If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
UL (R) LSI/CSI LS7310-7313 (631) 271-0400 FAX (631) 271-0405 LSI Computer Systems, Inc. 1235 Walt Whitman Road, Melville, NY 11747 A3800 AC POWER CONTROLLERS FEATURES: * 10 I/Os to Select/Indicate up to ten Power Levels * Inputs activated by Touch or Pushbutton Switch * Output switches pure and precise AC Power to Load * Operates with 50Hz/60Hz line frequency * Rugged, latchup-free process technology * +10V to +14V operation (Vss-VDD) * LS7310 thru LS7313 (DIP); LS7310-S thru LS7313-S (SOIC) - See Figure 1 APPLICATIONS: Universal and shaded-pole motor speed control for modern appliance designs. Eliminates awkward mechanical switch assemblies and multi-tapped motor windings. DESCRIPTION: The LS7310-LS7313 are MOS integrated circuits specifically designed for motor speed control applications in appliances such as blenders, etc. I/Os (PLs) are provided for selecting/ indicating from one to ten power levels. The LS7310 and 7311 are designed for pushbutton control. The LS7312 and LS7313 are designed for touch control. (See Fig.4A and 4B) INPUT/OUTPUT DESCRIPTION: PL1-PL10 (Pins 1-9, 18) Ten inputs/outputs for selecting ten output phase angles (power levels). When no power level is selected (such as after system power-up), PL1-PL10 all act as inputs. When a power level is selected by applying a logic zero at one of these inputs for TH time (See Dynamic Characteristics), the selected input switches status to become an output in order to drive a display, such as an LED. It switches back to the input state only when another PL input is activated. (See Note 1) CONNECTION DIAGRAM - TOP VIEW PL2 PL3 PL4 PL5 PL6 PL7 PL8 PL9 PL10 1 2 3 4 5 6 7 8 9 LS7310 January 1997 18 PL1 17 TRIG 16 Vss (+V) 15 SYNC 14 CAP 13 RUN 12 P U L S E 11 OFF 10 V DD (-V) PULSE (Pin 12) A logic 0 applied to this input turns the TRIG output on for as long as the PULSE input is maintained. The PULSE input however, has no effect if no power level is in selection or if the TRIG output has already been turned on by means of the RUN input. (See Note 1) SYNC (Pin 15) Input for PLL reference frequency (50Hz/60Hz). All internal clock frequencies are synchronized with the SYNC input. CAP (Pin 14) Input for component connection for the PLL filter capacitor. TRIG (Pin 17) This output is designed to drive a triac in series with the load and control its firing angle with respect to the AC line. The LS7310 and LS7312 provide a nominal 33s output pulse width. Since some motors have large inductive loads producing a large phase delay between voltage and current, a wider output pulse may be required. The LS7311 and LS7313 produce a 1ms output pulse width. Otherwise, these parts are identical to the LS7310 and LS7312, respectively. RUN (Pin 13) When a logic 0 is applied to the RUN input for TH time, the output (TRIG) is turned on at a phase angle selected earlier by one of the PL I/Os. If no power level was selected prior to the application of the RUN input, the circuit remains unaffected. Note that once the TRIG output has been enabled, its phase angle can be altered by applying any other PL input without the Vss (Pin 16) need to apply the RUN input again. (See Note 1) Supply voltage positive terminal. OFF (Pin 11) When a logic 0 is applied to this input for TH time, TRIG output is turned off, if it was on. If TRIG was already off, the circuit remains unaffected. Note that OFF input does not alter the power level selected by a PL input. Following an OFF operation, TRIG can be turned on at the previous phase angle by applying the RUN input. (See Note 1) 7310-011697-1 VDD (Pin 10) Supply voltage negative terminal (ground). NOTE 1: LS7310, LS7311 have an internal pullup resistor on this input and LS7312, LS7313 do not. (See DC Electrical Characteristics.) LSI FIGURE 1 FIGURE 2. LS7310-LS7313 BLOCK DIAGRAM RUN 13 + LEVEL 1 POWER LEVEL ROM LEVEL 10 PULSE 12 + OFF 11 + DRIVER CONTROL LOGIC PHASE ANGLE POINTER DIGITAL COMPARATOR DRIVER 17 TRIG PL1 18 + DRIVER PHASE-LOCKED LOOP AND CLOCK GENERATOR PL10 9 V DD + SYNC 15 V DD + 14 CAP V SS V SS TABLE 1. TRIG PHASE ANGLES (1) FIGURE 3. TRIG PHASE ANGLE O PL INPUT 1 2 3 4 5 6 7 8 9 10 (1) TRIG O 78 86 93 100 107 112 119 127 137 149 LOAD POWER % (2) 37 46 53 60 69 74 79 86 92 97 SYNC O TRIG TW (2) The TRIG Phase Angles shown in TABLE 1 are referenced to the SYNC input. In the Application Schematic shown in Figure 4A, SYNC is delayed by 7 from the AC line. Therefore, actual Phase Angles with respect to the AC line are 7 less than TABLE 1 values. TABLE 1 values are mask programmable. The percentage of Full Power delivered to a resistive load by the Triac Switch. FIGURE 4 VALUE TABLE CONDITION (1), (3), (5) (1), (3), (6) (1), (4), (5) (1), (4), (6) (2), (3), (5) (2), (3), (6) (2), (4), (5) (2), (4), (6) C2(F) 0.22 0.10 0.47 0.33 0.47 0.33 0.68 0.47 C5(F) 100 100 220 220 220 220 220 220 FIGURE 4 NOTES NOTE 1: Value for 5mA LEDs NOTE 2: Use zener which produces 6.2V 5% at 500A or less, i. e. P/N MZ4627 NOTE 3: R6-C6 Snubber Network may be required for large inductive loads. NOTE 4: Tie all unused touch inputs together and return to Vss through 100k Ohm, 1/4W resistor. (1) 33s TRIG pulse (LS7310, LS7312) (2) 1ms TRIG pulse (LS7311, LS7313) (3) No LEDs (4) 5mA LEDs (5) 115VAC, C2 = 200V (6) 220VAC, C2 = 400V 7310-011697-2 FIGURE 4A. P G C1 R6 C6 MT1 T MT2 APPLICATION SCHEMATIC FOR LS7310-LS7313 + C5 Z1 C4 R9 C3 AC MAINS SEE NOTE 3 L C2 D1 10 V DD PL10 15 SYNC 17 TRIG 14 CAP 16 V SS RUN 13 LS7310 - LS7313 PL1 18 OFF 11 PULSE 12 M R2 R1 9 PL10 N PL1 OFF PULSE RUN R5 R4 Z2 SEE NOTE 4 PL10 PL1 OFF PULSE RUN PL10 PL1 OFF PULSE RUN R8 R7 R8 R7 R8 R7 R8 R7 R8 R7 Vss R8 R8 TP TP R8 TP R8 TP R8 R3 VDD FIGURE 4B. PUSHBUTTON INTERFACE FOR LS7310, LS7311 TP FIGURE 4C. TOUCH INTERFACE FOR LS7312, LS7313 C1 = 0.15F, 200V (400V) * C2 = See Figure 4 Value Table C3 = 0.047F C4 = 470pF C5 = See Figure 4 Value Table C6 = 0.47F, 200V (400V) * L = 100H (200H) * R1 = 82 R2 = 1.5M R3 = 10k R4 = 560 (See Note 1) R5 = 10k R6 = 1.8k, 1W (2W) * R7 = 1M to 5M (Select For Sensitivity) R8 = 2.7M (4.7M) * R9 = 100 Z1 = 13V 5%, 1W Z2 = 6.2V, 1/4W (See Note 2) D1 = 1N4148 T = Q4004L4 (Q5004L4) * Typical All resistors 1/4W, all capacitors 25V unless otherwise specified. * Indicates component change for 220VAC Mains. 7310-011697-3 MAXIMUM RATINGS: PARAMETER Storage Temperature Operating Temperature DC Supply Voltage Any Input Voltage DC ELECTRICAL CHARACTERISTICS: (TA = 25C, all voltages referenced to VDD) SYMBOL VSS IDD SYMBOL TSTG TA Vss - VDD VIN VALUE -65 to +150 0 to +80 +20 Vss - 20 to Vss + 0.5 UNIT C C V V Supply Voltage Supply Current Input Voltage: SYNC, LO SYNC, HI All other inputs, LO All other inputs, HI Input Current: SYNC Input MIN +10 - TYP +12 1.2 MAX +14 2 UNIT V mA CONDITION Vss = 12V, outputs off VISL VISH VIL VIH 0 2/3Vss 0 1/2Vss - 1/3Vss Vss 1/4Vss Vss V V V V - IH - - 110 A With Series 1.5M Resistor to 115VAC Input Pull-up Resistance: For LS7310, LS7311 PL, OFF, RUN, PULSE Output Voltage: TRIG, HI TRIG, LO Output Current: TRIG, Sink PL Source RIN 50 100 200 k - VOH VOL Vss - Vss - 8 - V V - IOS IOPL 25 5 - - mA mA Vss = +12V VOL = Vss - 4V VOPL = Vss - 1V DYNAMIC CHARACTERISTICS: SYMBOL SYNC frequency PL,RUN,PULSE,OFF hold time TRIG Pulse Width (LS7310,LS7312) TRIG Pulse Width (LS7311,LS7313) fS TH TH Tw Tw Tw Tw MIN 40 50 60 - TYP 33 39 1.0 1.2 MAX 70 infinite infinite - UNIT Hz ms ms s s ms ms CONDITION 60Hz SYNC 50Hz SYNC 60Hz SYNC 50Hz SYNC 60Hz SYNC 50Hz SYNC The information included herein is believed to be accurate and reliable. However, LSI Computer Systems, Inc. assumes no responsibilities for inaccuracies, nor for any infringements of patent rights of others which may result from its use. 7310-011697-4 |
Price & Availability of LS7313
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |