 Issue Date
1. Title 2. Item number
w
w
1 S Name 2 3 4 5 6 1 Series ta 2 Display area: 96x192mm a D 3 Included with driver (D) . 4 Dot matrix: 16(Vertical) x 32(Horizontal) dot w 5 Emitted color: R(Red)/ G(Green) 6 Specific symbol
om March 11. 2002 .c LED Outdoor Dot Matrix Display Module 96 4U t eRLU 96 D - 1632 - RG - 01 he
S-CD941 SPECIFICATION
3. Specification 3a. Absolute Maximum Ratings
Item Logic Voltage LED Voltage Input Voltage Symbol VCC VLED VI Topr1 Operating Temp. Topr2 Topr3 Storage Temp. Humidity Range Tstg Rating - 0.3~+6.0 - 0.3~+3.2 - 0.3~VCC+0.3 - 20~+25 - 20~+50 Unit V V V
o o o o
C C C C
3b. Mechanical Rating
Item Displayed Color Dot Dimension
Dot- to- Dot Pitch Number of dots Display area dimension Drive method Number of modules connected Module Weight
w
w
.D w
t a
- 20~+65
- 25~+85 30~ 90
S a
e h
Rating
100% when illuminated (each color) 50% when illuminated (each color) 25% when illuminated (each color)
t e
U 4
Remark
.c
m o
%RH
Unit
Red, Yellow Green, Orange (red, yellow and green illuminate same time) mm mm dot mm
3.0 x 2.5 6.0 + 0.2 16 x 32 (512) 95.7 x 191.7 + 0.2 1/4 Dynamic illumination Max 16 180
Module
OKAYA Electric America, Inc. 503 Wall St., Valparaiso IN 46383
w whttp://www.okaya.com Phone: 800-852-0122 Fax: 219-477-4856 w
.D
a
aS tg
ee h
4U t
om .c
S-CD941
Issue Date March 11. 2002
SPECIFICATION
3c. Electrical Specifications
Item LogicVoltage LED Voltage Input Voltage Symbol VCC VLED VIL VIH IIL IIH ICC ILED fCLK Rating
MIN. TYP MAX
Unit V V V mA A mA A MHz
Remark
4.5 2.8 0.0 3.9 -
5.0 3.0 -
5.5 3.2 1.3 VCC 1.3 0.2 150 12 5
Input Current
Current Comsumption Operating Frequency
3d. Optical Characteristics (TA=25oC, VCC=5.0V, VLED=3.0V)
Item Luminous Intensity Dominant Wavelength Half Angle Luminous Intensity Luminous Intensity (Factory setting) Red Yellow, Green Horizontal Vertical Red Yellow, Green Symbol IV d 2 1/2 2 1/2 IVR IVG Rating
MIN TYP MAX
Unit cd/m2 nm
Remark *1
240 240
600 660 570 30 30 300 300
360 360
Degree
cd/m2
*2
Variation of luminous intensity between the dot Variation of luminous intensity between the unit
within 1.7 times within 1.5 times
*1: Conditions- The intensity with both Red and Green active. *2: Conditions- Ta=25+3oC, VCC=5.0V, VLED=4.5V Average luminous intensity including non-emitting part immediately after adjustment.
3e. Life Expectancy (Ta=25oC, VCC=5.0V, VLED=3.0V)
Item Life expectancy Conditions Rating Unit Hr
Red and Green both active 30,000 Hr. min. (Time to half- life of initial luminous intensity) Topr=25oC
OKAYA Electric America, Inc. 503 Wall St., Valparaiso IN 46383
Phone: 800-852-0122 Fax: 219-477-4856 http://www.okaya.com
S-CD941
Issue Date March 11. 2002
SPECIFICATION
4. Description of Signals 4-a. Power Supply (CN1: The side of the main body: 1-353524-8 : AMP)
Item VLED VCC GND Terminal Number 1 2~9 10 ~ 18 for logic for LED Power supply ground Functions Remark
4-b. Input Signal (CN2: The side of the main body: B10B-PH : JST)
Item A1 A0 LATCH Red Data Green Data Shift Clock Red Enable Green Enable NC GND Terminal Number 1 2 3 4 5 6 7 8 9 10 Signal ground (internal connection of power supply ground and signal ground) Row address selection signal Latch signal of display data. Display data at shift register is transferred by low level and latched by high level Display data input of red LED. H: ON, L: OFF (shift from 1 to 128) Functions Remark
Display data input of yellow, green LED. H: ON, L: OFF (shift from 1 to 128) Data shifting clock of the shift register. Start- up of the clock: ddata shifting by changing from L to H. Control signal of turning on/off of red LED. H: Turn Off, L: Turn On Control signal of turning on/off of yellow, green LED. H: Turn Off, L: Turn On
4c. Output Signal (CN3: The side of the main body : B10B-PH : JST) Output each input signal through buffer. Attaches to the input connector for the next row.
Item A1 A0 Latch Red Data Green Data Shift Clock Red Enable Green Enable NC GND Terminal Number 1 2 3 4 5 6 7 8 9 10 Signal ground (internal connection of power supply ground and signal ground) Functions Outputs the input signal through buffer Outputs the input signal through buffer Outputs the input signal through buffer Outputs the input signal through buffer 128- bit shift register and buffer Outputs the input signal through buffer 128- bit shift register and buffer Outputs the input signal through buffer Outputs the input signal through buffer Outputs the input signal through buffer Remark
OKAYA Electric America, Inc. 503 Wall St., Valparaiso IN 46383
Phone: 800-852-0122 Fax: 219-477-4856 http://www.okaya.com
S-CD941
Issue Date March 11. 2002
SPECIFICATION
5. Interface 5a. Connection The display module requires a display controller and DC power supply for proper operation.
LED Display Module LED Display Module LED Display Module External display controller
VLED V CC GND Part of DC power supply
5b. Input method of Display Data The display data is entered by selecting the red or green data for the 128 pixels starting at the upper right of the screen. The following table shows display row and row address selection signal (A1, A0).
Row address A1 A0
2 1 0 0 1 1 18 17 0 0 1 1 34 33 0 0 1 1 50 49 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
Front look of LED display surface
80 79 LL LL LL LL 96 95 LL LL LL LL 112 111 LL LL LL LL 128 127 LL LL LL LL 114 113 64 63 98 97 48 47 82 81 32 31 66 65 16 15 LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL LL
OKAYA Electric America, Inc. 503 Wall St., Valparaiso IN 46383
Phone: 800-852-0122 Fax: 219-477-4856 http://www.okaya.com
S-CD941
Issue Date March 11. 2002
SPECIFICATION
5c. Input-output circuit
CN2 Input
VCC CN3
Output
5d. Timing chart
tsd Shift Clock Red Data Green Data Latch Red Enable Green Enable Address (A0,A1) thd td f
N tsE-LT tWLT tWEN fEN tsLTA
Rating
MIN TYP
N+1 thLTE
thA-E
Item Clock Frequency Data set- up time Data hold time Clock - latch time Latch pulse width Enable pulse width Enable latch width Latch- enable time Latch- address time Address- enable time
Symbol f tsd thd td tWLT tWEN tsE-LT thLT-E tsLT-A thA-E
MAX
Unit MHz ns ns ns ns s ns s ns s
Remark
100 100 200 200 11 200 11 500 10
-
5 -
6. Handling 6a. Installation i. Securely mount using the specified torque (3 Kgf/cm). ii. The module spacing should be vertical 96mm and horizontally 192mm. iii. To insure proper water seal, care must be taken that where the plate and waterproof packing material are bonded remains free from deformation or penetration of foreign material. ix. Make sure that water proof packing material does not stick out of the frame when installing the modules. OKAYA Electric America, Inc. 503 Wall St., Valparaiso IN 46383
Phone: 800-852-0122 Fax: 219-477-4856 http://www.okaya.com
S-CD941
Issue Date March 11. 2002
SPECIFICATION
6b. Heat Using a large number of modules can cause degradation due to heat radiation. Care should be taken to prevent the temperature over the case's surface from exceeding 65C. The use of fans or reduction of illumination intensity may be required for heat control. Fig. 1 shows the ratio of illumination to ambient temperature.
Ambient temperature vs. Illumination ratio
100%
Illumination ratio
80% 60% 40% 20% 0% -20 -10 0 10 20 30 40 50 60 70 80 90 100
Fig.1
Ambient temperature vs. (oC)
6c. Chemical and abrasion withstand capability To clean the surface of the module, use a soft cloth and a neutral detergent. 6d. Static These modules contain static sensitive CMOS-IC circuitry. Antistatic measures must be followed during assembly or testing to prevent damage to the electronics. 6e. Connecting Cable To make electrical connection to the modules use only the provided or specified connectors. Use extreme caution to prevent damage when attaching or detaching the connectors. 6f. Others i. Do not attempt to adjust the pre-set resistor used for luminous intensity adjustment. ii. Take care to avoid electromagnetic interface when assembling and installing the modules. iii. Be sure to disconnect power when installing or disassembling the module. ix. Caution: excessive ambient electrical noise may cause modules to malfunction. 7. Included Parts (refer to the figure 11a and 11b)
Number 1 2 Power cable Signal cable 1 1
OKAYA Electric America, Inc. 503 Wall St., Valparaiso IN 46383
Phone: 800-852-0122 Fax: 219-477-4856 http://www.okaya.com
S-CD941
Issue Date March 11. 2002
SPECIFICATION
8. External forms and dimensions
15
191.7+0.2
95.7+0.2
67.0
40.0
67.0 6-M3.0
CN1
78.0
CN2
9a. Included Parts1: Power cable
CN3
9b. Included Parts2: Signal cable
230+5
Contact: 353907-1 353918-1 Housing: VHR-6Nx1
300+5
Cable: UL1007 AWG26 Brown 1Pin Red 2~9Pin Black 10~18Pin
Cable: UL1007 AWG24 White Contact: SPH-002T-PO 5S(JST)x20 Housing: PHR-10(JST)x2 Connection: 1x1
(Unit: mm) OKAYA Electric America, Inc. 503 Wall St., Valparaiso IN 46383
Phone: 800-852-0122 Fax: 219-477-4856 http://www.okaya.com


▲Up To Search▲   

 
Price & Availability of RLU96

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X