identification (I2C-bus mode only) . . . . . 19 DC load detection . . . . . . . . . . . . . . . . . . . . . . 19 Recommended start-up sequence with DC load detection enabled . . . . . . . . . . . . . . . . . . 20 AC load detection . . . . . . . . . . . . . . . . . . . . . . 21 CLIP detection . . . . . . . . . . . . . . . . . . . . . . . . 21 Start-up and shutdown sequence. . . . . . . . . . 22 I2C-bus specification . . . . . . . . . . . . . . . . . . . . 23 Instruction bytes . . . . . . . . . . . . . . . . . . . . . . . 25 Data bytes. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Limiting values. . . . . . . . . . . . . . . . . . . . . . . . . 27 Thermal characteristics. . . . . . . . . . . . . . . . . . 27 Static characteristics. . . . . . . . . . . . . . . . . . . . 28 Switching characteristics . . . . . . . . . . . . . . . . 31 13 14 14.1 14.2 14.3 14.4 14.5 14.6 14.7 15 16 17 17.1 17.2 17.3 17.4 18 19 20 20.1 20.2 20.3 20.4 21 22 23 24 Dynamic characteristics . . . . . . . . . . . . . . . . . Application information . . . . . . . . . . . . . . . . . Output power estimation (Stereo mode) . . . . Output power estimation (Parallel mode) . . . . Output current limiting . . . . . . . . . . . . . . . . . . Speaker configuration and impedance. . . . . . Heat sink requirements . . . . . . . . . . . . . . . . . Curves measured in reference design . . . . . . Typical application schematics . . . . . . . . . . . . Package outline . . . . . . . . . . . . . . . . . . . . . . . . Handling information . . . . . . . . . . . . . . . . . . . Soldering of SMD packages . . . . . . . . . . . . . . Introduction to soldering. . . . . . . . . . . . . . . . . Wave and reflow soldering . . . . . . . . . . . . . . . Wave soldering. . . . . . . . . . . . . . . . . . . . . . . . Reflow soldering. . . . . . . . . . . . . . . . . . . . . . . Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . Revision history . . . . . . . . . . . . . . . . . . . . . . . Legal information . . . . . . . . . . . . . . . . . . . . . . Data sheet status . . . . . . . . . . . . . . . . . . . . . . Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . Disclaimers. . . . . . . . . . . . . . . . . . . . . . . . . . . Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . Contact information . . . . . . . . . . . . . . . . . . . . Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 33 33 35 35 36 36 37 40 44 46 46 46 46 46 47 48 49 50 50 50 50 50 50 51 51 52 Please be aware that important notices concerning this document and the product(s) described herein, have been included in section `Legal information'. (c) NXP B.V. 2008. All rights reserved. For more information, please visit: http://www.nxp.com For sales office addresses, please send an email to: salesaddresses@nxp.com Date of release: 13 November 2008 Document identifier: TDF8599_1 |
Price & Availability of TDF8599
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |