![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS1220B.doc version 1.3 18.08.2003 VI TELEFILTER 1. Measurement condition 23 0 C dBm Filter Specification TFS 1220B 1/6 Ambient temperature: Input power level: Terminating impedances* for input: 200 for input: 200 2. Remark: Characteristics Reference level for the relative attenuation arel of the TFS 1220B is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 1220,0 MHz without tolerance. The temperature coefficient of frequency Tcf is valid both for the frequency fc and the frequency response of the filter in the operating temperature rang. Data Insertion loss (Reference level) Nominal frequency Centre frequency 1,5 dB Bandwidth Pass band ripple Relative attenuation fC .... fC 4,0 MHz arel ae = amin fN fc typ. value 3,50 1220,0 19,0 1,0 58 54 55 54 55 57 57 58 MHz dB dB dB dB dB dB dB dB 56 MHz MHz dB dB tolerance/limit max. 5,8 dB MHz max. 1220,0 1220,0 2,0 MHz min. 8,0 max. 1,5 max. 1,5 min. min. min. min. min. min. min. min. dB 40,2 44,2 42,0 44,2 40,2 44,2 44,2 44,2 min. MHz dB dB dB dB dB dB dB dB dB dB 44,2 BW MHz fC - 36,0 MHz fC - 44,0 MHz fC - 72,0 MHz fC - 88,0 fC - 68,0 MHz .. . fC - 76,0 MHz fC - 76,0 MHz .... fC - 85,0 MHz fC - 85,0 MHz .... fC - 91,0 MHz fC - 91,0 MHz .... fC - 720,0 MHz fC + 70,0 MHz .... fC + 780,0 dB Group delay ripple GD** fC - 4,0 MHz ... fC + 4,0 MHz 15 ns -32 ppm/K - 40 C ... + 85 C - 30 C ... + 80 C Temperature coefficient of frequency ( Tcf ) Operating temperature range Storage temperature range *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) Aperture 500 KHz Generated: Checked / approved: TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS1220B.doc version 1.3 18.08.2003 VI TELEFILTER Filter Specification TFS 1220B 2/6 3. Remark: Characteristics Reference level for the relative attenuation arel of the TFS 1220B is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 1220,0 MHz without tolerance. The temperature coefficient of frequency Tcf is valid both for the frequency fc and the frequency response of the filter in the operating temperature rang. Data Insertion loss (Reference level) Nominal frequency Centre frequency 3 dB Bandwidth Pass band ripple Relative attenuation fC - 10,0 MHz .. . fC + 9,0 arel MHz ae = amin fN fc typ. value 3,50 1220,0 25,0 1,5 58 54 55 54 55 57 57 58 MHz dB dB dB dB dB dB dB dB 56 MHz MHz dB dB tolerance/limit max. 5,8 dB MHz MHz MHz dB dB dB dB dB dB dB dB dB dB 46,0 max. 1220,0 1220,0 min. 19,0 max. 3,0 max. 3,0 min. min. min. min. min. min. min. min. dB 40,0 46,0 44,0 46,0 42,0 46,0 46,0 46,0 min. BW MHz fC - 36,0 MHz fC - 44,0 MHz fC - 72,0 MHz fC - 88,0 fC - 68,0 MHz .. . fC - 76,0 MHz fC - 76,0 MHz .... fC - 85,0 MHz fC - 85,0 MHz .... fC - 91,0 MHz fC - 91,0 MHz .... fC - 720,0 MHz fC + 70,0 MHz .... fC + 780,0 dB Group delay ripple GD** fC - 10,0 MHz ... fC + 9,0 MHz 40 -32 ppm/K ns - - Temperature coefficient of frequency ( Tcf ) Operating temperature range Storage temperature range +20 C ... + 70 C - 30 C ... + 80 C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) Aperture 500 KHz TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS1220B.doc version 1.3 18.08.2003 VI TELEFILTER Filter Specification TFS 1220B 3/6 Construction, pin configuration and 50 - matching network (All dimensions in mm) 7 5 1,78 1220B R34 1 Date code SQ 3,81 + 0,2 / -0,1 1,78 0,6 3 0,1 1,2 Max. 2,54 Pin 1 Pin 2 Pin 3 Pin 4 Input Input Ground Package Ground Pin 5 Pin 6 Pin 7 Pin 8 Output Output Ground Package ground Date code: N P R ... Year + week 2001 2002 2003 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS1220B.doc version 1.3 18.08.2003 VI TELEFILTER Stability Characteristics Filter Specification TFS 1220B 4/6 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 4 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) W Po Do : : : 12 4 1,5 0,3 0,1 + 0,1 EMBOSSED CARRIER TAPE Do Po P2 E : F : G (min) : P2 : P1 : D1(min) : Ao : Bo CT : : 1,75 0,1 5,5 0,05 0,75 2 0,05 8 0,1 1,5 4,3 0,1 4,3 9,5 0,1 0,1 E Ao F W D1 CT Bo G P1 COVER TAPE W2 Reel (all dimensions in mm): A W1 : : 330 12,4 + 2,0 18,4 50 13 +0,5/ -0,2 A C N W2 (max) : N (min) C : : W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS1220B.doc version 1.3 18.08.2003 VI TELEFILTER Filter Specification TFS 1220B 5/6 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS1220B.doc version 1.3 18.08.2003 VI TELEFILTER Filter Specification TFS 1220B 6/6 History Version 1.0 1.1 1.2 1.3 Reason of Changes - Generation of development specification according to customer specification - Change of stamp from TFS1220 to TFS1220B - Filter specification, add of typ. values - Add of second specification data sheet Name Dr. Sabah Dr. Sabah Dr. Sabah Dr. Sabah Date 05.11.2002 10.12.2002 04.08.2003 18.08.2003 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS1220B
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |