Part Number Hot Search : 
CR18W 2100D 015020 39040 BD7996 MTP5P25 T15M256B GUF30A
Product Description
Full Text Search
 

To Download HLC-1520A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Tadiran HLC (Hybrid Layer Capacitor) Model HLC-1520A
1. Scope This data sheet describes the mechanical design and performance of Tadiran HLC (Hybrid Layer Capacitor) model HLC-1520A, optimized for extreme temperatures, used in a Pulses Plus battery. 2. Characteristics 2.1. Physical Length: Diameter: Weight: Discharge Discharge capacity (at RT): When charged to 3.67V: When charged to 3.90V: Discharge end voltage: 140 A*sec 210 A*sec 2.5V (discharge below 2.5V at RT and discharge below 2 V at -40oC may increase the HLC internal impedance) Continuous: 500 mA Pulse: 2 A 2.2.2. Charge (constant current) Max. charge voltage: Max. charging current: 3.95 V 25 mA 19.7 0.3 mm. 15.1 mm. max. 7.7 0.2 gr. 2.1.1. 2.1.2. 2.1.3. 2.2. 2.2.1.
Electrical
Maximum discharge current:
Rev. D, April 05. Page 1 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN'S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
2.2.3. Shelf life (Reversible Capacity): The table below describes the shelf life at different storage temperatures to 80% of initial capacity specified at paragraph 2.2.1. Temperature RT 60C 85C 2.2.4. HLC used independently 3 years 4 weeks 1 week HLC in Pulses Plus battery 10 years 7 years At least 1 year
Self discharge current in Pulses PlusTM battery: At RT: At 80 C:
o
1A 5A
2.2.5.
Number of charge-discharge cycles to 80% of initial capacity : 100% DOD Charged to 3.67V Charged to 3.90V 4000 1000 10% DOD 40,000 10,000 1% DOD 400,000 100,000
DOD (Depth Of Discharge)
2.2.6.
Cell impedance:
Less than 250 mOhm (at RT @ 1kHz)
Rev. D, April 05. Page 2 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN'S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
2.2.7.
Performance Data:
VOLTAGE vs. TIME CURVES for HLC-1520A at Li/SOCl2 potential, 200 mA.
3.8 3.6 3.4 3.2 3.0 2.8 2.6 2.4 2.2 2.0
1 10 100 1000 10000
VOLTAGE V
TIME [msec.]
-40C -25C RT 72C
VOLTAGE vs. TIME CURVES for HLC-1520A at Li/SOCl2 potential, 350 mA.
3.8 3.6 3.4 VOLTAGE V 3.2 3.0 2.8 2.6 2.4 2.2 2.0
1 10 100 1000 10000
TIME [msec.]
-40C -25C RT 72C
Rev. D, April 05. Page 3 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN'S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
VOLTAGE vs. TIME CURVES for HLC-1520A at Li/SO2Cl2 potential, 200 mA.
4.0 3.8 3.6 3.4 3.2 3.0 2.8 2.6 2.4 2.2 2.0
1 10 100 1000 10000
VOLTAGE V
TIME [msec.]
-40C -25C RT 72C
VOLTAGE vs. TIME CURVES for HLC-1520A at Li/SO2Cl2 potential, 350 mA.
4.0 3.8 3.6 3.4 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1 10 100 TIME [msec.] -40C -25C RT 72C 1000 10000
Rev. D, April 05. Page 4 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN'S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
VOLTAGE V
Discharge capacity vs. OCV for HLC-1520A (at RT, 50mA discharge)
4.0 3.8 3.5 V OCV 3.3 3.0 2.8 2.5 0.1 1 10 CAPACITY [A*sec] 100 1000
2.3.
Safety: The HLC successfully passed the following tests: Short circuit at RT Short circuit at 55C Compression Impact Overcharge High temperature exposure Shock and vibration Forced discharge
2.3.1.
Tadiran Batteries performed the tests according to UL 1642 specification for lithium batteries. The HLC was approved by UL under file no. MH12193 issued on December 7, 2000. 2.3.2. The HLC is not restricted for air transportation.
Rev. D, April 05. Page 5 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN'S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.
2.4.
Temperature range: HLC used independently Operating temperature Storage temperature -30 to 60C -30 to 60C HLC in Pulses Plus battery -40 to 85C -30 to 60C
Warning:
The HLC is designed for use in a Pulses Plus battery or in low charge current as specified only. The HLC may explode or violently vent if over-charged above 4.4V. Charging the HLC at above 3.95V may lead to capacity loss and / or internal impedance rise. Do not charge the HLC higher than 4.1V, over discharge, short circuit, heat above 100C, incinerate or expose content to water.
Rev. D, April 05 Page 6 of 6
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND STORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENTATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN'S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN.


▲Up To Search▲   

 
Price & Availability of HLC-1520A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X