Current and Voltage Controls Current Transformer, 3-Phase Types MP 3005, MP 3020, MP 3100, MP 3500 * 4 types of input: 0.5 5A 2 - 20 A 10 - 100 A 50 - 500 A * For use in connection with control relays types e.g. S 178, SM 115 Product Description 3-phase current transformers for 5, 20, 100 or 500 AAC. Output voltage (0.4 - 4 Vp) is proportional to measured current. Ordering Key Type Input current MP 3005 Type Selection Input current 5A 20 A 100 A 500 A Type no. MP 3005 MP 3020 MP 3100 MP 3500 Input Specifications MP 3005 Current range Max. current (continuously) Rated insulation voltage Input-output Overvoltage category Pollution degree Dielectric strength Dielectric voltage Rated impulse withstand volt. Power consumption 0.5 - 5 AAC 20 AAC 1000 VACrms IV (IEC 60664) 3 (IEC 60664) 6 kVACrms 12 kV (1.2/50 s) < 300 mW @ 5 A MP 3020 2 - 20 AAC 50 AAC 1000 VACrms IV (IEC 60664) 3 (IEC 60664) 6 kVACrms 12 kV (1.2/50 s) < 300 mW @ 20 A MP 3100 10 - 100 AAC 150 AAC 1000 VACrms IV (IEC 60664) 3 (IEC 60664) 6 kVACrms 12 kV (1.2/50 s) < 2 W @ 100 A MP 3500 50 - 500 AAC 500 AAC 1000 VACrms IV (IEC 60664) 3 (IEC 60664) 6 kVACrms 12 kV (1.2/50 s) < 21 W @ 500 A Output Specifications MP 3005 Output voltage (in connection with SM 115) Rated insulation voltage (cable) MP 3020 MP 3100 MP 3500 0.4 - 4 Vp 250 VACrms 0.4 - 4 Vp 250 VACrms 0.4 - 4 Vp 250 VACrms 0.4 - 4 Vp 250 VACrms Specifications are subject to change without notice (28.10.99) 1 MP 3005, MP 3020, MP 3100, MP 3500 General Specifications MP 3005 Ambient temperature - 20 to + 60C (- 4 to + 140F) MP 3020 - 20 to + 60C (- 4 to + 140F) MP 3100 - 20 to + 60C (- 4 to + 140F) MP 3500 - 20 to + 40C (- 4 to + 104F) (max. amb. temp for < 200 A is + 60C (+140F) 2m 750 g ABS UL Connection cable Weight Material Approvals 2m 200 g ABS UL 2m 200 g ABS UL 2m 750 g ABS UL Mode of Operation The output voltage is proportional to the highest current value in the 3 conductors which are drawn through the holes of the current metering transformer. By drawing each conductor several times through the hole, the output voltage is multiplied by the number of times each conductor is drawn through the hole. This makes it possible to use the current metering transformers, e.g. type MP 3005, for measuring far below the nominal range. Wiring Diagram Black Latch/hysteresis Power supply S 178 Dimensions MP 3005, MP 3020 MP 3100, MP 3500 2 Specifications are subject to change without notice (28.10.99) |
Price & Availability of MP3005
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |