Harsh Environment Fiber Optic Connectors MF 14 and MF 17 Series MU SC FC Harsh Environment sFeatures 1. 2 Fibers (MF14 series), 4 Fibers (MF17 series), or Optical/Electrical Hybrids are available. 6 fibers (MF22 series) available. 2. Incorrect Insertion Prevention. Guide key (plug) and key slot (receptacle) are designed for prevent incorrect insertion. Attenuators 3. Plug, receptacle fully mated condition satisfy IP67 wateroof Performance. 4. For more than 10 years, MF series has been designed and installed in many harsh environmental applications. Please contact us if you have any requests. HIROSE will offer excellent solutions to meet your requirements. sApplications Terminators Outdoor optical transmission systems, LAN, CATV, ATM, Base station, industrial optical/electric lines. 55 sProduct Specifications Ratings Operating temperature range -25C to +70C Storage temperature range -25C to +70C MU Item Optical characteristics Insertion Loss Durability (cycles, mating/un-mating) Vibration Shock Humidity (Temperature/ humidity- cycles) Change of temperature Dry heat Cold Salt Mist Waterproof Test Method Wavelength 1310nm (LD) Specifications 1.0dB max. (Note) Mechanical characteristics 100 times Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, acceleration of 98.1m/s2, 2 hours in each of the 2 axis. Acceleration of 981 m/s2, 6 ms duration, sine halfwave waveform, 3 cycles in each of the 2 axis. -10C to 65C, humidity: 90% to 96% 10 cycles -40C to +75C 42 cycles 960 hours at 85C 960 hours at -40C 1000 hours in a 5% concentration of salt mist Inside air pressure 4.90kPa for one minute No visible corrosion. No air bubble leakege, IP67 1) Insertion loss fluctuation after test: 0.3dB max. 2) No visible damage, dislocation of clamp or cable. 1) Insertion loss fluctuation after (test) : 0.3dB max. 2) No visible damage, dislocation of clamp or cable. SC FC Note: Insertion loss herein means only connection loss. sMaterials Part Material Aluminum alloy Synthetic resin Zinc alloy Brass Synthetic rubber Stainless steel Brass Zirconia or Copper alloy Harsh Environment Environmental characteristics Plug and Receptacle Housing Ferrule case Strain relief Protective cap and clamp Rubber boot and O-rings Screws, springs, and steel wire Washer Split sleeve Attenuators s Important Notice 1. Please ask HIROSE when you assemble the MF connectors for special cables. Some cables can not be used for the connectors. 2. MF series use SC/PC zirconia ferrules. Please see page 33. Terminators 56 sBayonet lock qPlug Housing B C MU OD OA E SC Part Number MF14B-WP*S01-0200 MF17B-WP*S01-0400 Number of Fibers 2 4 OA 24 27 B 184.7 116.5 C 69 52 OD 24 27 E 21 21 * indicates cable diameter. 8, 9 and 10mm, diameter cables are appicable. qSquare Flange Receptacle Housing C ME B 3 FC 4- O3 .3 OD A Harsh Environment OF G Part Number MF14B-WRF01-0200 MF17B-WRF01-0400 Number of Fibers 2 4 MA 30 35 B 10 10 C 45.5 51.5 OD 20.5 25.5 ME 23 27 OF 24 27 G 18.7 18.7 Note: Up to 3 mm cables are applicable. Attenuators qBulk Head Receptacle Housing E HEX B C 3 OD A Terminators OF G Part Number MF14B-WRB01-0200 MF17B-WRB01-0400 Number of Fibers 2 4 MA 30 34 B 17.5 17.5 C 45.5 51.5 OD 20.5 25.5 ME 28 32 OF 24 27 G 18.7 18.7 Note: Up to 3 mm cables are applicable. 57 sThreaded lock qPlug housing MU B C OA F SC OD E Part Number MF14S-WP*S01-0200 MF17S-WP*S01-0400 Number of Fibers 2 4 OA 24 27 B 184.7 116.5 C 69 52 OD 24 27 E 20.8 20.8 F M201 M221 *indicates the cable diameter. 8, 9 and 10mm, diameter cables are applicable. qSquare Flange Receptacle Housing FC C MF E B 3 MA 4- O3 .3 Harsh Environment OG0.3 H Part Number MF14S-WRF01-0200 MF17S-WRF01-0400 Part Number 2 4 MA 30 35 B 10 10 C 45.5 51.5 OD 20.5 25.5 E M201 M221 MF 23 27 OD OG 24 27 H 18.5 18.5 Note: Up to 3 mm cables are applicable. Attenuators qBulk Head Receptacle Housing E B C 3 F HEX Terminators OG H Part Number MF14S-WRB01-0200 MF17S-WRB01-0400 Part Number 2 4 MA 31 34 B 17.5 17.5 C 45.5 51.5 OD 20.5 25.5 E M201 M221 MF 30 32 OD A OG 24 27 H 18.5 18.5 Note: Up to 3 mm cables are applicable. 58 BPanel cut-out qSquare Flange Receptacle MU OA SC Part Number MF14B-WRF01-0200 4O3 A 21 21 26 26 B 23 23 27 27 MF14S-WRF01-0200 .3 MB MF17B-WRF01-0400 MF17S-WRF01-0400 Panel thickness: 2mm to 4.5mm qBulk Head Receptacle FC B Harsh Environment OA Part Number MF14B-WRB01-0200 Panel thickness: 2mm to 4.5mm MF14S-WRB01-0200 MF17B-WRB01-0400 MF17S-WRB01-0400 A 22.2 24.2 24.2 24.2 B 21.2 23.2 23.2 23.2 Attenuators Terminators 59 Harsh Environment Fiber Optic Connector MF22 Series MU SC FC Harsh Environment sFeatures 1. 6 Fibers or Optical /Electric Hybrids are available 2 fibers (MF14), 4fibers (MF17) available. Please contact us if you have any requests. HIROSE will offer excellent solutions to meet your requirements. Receptacles Guide key slot 1 6 2 2. Incorrect Insertion Prevention Five guide keys positioned at specific angles assure that the connector will mate only with the corresponding assembly. Attenuators 5 4 3 3. Plug, receptacle fully mated condition satisfy IP67 waterproof performance. 4. Harsh environment applications The connector's outer surfaces are covered with heat baked hard coating and all internal connections are protected by seals. Plugs Terminators Guide key 5. Cable Termination The connector will terminate with a majority of cables having outside diameter from 7mm to 12mm. Please contact Hirose for other applicable cable. 1 2 6 3 5 4 sApplications Outdoor optical transmission systems, LAN, CATV, ATM, and other applications requiring environmentally protected optical or electrical connections. 61 sProduct Specifications Ratings Operating temperature range -40C to +75C Storage temperature range -40C to +85C MU Item Optical characteristics Insertion Loss Durability (cycles, mating/un-mating) Vibration Shock Humidity (Temperature/ humidity- cycles) Change of temperatice Dry heat Cold Salt mist Waterproof Test Method Wavelength 850nm (LD) Specifications 0.7dB max. (Note) Mechanical characteristics 500 times Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, acceleration of 98.1m/s2, 2 hours in each of the 2 axis. Acceleration of 981 m/s2, 6 ms duration, sine halfwave waveform, 3 cycles in each of the 2 axis. -10C to 65C, humidity: 90% to 96% 10 cycles -40C / +75C 42 cycles 336 hours at 85C 240 hours at -40C 1000 hours in a 5% concentration of salt mist Inside air pressure 4.90kPa for one minute No visible corrosion. No air bubble leakege, IP67 1) Insertion loss fluctuation after test: 0.3dB max. 2) No visible damage, dislocation of clamp or cable. 1) Insertion loss fluctuation (after test): 0.3dB max. 2) No visible damage, dislocation of clamp or cable. SC FC Note: Insertion loss herein means only connection loss. sMaterials Part Material Aluminum alloy Synthetic resin Zinc alloy Synthetic resin Synthetic rubber Stainless steel Brass Zirconia or Copper alloy Harsh Environment Environmental characteristics Plug and Receptacle Housing Ferrule case Strain relief components Protective cap and clamp Rubber boot and O-rings Screws, springs, and ball chain Washer Split sleeve Attenuators s Important Notice 1. Please ask HIROSE when you assemble the MF connectors for special cables. Some cables can not be used for the connectors. 2. MF series use SC/PC zirconia ferrules. Please see page 33. Terminators 62 sThreaded lock qPlug housing MU 126 121 Tr302 O34 SC Part Number MF22S-WDP*S01-0600 Number of Fibers 6 *indicates cable diameter. qBulk head receptacle housing 43 BPanel cut-out FC 43 42 HEX 2 3 33 +0.5 0 O32 1 4 O34 +0 0 6 5 .5 O4 5 20 32.35 Harsh Environment Tr302 Panel thickness: 1mm to 4mm Part Number Number of Fibers MF22S-WDRB01-0600 6 Note: Up to 3 mm cables are applicable. Attenuators Terminators 63 sTools qPlug assembly tool MU SC Part Number MF22S-T2 CL No. 709-0065-0 Harsh Environment FC qCrimp tool for receptacle assembly Part Number HSC-T3 CL No. 704-0287-0 Terminators Attenuators 64 |
Price & Availability of MF14B-WRF01-0200 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |