MCC Features * * * * omponents 21201 Itasca Street Chatsworth !"# $ % !"# MBR2520 THRU MBR25100 25 Amp Schottky Barrier Rectifier 20 to 100 Volts Metal of siliconrectifier, majonty carrier conducton Guard ring for transient protection Low power loss high efficiency High surge capacity, High current capability Maximum Ratings * * Operating Temperature: -55C to +150C Storage Temperature: -55C to +150C Microsemi Catalog Number Device Marking Maximum Recurrent Peak Reverse Voltage 20V 30V 35V 40V 45V 60V 80V 100V Maximum RMS Voltage Maximum DC Blocking Voltage 20V 30V 35V 40V 45V 60V 80V 100V TO-220AC B F Q T A U C S MBR2520 MBR2530 MBR2535 MBR2540 MBR2545 MBR2560 MBR2580 MBR25100 MBR2520 MBR2530 MBR2535 MBR2540 MBR2545 MBR2560 MBR2580 MBR25100 14V 21V 24.5V 28V 31.5 42V 56V 70V H K L D J R Electrical Characteristics @ 25C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element MBR2020-2045 Maximum DC Reverse Current At Rated DC Blocking Voltage IF(AV) 25A TC = 130C G IFSM 150A 8.3ms, half sine A B C D F G H J K L Q R S T U MM 15.11 9.65 4.06 0.64 3.61 4.83 2.79 0.46 12.70 1.14 2.54 2.04 1.14 5.97 ---- 15.75 10.29 4.82 0.89 3.73 5.33 3.30 0.64 14.27 1.52 3.04 2.79 1.39 6.48 1.27 VF MBR2060 MBR2080-20100 .63V .75V .84V IFM = 25A per element; TA = 25C* IR 0.2mA TJ = 25C INCHES .595 .620 .380 .405 .160 .190 .025 .035 .142 .147 .190 .210 .110 .130 .018 .025 .500 .562 .045 .060 .100 .120 .080 .110 .045 .055 .235 .255 -----.050 *Pulse test: Pulse width 300 sec, Duty cycle 1% www.mccsemi.com MBR2520 thru MBR25100 Figure 1 Typical Forward Characteristics 100 60 40 20 MBR2520-2545 10 6 4 2 25C Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .2 .3 .4 .5 .6 .7 .8 MBR2580-25100 .2 TJ=25C Amps .1 .06 .04 .02 .01 .006 .00 4 .002 .001 20 50 75 MBR2560 10 6 4 2 1 .6 .4 MCC Figure 2 Typical Reverse Characteristics 100 Volts 125 150 175 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Forward Derating Curve 25 Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts Figure 4 Peak Forward Surge Current 150 20 125 15 100 75 Amps 8 25 5 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 25 50 75 C Average Forward Rectified Current - Amperes versus Ambient Temperature - C 100 130 150 0 1 4 6 8 10 Cycles Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles 20 40 60 80 100 50 10 Amps 2 www.mccsemi.com |
Price & Availability of MBR2540
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |