|
|
 |
Tektronix
|
Part No. |
80C01 80C02 80C07B 80C08C 80C10 80C11 80C12
|
OCR Text |
...dards or User Defined Rate from 9.8 to 12.6 Gb/s - 80C12 Clock Recovery Available Via 80A05 Clock Recovery Module
40 Gb/s Telecom
- 80C1...953 Gb/s as well as general-purpose testing with up to 20 GHz optical bandwidth. With its clock reco... |
Description |
Optical Sampling Module
|
File Size |
90.45K /
12 Page |
View
it Online |
Download Datasheet
|
|
|
 |

ON Semiconductor
|
Part No. |
NL17SH08P5T5G
|
OCR Text |
...0 1,032,200 117.8 90 419,300 47.9 100 178,700 20.4 110 79,600 9.4 120 37,000 4.2 130 17,800 2.0 140 8,900 1.0 1 1 10 100 1000 time, years no...953 (pb ? free) 8000 / tape & reel ?for information on tape and reel specifications, including part ... |
Description |
Single 2-Input AND Gate
|
File Size |
97.96K /
5 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Matsushita Electric Works(Nais)
|
Part No. |
AEV25012 AEV25024 AEV25112 AEV25124 AEV25312 AEV25324 AEV15012 AEV13012 AEV13024 AEV15112 AEV15024 AEV15124 AEV15312 AEV16012 AEV15324 AEV16024
|
OCR Text |
...d: size includ- ing arc space 1/9 (compared to con- ventional contactors) the arc is not exposed to the outside, therefore, no arc space ...953 .012 m8nut:aev801 .197 1.142 1.339 87.0 14 4-.209 .004 dia 4-5.3 0.1 dia schematic (top vie... |
Description |
EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Indicator contact arrangement: a contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Indicator contact arrangement: a contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Indicator contact arrangement: b contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 2 form A. Contact rating: 150A. Indicator contact arrangement: b contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 30A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 30A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Indicator contact arrangement: a contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Indicator contact arrangement: a contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Indicator contact arrangement: b contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 12 V DC. Contact arrangement: 1 form A. Contact rating: 60A. Without indicator contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 150A. Indicator contact arrangement: b contact. EV-relay. Compact but cut off DC power current, power capsule contact relay. Coil voltage 24 V DC. Contact arrangement: 1 form A. Contact rating: 60A. Without indicator contact.
|
File Size |
215.40K /
6 Page |
View
it Online |
Download Datasheet
|
|

Price and Availability
|