![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
version 2.0 06/98 ______________________________________________________________________________________________________ TFS469.doc VI TELEFILTER Specification TFS 469 - 1/4 ______________________________________________________________________________________________________ Measurement condition Ambient temperature: Input power level: Terminating impedance: 23 C 0 dBm 270 || -1pF Construction and pin connection see page 2 Stability characteristics and packing see page 3 Air reflow temperature conditions see page 4 Characteristics Remark: Reference level for the relative attenuation arel is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency is fixed on 469.99 MHz. The centre frequency f0 is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. Data ______________________________________________________________________________________________________ Insertion loss 3 dB max. 5 dB ae = amin (Reference level) ______________________________________________________________________________________________________ Nominal frequency fN 469.99 MHz ______________________________________________________________________________________________________ Centre frequency f0 469,99 MHz ______________________________________________________________________________________________________ 3 dB - bandwidth 280 kHz BW ______________________________________________________________________________________________________ Usable signal bandwidth min. fN 10 kHz ______________________________________________________________________________________________________ Relative attenuation arel fN + 910 kHz min. 52 dB min. 40 dB fN 0,7 MHz ... fN 10 MHz ______________________________________________________________________________________________________ Temperature coefficient of frequency -0,036 ppm/K2 TCf ______________________________________________________________________________________________________ Frequency inversion temperature + 25 C ______________________________________________________________________________________________________ Operating temperature range - 10C ... + 50C ______________________________________________________________________________________________________ typ. value Variation / Limitation generated: checked / approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron Technologies, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS469.doc version 2.0 06/98 ______________________________________________________________________________________________________ VI TELEFILTER Specification TFS 469 - 2/4 ______________________________________________________________________________________________________ Construction and pin connection (All dimensions in mm) 8 9 7 6 5 4 10 TFS 469 tft K6 1 2 3 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Ground Output Ground Ground Ground Ground Input 50 test circuit 1 L1 10 5 L2 C1 C2 1,2,3,4 6,7,8,9 50 test circuit 2 C1 10 5 C2 L1 L2 1,2,3,4 6,7,8,9 ______________________________________________________________________________________________________ VI TELEFILTER Vectron Technologies, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS469.doc version 2.0 06/98 ______________________________________________________________________________________________________ VI TELEFILTER Specification TFS 469 - 3/4 ______________________________________________________________________________________________________ Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (steady state) 4. Resistance to solder heat (reflow): 100g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,075 mm or 1g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 90 % to 95 % rel. humidity, 40 C, 10 days; DIN IEC 68 - 2 - 3 max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 3400 Tape (all dimensions in mm) W : Po : Do : D1 : E : F : G (min) : P2 : P1 : D1(min) : Ao : Bo : 16 0,3 4 0,1 1,5 + 0,5 1,5 + 0,5 1,75 0,1 7,5 0,1 0,75 2 0,05 8 0,1 1,5 5,3 0,1 9,7 0,1 EMBOSSED CARRIER TAPE Do Po P2 E Ao F W D1 13,4 0,1 Bo G P1 COVER TAPE W2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 16,4 +2 22,4 >= 90 C A N 13 0,25 W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ______________________________________________________________________________________________________ VI TELEFILTER Vectron Technologies, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS469.doc version 2.0 06/98 ______________________________________________________________________________________________________ VI TELEFILTER Specification TFS 469 - 4/4 ______________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron Technologies, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS469
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |