If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
UF4001 ... UF4007 UF4001 ... UF4007 Ultrafast Switching Si-Rectifiers - Ultraschnelle Si-Gleichrichter Version 2006-04-26 Nominal current Nennstrom O 2.6 -0.1 1A 50...1000 V DO-41 DO-204AL 0.4 g Repetitive peak reverse voltage Periodische Spitzensperrspannung Plastic case Kunststoffgehause Weight approx. Gewicht ca. 0.5 Type 62.5 5.1 -0.1 O 0.80.05 Plastic material has UL classification 94V-0 Gehausematerial UL94V-0 klassifiziert Standard packaging taped in ammo pack Standard Lieferform gegurtet in Ammo-Pack Dimensions - Mae [mm] Maximum ratings Type Typ UF4001 UF4002 UF4003 UF4004 UF4005 UF4006 UF4007 Max. average forward rectified current, R-load Dauergrenzstrom in Einwegschaltung mit R-Last Repetitive peak forward current Periodischer Spitzenstrom Peak forward surge current, 50/60 Hz half sine-wave Stostrom fur eine 50/60 Hz Sinus-Halbwelle Rating for fusing - Grenzlastintegral, t < 10 ms Junction temperature - Sperrschichttemperatur Storage temperature - Lagerungstemperatur Repetitive peak reverse voltage Periodische Spitzensperrspannung VRRM [V] 50 100 200 400 600 800 1000 TA = 50C f > 15 Hz TA = 25C TA = 25C IFAV IFRM IFSM i2t Tj TS Grenzwerte Surge peak reverse voltage Stospitzensperrspannung VRSM [V] 50 100 200 400 600 800 1000 1 A 1) 10 A 1) 30/33 A 4.5 A2s -50...+175C -50...+175C 1 Valid, if leads are kept at ambient temperature at a distance of 10 mm from case Gultig, wenn die Anschlussdrahte in 10 mm Abstand vom Gehause auf Umgebungstemperatur gehalten werden http://www.diotec.com/ (c) Diotec Semiconductor AG 1 UF4001 ... UF4007 Characteristics Type Typ UF4001 ... UF4003 UF4004 UF4005 ... UF4007 Leakage current Sperrstrom Thermal resistance junction to ambient air Warmewiderstand Sperrschicht - umgebende Luft Thermal resistance junction to leads Warmewiderstand Sperrschicht - Anschlussdraht Reverse recovery time Sperrverzugszeit trr [ns]1) < 50 < 50 < 75 Tj = 25C Tj = 100C Kennwerte Forward voltage Durchlass-Spannung VF [V] < 1.0 < 1.25 < 1.7 VR = VRRM VR = VRRM IR IR RthA RthL at / bei IF = [A] 1 1 1 < 10 A < 50 A < 45 K/W 2) < 15 K/W 120 [%] 100 10 [A] UF4001...3 1 80 UF4004 UF4005...7 60 0.1 40 10-2 20 IFAV 0 0 TA 50 100 150 [C] 1 IF 10-3 Tj = 25C VF Forward characteristics (typical values) Durchlasskennlinien (typische Werte) [V] Rated forward current versus ambient temperature ) Zul. Richtstrom in Abh. von der Umgebungstemp.1) 1 2 IF = 0.5 A through/uber IR = 1 A to/auf IR = 0.25 A Valid, if leads are kept at ambient temperature at a distance of 10 mm from case Gultig, wenn die Anschlussdrahte in 10 mm Abstand vom Gehause auf Umgebungstemperatur gehalten werden http://www.diotec.com/ (c) Diotec Semiconductor AG 2 |
Price & Availability of UF4007
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |