 TOTAL POWER INT'L
40W Single Output Switching Power Supply
Features :
Universal AC input / Full range Protections:Short circuit/Over load Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 36KHz 2 years warranty
S-40
series
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT
S-40-5 S-40-12 S-40-15 S-40-24
5V 8A 0 ~ 8A 40W
12V 3.5A 0 ~ 3.5A
42W 100mVp-p
15V 2.8A 0 ~ 2.8A 42W 100mVp-p
13.5 ~ 16.5V
1.0%
0.5%
0.5%
24V 1.8A 0 ~ 1.8A 43W 100mVp-p
21.6 ~ 26.4V
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.) Note.2 75mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5%
10.8 ~ 13.2V 1.0%
0.5%
0.5%
LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER LOAD
PROTECTION
1.0% 300ms, 50ms, 60ms/230VAC
800ms, 50ms, 15ms/115VAC at full load
85 ~ 264VAC 47 ~ 63Hz 72%/115VAC
120 ~ 370VDC 76%/115VAC 76%/115VAC 78%/115VAC
1.2A/115VAC 0.6A/230VAC COLD START 30A/115VAC 60A/230VAC <1mA / 240VAC 105 ~ 150% rated output power
5.75 ~ 6.75V
OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMC (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS
NOTE
Protection type : Hiccup mode, recovers automatically after fault condition is removed 13.8 ~ 16.2V 17.25 ~ 20.25 Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60
-20 ~ +85
27.6 ~ 32.4V
(Refer to output load derating curve)
, 10 ~ 95% RH
20 ~ 90% RH non-condensing
0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL1950, TUV EN60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A
DIMENSION PACKING
314.1K hrs min. MIL-HDBK-217F (25 129*98*38mm (L*W*H)
0.45Kg; 30pcs/13.5Kg/0.86CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
40W Single Output Switching Power Supply
Mechanical Specification
122.5
S-40
Case No. 903
series
Unit:mm
1
9 .5
2 3
8.2
5
3 .5
4.5
73.5 129
6.5
120
9 .5
9
1 8 .5
3 .5
9 3 7 .5
3 -M
3
32
77
Terminal Pin. No Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 Assignment DC OUTPUT -V DC OUTPUT +V
Output Derating
Static Characteristics (24V)
Ta=25
18
9 7 .7 5
33
8 5 .5
4
2-
M
3
31
3 .5
7
3 .5
32
100
350 300 250 200 150 100 50
80
OUTPUT VOLTAGE (V)
28 24 20 16 12 8
60
40
20
-10 -10
0
10
20
30
40
50 45
60 55
(VERTICAL) (HORIZONTAL)
60
80
100
120
140
160
180
200
220
240
260
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (V) 60Hz
OUTPUT RIPPLE (mVp-p)
LOAD (%)


▲Up To Search▲   

 
Price & Availability of S-40-5

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X