General Power Transformer Type: EI-30 Product Description 33.0x27.0mm Max.(LxW), 33.0mm Max. Height. Custom design is available. Feature Max. Operating frequency 300kHz. Max Operating power 67.0W(300kHz) Ideally used as general power transformers in Switching regulator, EL inverter and Power Factor Correction choke RoHS Compliance 3 3 .0 M ax . 27 .0Ma x. 33 .0M ax. Adhes ve i +1.0 6. 0-0. 5 0 .8 0 . 1 Dimensions (mm) 2 0 .0 0 . 2 Schematics (Bottom) 1. For General Power Transformer. S S S 2. For PFC choke. S S S S S " S" is winding start " S" is winding start Specification (For General Transformer) Sample No. 3391-T044 Inductance (7-9) 1kHz/1V 470H 40% (m Max.) 34.0 D.C.R. (7-9) Hi-pot Winding-winding (50/60Hz) AC 500Vrms/1min. Specification (For PFC choke) Sample No. Inductance (1,2,3,4,5-6,7,8,9,10) 1kHz/1V 50H18% D.C.R. (7-9) (m Max.) 4.0 Rated Current (1,2,3,4,5-6,7,8,9,10) 1.5 A 3391-T047 Rated current: The DC current at which the inductance decreases to 90 % of it's initial value or when t=40, whichever is lower(Ta=20). Please refer to the sales offices on our website for a representative near you www.sumida.com 0.2 4-5.0 1/1 |