Current Transducer LB 1000-SI/SP2 For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 1000 A Electrical data IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with 15 V ISN KN VC IC Vd @ 1000 A max @ 1500 A max 1000 0 .. 1500 RM min RM max 0 0 25 5 A A mA V mA kV Features * Closed loop (compensated) current transducer using the Hall effect * Insulated plastic case recognized according to UL 94-V0. Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 200 1 : 5000 15 21 + IS 6 Special features * Better zero crossing performance * TA = + 10C .. + 50C * Shield between primary and secondary. Accuracy - Dynamic performance data XG L Overall accuracy @ IPN , TA = 25C Linearity Offset current @ IP = 0, TA = 25C Thermal drift of IO + 10C .. + 50C Response time 1) @ 90 % of IP max di/dt accurately followed Frequency bandwidth (- 1 dB) 0.3 < 0.1 Typ Max 0.4 0.2 % % mA mA s A/s kHz Advantages * * * * * * * Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability. IO IOT tr di/dt f 0.1 <1 > 50 DC .. 100 General data TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 70C Mass Standards 2) + 10 .. + 50 - 25 .. + 85 40 700 EN 50178 C C g Applications * AC variable speed drives and servo motor drives * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies (UPS) * Switched Mode Power Supplies (SMPS) * Power supplies for welding applications. Notes : 1) 2) With a di/dt of 100 A/s A list of corresponding tests is available 000901/0 LEM Components w w w.lem.com Dimensions LB 1000-SI/SP2 (in mm. 1 mm = 0.0394 inch) Front view Left view Secondary terminals Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V Connection Top view Mechanical characteristics * * * * General tolerance Fastening Primary through-hole Connection of secondary 0.5 mm 4 slots 7 mm 40 mm Faston 6.3 x 0.8 mm. Remarks * IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed 100C. * Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. |
Price & Availability of LB1000-SI |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |