Part Number Hot Search : 
CR20F 2SK1035 TDA9950 IL34C86N 00KTG10 M5R18RLJ 79D05 TSM230
Product Description
Full Text Search
 

To Download SCAS168 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 74ACT11352 DUAL 4-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
SCAS168 - DECEMBER 1991 - REVISED APRIL 1993
* * * * * * * * *
Inputs Are TTL-Voltage Compatible Permit Multiplexing From N Lines to 1 Line Perform Parallel-to-Serial Conversion Strobe Line Provided for Cascading (N Lines to N Lines) Flow-Through Architecture Optimizes PCB Layout Center-Pin VCC and GND Pin Configurations Minimize High-Speed Switching Noise EPIC TM (Enhanced-Performance Implanted CMOS) 1-m Process 500-mA Typical Latch-Up Immunity at 125C Package Options Include Plastic Small-Outline Packages, and Standard Plastic 300-mil DIPs
D OR N PACKAGE (TOP VIEW)
A B 1Y GND 2Y 1OE 2OE 2C3
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10 9
1C0 1C1 1C2 1C3 VCC 2C0 2C1 2C2
description
Each of these data selectors/multiplexers contains inverters and drivers to supply full binary-decoding data selection to the AND-OR gates. Separate strobe output-enable (OE) inputs are provided for each of the two four-line sections. The 74ACT11352 is characterized for operation from - 40C to 85C.
FUNCTION TABLE (each multiplexer) SELECT INPUTS B X L L L L H H H H A X L L H H L L H H C0 X L H X X X X X X DATA INPUTS C1 X X X L H X X X X C2 X X X X X L H X X C3 X X X X X X X L H STROBE OE H L L L L L L L L OUTPUT Y H H L H L H L H L
EPIC is a trademark of Texas Instruments Incorporated.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
Copyright (c) 1993, Texas Instruments Incorporated
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
1
74ACT11352 DUAL 4-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
SCAS168 - DECEMBER 1991 - REVISED APRIL 1993
logic symbol
A B 1 2 0 1 G
0 3
1OE 1C0 1C1 1C2 1C3 2OE 2C0 2C1 2C2 2C3
6 16 15 14 13 7 11 10 9 8
EN 0 1 2 3
MUX 3
1Y
5
2Y
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
2
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
74ACT11352 DUAL 4-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
SCAS168 - DECEMBER 1991 - REVISED APRIL 1993
logic diagram (positive logic)
1OE 6
1C0
16
1C1 Data 1 1C2
15 3 14 1Y
1C3
13
B Select A
2
1
2C0
11
2C1 Data 2 2C2
10 5
9
2Y
2C3
8
2OE
7
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA Continuous current through VCC or GND pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mA Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65C to 150C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
3
74ACT11352 DUAL 4-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
SCAS168 - DECEMBER 1991 - REVISED APRIL 1993
recommended operating conditions (see Note 2)
MIN VCC VIH VIL VI VO IOH IOL t/v Supply voltage High-level input voltage Low-level input voltage Input voltage Output voltage High-level output current Low-level output current Input transition rise or fall rate 0 -40 0 0 4.5 2 0.8 VCC VCC -24 24 10 85 NOM 5 MAX 5.5 UNIT V V V V V mA mA ns/V C
TA Operating free-air temperature NOTE 2: Unused or floating inputs must be held high or low.
electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER IOH = - 50 A VOH IOH = - 24 mA IOH = - 75 mA IOL = 50 A VOL IOL = 24 mA IOL = 75 mA VI = VCC or GND VI = VCC or GND, One input at 3.4 V, Other inputs at VCC or GND IO = 0 TEST CONDITIONS VCC 4.5 V 5.5 V 4.5 V 5.5 V 5.5 V 4.5 V 5.5 V 4.5 V 5.5 V 5.5 V 5.5 V 5.5 V 5.5 V 0.1 8 0.9 0.1 0.1 0.36 0.36 MIN 4.4 5.4 3.94 4.94 TA = 25C TYP MAX MIN 4.4 5.4 3.8 4.8 3.85 0.1 0.1 0.44 0.44 1.65 1 80 1 A A mA pF V V MAX UNIT
II ICC ICC
Ci VI = VCC or GND 5V 3.5 Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
switching characteristics over recommended operating free-air temperature range, VCC = 5 V 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER tPLH tPHL tPLH tPHL tPLH tPHL FROM (INPUT) A or B Any C OE TO (OUTPUT) Y Y Y MIN 2 2.9 2.1 3.3 2 2.5 TA = 25C TYP MAX 5.3 6.7 5 6.3 4.2 5.5 7.8 9.3 7.2 7.8 5.5 7.6 MIN 2 2.9 2.1 3.3 2 2.5 MAX 8.6 10.7 8.2 8.9 6 8.3 UNIT ns ns ns
4
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
74ACT11352 DUAL 4-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
SCAS168 - DECEMBER 1991 - REVISED APRIL 1993
operating characteristics, VCC = 5 V, TA = 25C
PARAMETER Cpd Power dissipation capacitance TEST CONDITIONS CL = 50 pF, f = 1 MHz TYP 30 UNIT pF
PARAMETER MEASUREMENT INFORMATION
From Output Under Test CL = 50 pF (see Note A) 500
LOAD CIRCUIT Input (see Note B) tPHL 3V 1.5 V 1.5 V 0 tPLH VOH 50% VCC VOL
Output
50% VCC VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES
NOTES: A. CL includes probe and jig capacitance. B. Input pulses are supplied by generators having the following characteristics: PRR 10 MHz, ZO = 50 , tr = 3 ns, tf = 3 ns. C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303
* DALLAS, TEXAS 75265
5
IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL APPLICATIONS"). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER'S RISK. In order to minimize risks associated with the customer's applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI's publication of information regarding any third party's products or services does not constitute TI's approval, warranty or endorsement thereof.
Copyright (c) 1998, Texas Instruments Incorporated


▲Up To Search▲   

 
Price & Availability of SCAS168

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .