![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
PRELIMINARY 45 Features * Autoranging 115/230 Vac input * Two, low profile, IFE International AC Front End 500 Watts chassis mount versions * 500 Watts * Meets EN55022-B * Meets EN61000-3-2 harmonic current limits * Rugged coldplate construction Product Overview The International Front End (IFE) is an enclosed chassis mount, AC Front End which may be used with VIPAC Arrays, MegaModules or any of Vicor's 300V input DC-DC converters to create a complete, low profile, high density, AC-DC power supply. The IFE operates from worldwide AC mains and includes autoranging line rectification, integral EMI filtering, hold-up capacitors, harmonic current attenuation and transient suppression. The IFE incorporates Vicor's passive harmonic current attenuation technology and FARM modules to deliver 500 Watts while meeting EN61000-3-2 limits. All internal heat producing components are coupled to the chassis for optimal thermal transfer. Two rugged, coldplate packages are available -- one with threaded inserts and the other with thru hole flanges -- which may be mounted directly to a cabinet wall or an existing heat sink for high temperature operation. The International Front Ends (IFE) provide an off-the-shelf solution for many custom and standard power supply requirements where space constraints and time to market are critical. Absolute Maximum Ratings Parameter L to N voltage +Out to -Out voltage B OK to -Out voltage EN to -Out voltage Mounting torque Operating temperature Storage temperature Rating 264 400 16 16 15 (1.7) 95 125 Unit Vrms Vdc Vdc Vdc in-lbs (N-m) C C 6 M4 x 0.7 Chassis/BP Ambient Notes Continuous Part Numbering IFE Product 5 Type 5 = 500 W C 0 Termination 0 = Connector 2 Product Grade C = -20C to 95C (BP) T = -40C to 95C (BP) Base Style 1 = External flange 2 = Internal threaded Options Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 1 of 7 Set your site on VICOR at www.vicorpower.com PRELIMINARY ELECTRICAL CHARACTERISTICS Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. INPUT SPECIFICATIONS Parameter Operating input voltage Operating input voltage AC line frequency Power factor Efficiency Min 90 180 47 0.68 94 0.72 96 % Typ 115 230 Max 132 264 63 Unit Vac Vac Hz 230 Vac input Full load Notes Autoranging (doubler mode) Autoranging (bridge mode) Input current 115 Vac input 230 Vac input Inrush current 115 Vac input 230 Vac input 15 30 A pk A pk 9 4.5 9.5 4.75 Arms Arms 500 W output 500 W output OUTPUT SPECIFICATIONS Parameter Output voltage Output power Hold-up time 90 Vac Input 115 Vac Input 90 Vac Input 115 Vac Input Power fail warning time Power fail warning time 23 58 93 229 6.5 25 ms ms ms ms ms ms 500 W output 500 W output 500 W output with 2460 F external hold-up capacitor 500 W output with 2460 F external hold-up capacitor 115 Vac input, 500 W output 115 Vac input, 500 W output with 2460 F external hold-up capacitor Min Typ 250 500 Max 375 550 Unit Vdc Watts 90-132 / 180-264 Vac input Notes SAFETY SPECIFICATIONS Parameter Safety approvals (pending) Isolation voltage (in to out) Isolation voltage (I/O to chassis) Leakage current 2121 TBD Min Typ cTUVus, CE Marked none Vdc 264 Vac input, 50Hz Max Unit Notes CE marked according to the Low Voltage Directive 72/23/EEC amendment 93/68/EEC Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 2 of 7 Set your site on VICOR at www.vicorpower.com PRELIMINARY ELECTRICAL CHARACTERISTICS, continued ELECTROMAGNETIC COMPATIBILITY Parameter Harmonic currents Voltage fluctuations and flicker Electrical fast transient/burst Input surge withstand RF line conducted immunity Voltage dips and interrupts Conducted emissions Min Typ EN61000-3-2 EN61000-3-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-11 EN55022, Level B Max Unit Notes See Fig. 1 Test in process Test in process Test in process Test in process Test in process See Fig. 2 CONTROL SPECIFICATIONS Parameter Enable Low state current Low state resistance High state voltage Enable threshold Disable threshold Bus OK Low state current Low state resistance High state voltage B OK true threshold B OK false threshold 235 200 15 240 205 245 210 50 15 mA ohms Vdc Vdc Vdc Bus normal To negative output 150k internal pull up to 16 Vdc Output bus voltage Output bus voltage 235 185 15 240 50 15 mA ohms Vdc Vdc Vdc Bus normal To negative output 150k internal pull up to 16 Vdc Output bus voltage Output bus voltage Min Typ Max Unit Notes GENERAL SPECIFICATIONS Parameter MTBF Coldplate and Cover material Weight Package size Internal threaded (IFE5xx2) Thru hole flange (IFE5xx1) Mounting Internal Threaded Flange clearance hole Storage Temperature C, T-Grade Operating Temperature C-Grade T-Grade -20 -40 95 95 C C -40 125 C M4 x 0.7 M4 or #8 6 locations max. 12mm max penetration, torque 15 in. lbs. (1.7Nm) 4 locations Min Typ Max Unit Notes aluminum 1.13 (2.5) L xW x H 240 x 100 x 26.25 (9.45" x 3.93" x 1.12")mm (in) 260 x 100 x 26.25 (10.24" x 3.93" x 1.12")mm (in) kg (lbs.) Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 3 of 7 Set your site on VICOR at www.vicorpower.com PRELIMINARY PERFORMANCE CHARACTERISTICS 10.00 1.00 Current (A) Odd Harmonic Limits * Even Harmonic Limits Measured Values 0.10 0.01 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Harmonic Number Figure 1 -- Measured harmonic current at 230 Vac, 50 Hz, 550 W vs. EN spec limits *Measured values of even harmonics are below 0.01 A Figure 2--Conducted line noise, EN55022-B Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 4 of 7 Set your site on VICOR at www.vicorpower.com PRELIMINARY Connection Diagram IFE Output Connector Pin# 1 2 LI L2/N PE 4 8 7 6 5 Function ST SR -VOUT -VOUT B OK EN +VOUT +VOUT +In PC (Gate In) Vicor 300Vin DC-DC Converter +In PC (Gate In) Vicor 300Vin DC-DC PR (Gate Out) Converter -In 3 4 5 6 7 8 IFE 3 2 1 PR (Gate Out) -In Optional External Hold-Up Capacitor Figure 3--Connection diagram using IFE with Vicor 300 Vin DC-DC converter(s) J2 Input Connector Pin# 1 2 Function Enable SR J2 1 2 IFE Output Connector Pin# 1 2 3 LI L2/N PE 4 8 7 6 5 J1 Input Connector Pin# 1-4 5-7 8 9 Function -VIN +VIN NC/PR Bus Function ST SR -VOUT -VOUT B OK EN +VOUT +VOUT J1 10 20 9 8 7 6 5 4 19 18 17 16 15 14 13 12 11 VIPAC Array 4 5 6 7 8 IFE 3 2 1 PE - Remote 10 Enable 11-13 -VIN 14-17 18 19 +5V +VIN NC/PR Bus PE + Remote Enable 3 2 1 20 Optional External Hold-Up Capacitor - Figure 4--Connection diagram using IFE with ViPAC Array Mating Connector Mfg. P/N Wickman Series 194 0.25'' insulated receptacle 25056 24796 25073 24795 24796 24828 27866 27867 27881 AMP P/N 794657-8 AMP P/N1-106529-2 Function IFE Input fuse IFE Input Connector IFE Output Connector Description 5 x 20 mm, 10A fast acting 0.25'' male Faston 8 position AMP Duac Housing Pins Kit (Pins & Housing) 20 position AMP Duac Housing Pins Kit (Pins & Housing) Housing Pins Kit (Pins & Housing) Vicor P/N VIPAC Array Input Connector J1 AMP P/N 2-794657-0 AMP P/N 1-106529-0 VIPAC Array Input Connector J2 Molex 39-01-2025 Molex 39-00-0039 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 5 of 7 Set your site on VICOR at www.vicorpower.com PRELIMINARY MECHANICAL DRAWINGS OUTLINE DRAWING IFE5xx1 260 0.76 10.236 0.030 1000.76 3.9370.030 28.25 0.76 1.112 0.030 INPUT OUTPUT o 5.41 THRU 4 PL 0.213 90 3.543 2 PL 5 0.38 0.197 0.015 2 PL 5 0.38 0.197 0.015 2 PL 250 9.843 2 PL OUTLINE DRAWING IFE5xx2 240 0.76 9.449 0.030 100 0.76 3.937 0.030 28.25 0.76 1.112 0.030 INPUT OUTPUT M4 X 0.7 MOUNTING 6 PL MARKED 'B' 'B' 'B' 'B' 86 3.386 3 PL 'B' 'B' 'B' 7 0.38 0.276 0.015 3 PL 14.5 0.38 0.571 0.015 2 PL 139 5.472 2 PL 211 8.307 2 PL Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 6 of 7 Set your site on VICOR at www.vicorpower.com Vicor's comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor's Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. 45 Component Solutions for Your Power System Vicor Corporation 25 Frontage Road Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 Email Vicor Express: vicorexp@vicr.com Technical Support: apps@vicr.com Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End P/N 27902 Rev.1.1 04/04/10M Set your site on VICOR at www.vicorpower.com |
Price & Availability of IFE5T02
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |