MITSUBISHI GATE TURN-OFF THYRISTORS FG3000GX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE FG3000GX-90DA OUTLINE DRAWING Dimensions in mm GATE (WHITE) 494 8 AUXILIARY CATHODE CONNECTOR (RED) 3.5 DEPTH 2.2 0.2 CATHODE TYPENAME q ITQRM Repetitive controllable on-state current ...........3000A q IT(AV) Average on-state current .....................1000A q VDRM Repetitive peak off state voltage ...................4500V q Anode short type 26 0.5 0.4 MIN 0.4 MIN 75 0.2 75 0.2 108 MAX ANODE 3.5 DEPTH 2.2 0.2 APPLICATION Inverters, D.C. choppers, Induction heaters, D.C. to D.C. converters. MAXIMUM RATINGS Symbol VRRM VRSM VR(DC) VDRM VDSM VD(DC) VLTDS Parameter Repetitive peak reverse voltage Non-repetitive peak reverse voltage DC reverse voltage Repetitive peak off-state voltage* Non-repetitive peak off-state voltage* DC off-state voltage* Long term DC stability voltage* Parameter Repetitive controllable on-state current RMS on-state current Average on-state current Surge (non-repetitive) on-state current Current-squared, time integration Critical rate of rise of on-state current Peak forward gate voltage Peak reverse gate voltage Peak forward gate current Peak gate reverse current Peak forward gate power dissipation Peak reverse gate power dissipation Average forward gate power dissipation Average reverse gate power dissipation Junction temperature Storage temperature Mounting force required Weight Voltage class 90DA 17 17 17 4500 4500 3600 3000 Conditions VDM = 4500V, Tj = 125C, CS = 3.0F, LS = 0.25H f = 60Hz, sine wave = 180, Tf = 73C One half cycle at 60Hz One cycle at 60Hz VD = 3400V, IGM = 25A, Tj = 125C Ratings 3000 1570 1000 20 1.6 x 106 500 10 17 130 900 520 33 130 300 -40 ~ +125 -40 ~ +150 30 ~ 40 1220 Unit V V V V V V V Unit A A A kA A2s A/s V V A A W kW W W C C kN g Aug.1998 * Symbol ITQRM IT(RMS) IT(AV) ITSM I2t diT/dt VFGM VRGM IFGM IRGM PFGM PRGM PFG(AV) PRG(AV) Tj Tstg -- -- : VGK = -2V Recommended value 33 Standard value MITSUBISHI GATE TURN-OFF THYRISTORS FG3000GX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE ELECTRICAL CHARACTERISTICS Symbol VTM IRRM IDRM IRG dv/dt tgt tgq IGQM VGT IGT Rth(j-f) Parameter On-state voltage Repetitive peak reverse current Repetitive peak off-state current Reverse gate current Critical rate of rise of off-state voltage Turn-on time Turn-off time Peak gate turn-off current Gate trigger voltage Gate trigger current Thermal resistance Test conditions Tj = 125C, ITM = 3000A, Instantaneous measurment Tj = 125C, VRRM Applied Tj = 125C, VDRM Applied, VGK = -2V Tj = 125C, VRG = 17V Tj = 125C, VD = 2250V, VGK = -2V Tj = 125C, ITM = 3000A, IGM = 25A, VD = 3400V Tj = 125C, ITM = 3000A, VDM = 4500V, diGQ/dt = -40A/s VRG = 17V, CS = 3.0F, LS = 0.25H DC METHOD : VD = 24V, RL = 0.1, Tj = 25C Junction to fin Min -- -- -- -- 1000 -- -- -- -- -- -- Limits Typ -- -- -- -- -- -- -- 720 -- -- -- Max 4.0 10 100 10 -- 8 30 -- 1.5 2500 0.013 Unit V mA mA mA V/s s s A V mA C/W PERFORMANCE CURVES SURGE ON-STATE CURRENT (kA) ON-STATE CURRENT (A) MAXIMUM ON-STATE CHARACTERISTIC 104 7 Tj = 125C 5 4 3 2 103 7 5 4 3 2 102 0 1.0 2.0 3.0 4.0 5.0 6.0 RATED SURGE ON-STATE CURRENT 25 20 15 10 5 0 100 2 3 4 5 7 101 2 3 4 5 7 102 ON-STATE VOLTAGE (V) CONDUCTION TIME (CYCLES AT 60Hz) MAXIMUM THERMAL IMPEDANCE CHARACTERISTIC (JUNCTION TO FIN) 100 2 3 5 7101 0.025 THERMAL IMPEDANCE (C/W) GATE CHARACTERISTICS 103 7 5 3 2 7 5 3 2 7 5 3 2 GATE VOLTAGE (V) 102 VFGM = 10V VGT = 1.5V PFG(AV) = 130W PFGM = 520W 0.020 0.015 101 0.010 100 7 5 Tj = 25C 3 IGT = 2.5A 2 0.005 0 10-3 2 3 5 710-2 2 3 5 710-1 2 3 5 7 100 TIME (s) IFGM = 130A 10-1 10-1 2 3 5 7 100 2 3 5 7 101 2 3 5 7 102 2 3 5 7 103 GATE CURRENT (mA) Aug.1998 MITSUBISHI GATE TURN-OFF THYRISTORS FG3000GX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE ON-STATE POWER DISSIPATION (W) MAXIMUM ON-STATE POWER DISSIPATION CHARACTERISTICS (SINGLE-PHASE HALF WAVE) 4000 3500 3000 ALLOWABLE FIN TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE HALF WAVE) 140 130 FIN TEMPERATURE (C) 90 60 180 120 120 110 100 90 80 70 60 50 = 30 60 360 RESISTIVE, INDUCTIVE LOAD 360 RESISTIVE, 2500 INDUCTIVE LOAD = 30 2000 1500 1000 500 0 0 200 400 600 800 1000 90 120 180 40 0 200 400 600 800 1000 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) ON-STATE POWER DISSIPATION (W) MAXIMUM ON-STATE POWER DISSIPATION CHARACTERISTICS (RECTANGULAR WAVE) 5000 DC 270 ALLOWABLE FIN TEMPERATURE VS. AVERAGE ON-STATE CURRENT (RECTANGULAR WAVE) 130 120 4000 120 90 60 = 30 180 FIN TEMPERATURE (C) 360 RESISTIVE, INDUCTIVE LOAD 110 100 90 80 70 60 50 0 = 30 60 3000 2000 360 RESISTIVE, INDUCTIVE LOAD 1000 120 270 90 180 DC 0 0 200 400 600 800 1000 1200 1400 1600 200 400 600 800 1000 1200 1400 1600 AVERAGE ON-STATE CURRENT (A) AVERAGE ON-STATE CURRENT (A) GATE TRIGGER CURRENT (A), GATE TRIGGER VOLTAGE (V) TURN ON TIME tgt, TURN ON DELAY TIME td (s) GATE TRIGGER CURRENT, GATE TRIGGER VOLTAGE VS. JUNCTION TEMPERATURE (MAXIMUM) 10 9 8 7 6 5 4 3 2 1 0 -40 0 40 80 120 160 VGT IGT VD = 24V RL = 0.1 DC METHOD TURN ON TIME, TURN ON DELAY TIME VS. TURN ON GATE CURRENT (TYPICAL) 10 IT = 3000A VD = 3400V diT/dt = 500A /s diG/dt = 20A /s Tj = 125C 8 6 tgt 4 2 td 0 0 10 20 30 40 50 60 JUNCTION TEMPERATURE (C) TURN ON GATE CURRENT (A) Aug.1998 MITSUBISHI GATE TURN-OFF THYRISTORS FG3000GX-90DA HIGH POWER INVERTER USE PRESS PACK TYPE TURN OFF TIME tgq CTURN OFF STORAGE TIME ts (s) TURN OFF TIME tgq, TURN OFF STORAGE TIME ts (s) TURN OFF TIME, TURN OFF STORAGE TIME VS. TURN OFF CURRENT (TYPICAL) 50 VD = 3400V VDM = 4500V diGQ/dt = -40A/s 40 VRG = 17V CS = 3.0F LS = 0.25H 30 Tj = 125C TURN OFF TIME, TURN OFF STORAGE TIME VS. RATE OF RISE OF TURN OFF GATE CURRENT (TYPICAL) 50 40 tgq 30 ts tgq 20 ts 20 VD = 3400V VDM = 4500V IT = 3000A 10 VRG = 17V CS = 3.0F LS = 0.25H Tj = 125C 10 0 0 500 1000 1500 2000 2500 3000 3500 TURN OFF CURRENT (A) 0 10 20 30 40 50 60 RATE OF RISE OF TURN OFF GATE CURRENT (A/S) TURN OFF GATE CURRENT VS. TURN OFF CURRENT (TYPICAL) 800 TURN OFF GATE CURRENT (A) TURN OFF GATE CURRENT (A) 700 600 500 400 300 200 100 0 0 VD = 3400V VDM = 4500V diGQ/dt = -40A/s VRG = 17V CS = 3.0F LS = 0.25H Tj = 125C TURN OFF GATE CURRENT VS. RATE OF RISE OF GATE CURRENT (TYPICAL) 1200 1100 1000 900 800 700 600 500 400 300 200 10 20 30 40 VD = 3400V VDM = 4500V IT = 3000A VRG = 17V CS = 3.0F LS = 0.25H Tj = 125C 500 1000 1500 2000 2500 3000 3500 TURN OFF CURRENT (A) 50 60 RATE OF RISE OF TURN OFF GATE CURRENT (A/S) TURN ON SWITCHING ENERGY (MAXIMUM) 8 SWITCHING ENERGY Eon (J/P) SWITCHING ENERGY Eoff (J/P) VD = 2800V 7 IGM = 25A diG/dt = 20A/s CS = 3.0F 6 RS = 5 Tj = 125C TURN OFF SWITCHING ENERGY (MAXIMUM) 12 11 10 9 8 7 6 5 4 3 2 0 VD = 2800V VDM = 4500V diGQ/dt = -40A/s VRG = 17V CS = 3.0F LS = 0.25H Tj = 125C 5 4 3 2 diT/dt = 500A /s 300A/s 100A/s 1 0 0 500 1000 1500 2000 2500 3000 3500 4000 TURN ON CURRENT (A) 500 1000 1500 2000 2500 3000 3500 4000 TURN OFF CURRENT (A) Aug.1998 |
Price & Availability of FG3000GX-90DA
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |