![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS 210H.doc version 1.1 07.01.2004 VI TELEFILTER Measurement condition Ambient temperature T A: Input power level: Terminating impedances at fc *): 23 C 0 dBm input: output: Filter Specification TFS 210H 1/5 1,17 k 1,06 k || -7,3 pF || -6,8 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 210H is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the frequency response of the filter in the operating temperature range. Data Insertion Loss (Reference level) Centre Frequency at ambient temperature Pass Band Relative Attenuation fc fc 475 fc fc fc fc fc fc + ......... kHz ......... ......... ......... ......... ......... ......... ......... fc 475 fc 815 fc fc fc fc fc fc 1,3 1,475 2,0 5,0 + 5,0 10,0 ae typ. value 8,5 dB tolerance / limit max. 11 dB** fc PB - 210,816 MHz fc 50 kHz 0,8 MHz arel kHz kHz MHz MHz MHz MHz MHz MHz 1,5 7 24 38 43 48 45 52 225 0,9 15 C dB dB dB dB dB dB dB dB dB s max. max. min. min. min. min. min. min. 3 10 20 30 40 45 42 40 dB dB dB dB dB dB dB dB ns 1,175 MHz 1,3 MHz 1,475 MHz 2,0 MHz 2,0 MHz 5,0 MHz Group Delay Ripple in PB Average Group Delay in PB Operating Temperature Range Storage Temperature Range Turnover temperature To Temperature Coefficient of frequency TCf*** max. 300 max. 1,3 s C C - 10 C ... + 55 - 40 C ... + 85 - - 0,036 ppm / K2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) q-values of matching inductors: q=40 ***) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz) generated: checked / approved: TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS 210H.doc version 1.1 07.01.2004 VI TELEFILTER Package Filter Specification TFS 210H 2/5 13,6Max. TFS 210H 1 2 3 4 5 6 7 8 9 10 11 12 ground ground ground ground output output rf return ground ground ground ground input input rf return S02 1 1,5 2,54 0,15 date code 1234 12 11 10 9 8 7 0,8 0,1 5 6 date code: year + week R 2003 S 2004 T 2005 ...... 50 matching network : L1 11 Input 50 Ohm C1 5 L2 Output 50 Ohm C2 SAW 1,2,3,4,6,7,8,9,10,12 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS 210H.doc version 1.1 07.01.2004 VI TELEFILTER Filter Specification TFS 210H 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 1700 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) W Po Do E F : : : : : 24 4 0,3 0,1 Do Po EMBOSSED CARRIER TAPE P2 1,5 + 0,1 1,75 0,1 11,5 0,1 0,60 2 12 1,5 7,1 13,9 21,5 0,1 0,1 0,2 0,2 0,1 P1 Ct Bo Ao D1 E G (min) : P2 : P1 : D1(min) : Ao Bo Ct : : : F W G COVER TAPE W2 Reel (all dimensions in mm): A : 330 24,40 +2,0 30,4 60 13 0,5/-0.2 A C N W1 : W2 (max) : N (min) C : : W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS 210H.doc version 1.1 07.01.2004 VI TELEFILTER Air reflow temperature conditions Filter Specification TFS 210H 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS 210H.doc version 1.1 07.01.2004 VI TELEFILTER Filter Specification TFS 210H 5/5 History Version 1.0 1.1 Reason of Changes generate specification according to customer requirements terminating impedance and typical values added Name Pfeiffer Pfeiffer Date 10.12.2003 07.01.2004 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS210H
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |