![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
ARX5001 & ARX5002 ARX LOW NOISE DC VOLTAGE REGULATORS (Preliminary) Features * Low Noise, 20NV/Hz @10KHz, Typical Low Noise, 20NV/ Hz @10KHz, Typical CIRCUIT TECHNOLOGY www.aeroflex.com * Superior High Frequency Line Built to MIlitary Input Ripple Rejection Full MilitaryTemperature Range, Transient and Standards * Full MilitaryTemperature Range, Built to MIlitary Standards Full MilitaryTemperature Range, Built to MIlitary Standards * State of the Art Power Density, Smallest Possible Surface rea Area of the Art Power Density, Smallest Possible Surface * Load Current Range up to 2 Amperes * Total Worst Case Line & Load Voltage Regulation, < +1% * Internal Short Circuit and Current Fold Back Protection * Available in Standard DC Voltages: +15V & +5V 0.690 0.260 0.118 0.345 0.160 TYP. 0.040 Description The ARX series of low noise DC voltage regulators is a new line of ultra highly reliable microcircuits designed for military and aerospace applications. These regulators utilize advanced multichip module design techniques to provide state-of-the-art performance features with no sacrifice in reliability. The ARX series regulators can be used in applications where minimum size and maximum output power is required. These regulators are designed to operate over the full military operating case temperature range of -55C to +125C. Outstanding high frequency ripple rejection, input overshoot rejection and input noise rejection are features of the ARX series that are not available from monolithic regulators. To provide protection against output overloads, current limiting and reduced current foldback short circuit protection are standard. 0.820 0.535 1 2 3 0.800 TYP 0.070 TYP 0.200 TYP 0.030 0.105+/-.008 Notes: 1. Dimensions in inches 2. Tolerances are +/-0.005 inches unless otherwise specified 3. Package is a JEDEC standard 4. Case is electrically isolated PIN # FUNCTION 1 2 3 VIN VOUT GND PHYSICAL DIMENSIONS (Actual Size) Aeroflex Laboratories Inc. (c) 1995 Table 1 - Electrical Characteristics Part Number (Nominal Voltage) Conditions Parameter (unless otherwise noted) ARX5002 ( +15V ) ARX5001 ( +5V ) TA = -55C to +125C Maximum load current Input Voltage No load current Output Voltage Maximum load current Min 18 14.85 - Nom 15.00 - Max 23 30 15.15 Min 8 4.95 - Nom 5.00 - Max 15 30 5.05 Units VDC VDC VDC Load Current Minimum Input voltage Delta input voltage = 3V Maximum load current Full load to no load current 1.8 50 1.8 10 ADC mVDC mVDC Line Regulation Load Regulation 20 - 1 35 - 100 - 50 Short Circuit Trip Current Minimum Input voltage 2 0.10 0.20 3.5 0.40 2 0.10 0.20 3.5 0.30 ADC ADC Short Circuit Foldback Current Minimum Input voltage Ripple Rejection 0 < f < 150kHz, IL = 900 mA TA= + 25 C, VIN = minimum 10 kHz, IL = 900 mA 40 - - 40 - - dB NV/ Hz Output Spot Noise - - 40 - - 30 Notes : 1. Maximum power dissipation is limited to 10 Watts at 125C case temperature 2. Custom voltage and short circuit trip current settings are available on special order VIN CIN Ceramic 1 F Recomended Wiring Diagram 1 2 ARX5001/ ARX5002 COUT1 3 GND Tantalum 5-10 F Vout COUT2 Ceramic 0.1 F Ordering Information ARX5001 +5 Volts ARX5002 +15 Volts Specifications subject to change without notice. Circuit Technology 35 South Service Road Plainview N.Y. 11803 Tele: (516) 694-6700 Fax: (516) 694-6715 6/23/95 Multichip Modules For The Future |
Price & Availability of ARX5001
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |