If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
CEPT/T1 TEW5502 is designed and approved to be used as an OUTPUT transformer in T1/CEPT applications with the following devices: Crystal Level One 61535A,61574A 61575, 6158A 304A, 305A Output Transformer Typical applications are: * * * Primary rate ISDN network nodes. PBX or computer to T1/CEPT Digital Trunks. TDM Multiplexers. TEW5502 Complies with ANSI T1.408 and CCITT I.431 with regards to Longitudinal Balance. MECHANICAL 120 6 Top view Line 5 3 1 6 4 2 3 75 5 2 Device Com. 4 1 All dimensions are in mm. ELECTRICAL SPECIFICATION 5502.chp TEW5502-1 100 1 : 1.15 n/a > 1.8 -2 75 1:1 n/a > 1.5 -3 120 1:1.26 n/a > 2.0 -4 120 75 1 : 1.26 1:1 > 2.0 Line Impedance Turns ratio Inductance (mH) DCR (Ohms) Longitud. Bal. Pulse Mask Dielectric Strength (Vrms) (4 - 6) (4 - 5) (1 - 3) : (4 - 6) (1 - 3) : (4 - 5) (4 - 6) (4 - 6) (1 - 3) ISSUE: A 94/11/10 T1.408 T1 1500 I.431 CEPT 1500 I.431 CEPT 1500 I.431 CEPT 1500 Filtran Limited 229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3, Tel : (613) 226 -1626 Fax : (613) 226 -7124 2-46 |