 Current Transducers, HY50-P
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
50 A
Electrical data
Primary nominal r.m.s. current IPN (A) 50 Primary current measuring range IP (A) 150 Primary conductor (mm) Type
1.6 x 3.5
HY 50-P
Features
V mA kV V M V k
VC IC IP Vd Vb R IS VOUT ROUT RL
Supply voltage ( 5 %) Current consumption Overload capability (1 ms) R.m.s. voltage for AC isolation test, 50/60Hz, 1 min R.m.s. rated voltage,safe separation Isolation resistance @ 500 VDC Output voltage @ IPN, RL = 10 k, TA = 25C Output internal resistance Load resistance
15 10 50 x IPN 2.5 5001) > 1000 4 100 >1
* Hall effect measuring principle * Galvanic isolation between primary * Isolation voltage 2500 V~ * Compact design for PCB mounting * Low power consumption * Extended measuring range (3 x IPN) * Insulated plastic case recognized
according to UL 94-V0. and secondary circuit
Accuracy - Dynamic performance data
Advantages
<1 % < 1 % of IPN < 40 mV < 15 mV 1.5 mV/K 3 mV/K < 0.1 %/K <3 s > 50 A/s DC .. 50 kHz
X
L
VOE VOH VOT TCG tr di/dt f
Accuracy @ IPN, TA = 25C (without offset) Linearity 2) (0 .. IPN) Electrical offset voltage, TA = 25C Hysteresis offset voltage @ IP = 0 after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of IP di/dt accurately followed Frequency bandwidth 3) (0 .. - 3 dB)
* Easy mounting * Small size and space savings * Only one design for wide current * High immunity against external
interference ratings range
typ max
Applications
* General purpose inverters * Switched-Mode Power Supplies * AC motor speed control * Battery supplied applications * Uninterruptible Power Supplies (UPS) * Power supplies for welding
applications. (SMPS)
General data
TA TS m Ambient operating temperature Ambient storage temperature Mass Standards 4) - 10 .. + 80 - 25 .. + 85 < 14 EN50178 C C g
Notes :
1) 2)
Pollution class 2, overvoltage category III Linearity data exclude the electrical offset. 3) Please refer to derating curves in the technical file to avoid excessive core heating at high frequency 4) Please consult characterisation report for more techinical details and application advises. 980723/2
LEM Components
www.lem.com
HY 50- P D im e ns io ns
(in m m )
36 .0 M ax . 32 .0 M ax .
JA PA N
18 .0 12 .0 12 M ax .
HY 50 - P 97 08
1.6
3 .5
3 .00 .5 3 x 2 .54
5 .50 .2 7 .00 .2 17 .5 0 .3
1.6 0 .3 3 .90 .3
1234
5
6
PC B M O U NT ING D IM E NS IO NS (in m m 0 .1, ho le -0 , +0 .2 )
3 .5
4 ho le s d ia 1 ho le s d ia 2 .2
PIN A R RA NG EM E NT
3 x 2 .54 5 .5 17 .5
LEM reserves the right to change limits and dimensions.
1 2 3 4
+ 15V -- 15V O UT P UT 0V
5 PR IMA RY IN 6 PR IMA RY O UT