![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Current Transducer LA 100-S/SP1 For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 100 A 0629 Electrical data I PN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with 15 V ISN KN VC IC Vd @ 100 A max @ 200 A max 100 0 .. 200 RM min RM max 0 0 50 1 : 2000 15 22 + IS 3 180 50 A A mA V mA kV Features * Closed loop (compensated) current * Insulated plastic case recognized according to UL 94-V0. transducer using the Hall effect Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 min Special features * I P = 0 .. 200 A * K N = 1 : 2000 Accuracy - Dynamic performance data XG Advantages 0.5 < 0.1 Typ Max 0.1 0.4 % % mA mA s A/s kHz L Overall accuracy @ IPN, T A = 25C Linearity error Offset current @ IP = 0, T A = 25C Thermal drift of IO - 10 C .. + 70C Response time 1) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) IO IOT tr di/dt f 0.2 <1 > 50 DC .. 150 * * * * * * * Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability. General data TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ T A = 70C Mass Standards 2) - 10 .. + 70 - 25 .. + 85 85 65 EN 50178 C C g Applications * AC variable speed drives and servo * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies * Switched Mode Power Supplies * Power supplies for welding applications. (SMPS) (UPS) motor drives Notes : 1) 2) With a di/dt of 50 A/s A list of corresponding tests is available. 060901/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 1/2 LEM www.lem.com Dimensions LA 100-S/SP1 Front view (in mm. 1 mm = 0.0394 inch) Left view Secondary terminals Terminal Terminal Terminal Terminal + M 0 : : : : supply voltage + 15 V supply voltage - 15 V measure NC Connection Top view Mechanical characteristics * * * * General tolerance Fastening Primary through-hole Connection of secondary 0.3 mm 2 holes 3.2 mm 16 x 10 mm Molex 5045-04/AG Remarks * IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed * Dynamic performances (di/dt and response time) are best * In order to achieve the best magnetic coupling, the primary * To measure nominal currents of less than 100 A, the optimum accuracy is obtained by having several primary turns (nominal current x number of turns < 100 At). windings have to be wound over the top edge of the device. with a single bar completely filling the primary hole. 100C. 060901/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 2/2 LEM www.lem.com |
Price & Availability of LA100-S06
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |