RS201 SINGLE PHASE 2.0 AMP BRIDGE RECTIFIERS THRU RS207 VOLTAGE RANGE 50 to 1000 Volts CURRENT 2.0 Amperes RS-2 .510(13.0) .472(12.0) FEATURES * Ideal for printed circuit board * Low forward voltage * Low leakage current * Polarity: marked on body * Mounting position: Any * Weight: 2.74 grams .035(0.9) .028(0.7) DIA. .50 MIN. (12.7) .160(4.1) SPACING .140(3.6) .260(6.5) .240(6.1) .730(18.5) .690(17.5) .125 (3.2) Dimensions in inches and (millimeters) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. TYPE NUMBER Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current .375"(9.5mm) Lead Length at Ta=50 C Peak Forward Surge Current, 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Maximum Forward Voltage Drop per Bridge Element at 1.0A D.C. Maximum DC Reverse Current Ta=25 C at Rated DC Blocking Voltage Operating Temperature Range, TJ Storage Temperature Range, TSTG Ta=100 C RS201 RS202 RS203 RS204 RS205 RS206 50 35 50 100 70 100 200 140 200 400 280 400 2.0 50 1.0 10 -65 -65 500 +125 +150 600 420 600 800 560 800 RS207 UNITS 1000 700 1000 V V V A A V mA mA C C RATING AND CHARACTERISTIC CURVES (RS201 THRU RS207) FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE 1.2 2.0 1.6 1.2 0.8 0.4 0 Single Phase Half Wave 60Hz Resistive Or Inductive Load FIG.2-MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PEAK FORWARD SURGE CURRENT,(A) 50 AVERAGE FORWARD CURRENT,(A) 40 30 Tj=25 C 8.3ms Single Half Sine Wave JEDEC method 20 10 0 25 50 75 100 125 150 175 CASE TEMPERATURE,( C) 0 1 5 10 50 100 NUMBER OF CYCLES AT 60Hz FIG.3-TYPICAL FORWARD CHARACTERISTICS 50 INSTANTANEOUS FORWARD CURRENT,(A) FIG.4-TYPICAL REVERSE CHARACTERISTICS 50 3.0 1.0 Tj=25 C Pulse Width 300us 1% Duty Cycle REVERSE LEAKAGE CURRENT, (mA) 10 10 3.0 1.0 0.1 0.1 Tj=25 C .01 0 .2 .4 .6 .8 1.0 1.2 1.4 .01 0 20 40 60 80 100 120 140 FORWARD VOLT AGE,(V) PERCENT OF RATED PEAK REVERSE VOLT AGE, (%) |
Price & Availability of RS206
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |